Temperature Transmitter DT 45000 – for Pt, Ni, KTY,TC, R, Potentiometer and mV Sensors, programmable via USB and DIP switch


The programmable Temperature Transmitter DT 45000 is used for measure industrial process signals. It converts Pt, Ni, KTY or TC sensor signals as well as poti, resistor or mV signals on input to isolated standard signals.

  • Universal Measuring Input
    for all common industrial sensor signals
  • Easy configurable via USB or DIP switches
    complete programmable via USB interface or selectable per DIP switch
  • Switchable Service Functions
    Simulation and Teach-In Function for an easy commissioning
  • 3-port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design
    6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector
    allows for fast and economical installation
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

Datasheet
Ex and UL instructions
User Manual

Due to the easy configu­ration via USB inter­face and the cali­brated range selection per DIP switch the Trans­mitter is suitable for flexible use.

The Commissioning Function, switchable on front panel, generates an output refe­rence signal for testing and adjusting of the down­stream signal path. With der Teach-In Function the measuring range limits can be set during operation.

With the USB Programming-Kit DRAGOset the Trans­mitter can be confi­gured and all data can be stored by a PC. In mode of programming no additio­nally auxiliary power is required.

The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. The status of power supply and sensor connection will be displayed by a LED on front.

Product line

Device Type Order No.
Temperature Transmitter, programmable via USB and DIP switch DT 45000 S
Temperature Transmitter, programmable via USB and DIP switch,
In-Rail-Bus for power supply
DT 45000 B

 

Technical Data

Input

Sensor Type Span min. Measuring error
Pt Pt100, Pt200, Pt500, Pt1000 10 K <0.1K+0.05% meas.val.
Ni Ni100, Ni200, Ni500, Ni1000 10 K <0.1K+0.05% meas.val.
KTY KTY, 29 types 25 K <0.3K+0.05% meas.val.
Resistor 0 to 5000 Ohm 20 Ohm <0.1Ω+0.02% meas.val.
   Sensor current / conn. 0.2 mA / 4-wire, 3-wire, 2-wire
   Cable resistance < 100 Ohm per wire, manual compensation for 2-wire connection programmable
Thermocouples E, J, K, L, N, R, S, T, U
B, C, D
50K
100K
<0.3K+0.08% meas.val.
<0.3K+0.08% meas.val.
   Cold junction comp. internal, external, uncompensated, manual setting Error of Cold junction internal < 1.5 K
mV Input ±100 mV, ±1000 mV 5mV/50mV <50µV+0.05% meas.val.
Potentiometer 100 Ohm to 50 kOhm 10 %

Output

Current Voltage
Output signal 0 to 20mA, 4 to 20mA, 0 to 10mA, 2 to 10mA 0 to 5V, 0 to 10V, 1 to 5V, 2 to 10V
Load ≤ 12 V   (600 Ohm @ 20 mA) ≤ 5 mA   (2 kOhm @ 10 V)
Residual ripple < 10 mVrms
transfer range 0 to 102.5 %  (3.8 to 20.5 mA at output 4 to 20 mA) Transfer characteristic rising/falling
Error signal Sensor/wire break, error signal programmable

General Data

Transmission error < 0.1 % full scale
Temperature coefficient1) < 100 ppm/K
Sampling rate 4/s
Response time T99 250 ms
Test voltage 3 kV AC, 50 Hz, 1 min Input against output against power supply
Working voltage 2)
(basic insulation)
600 V AC/DC for overvoltage category II and pollution
degree 2 acc. to EN 61010-1
Protection against
electric shock 2)
Protective Separation by reinforced insulation acc. to EN 61010-1
up to 300 V AC/DC for overvoltage category II and contamination
class 2 between input and output and power supply.
Ambient temperature Operation
Transport and storage
-25 °C to +70 °C
-40 °C to +85 °C
(-13 to +158 °F)
(-40 to +185 °F)
Power supply 24 V DC, voltage range 9.6 V to 31.2 V DC, approx. 0.8 W
EMC 3) EN 61326-1
Approvals UL (USA/Canada): UL 61010, Class I, Div. 2
ATEX / IECEx: Zone 2 (nA)
Construction 6.2 mm (0.244″) housing, protection type: IP 20
mounting on 35 mm DIN rail acc. to EN 60715
Connection Captive plus-minus clamp screws
Wire cross-section max. 2.5 mm² / AWG 14
Stripped length 6 to 8 mm / 0.28 in
Screw terminal torque 0.8 Nm / 7 lbf in
Weight Approx. 70 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • 1Input
  • 2Input
  • 3Input
  • 4Input
  • 5 +Output
  • 6 −Output
  • 7 +Power supply 24 V DC
    (connected to In-Rail-Bus)
  • 8 −Power supply 24 V DC
    (connected to In-Rail-Bus)

Optional power connection via In-Rail-Bus (see accessories)









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Temperature Transmitter DT 45000 – for Pt, Ni, KTY,TC, R, Potentiometer and mV Sensors, programmable via USB and DIP switch

    The programmable Temperature Transmitter DT 45000 is used for measure industrial process signals. It converts Pt, Ni, KTY or TC sensor signals as well as poti, resistor or mV signals on input to isolated standard signals.

    • Universal Measuring Input
      for all common industrial sensor signals
    • Easy configurable via USB or DIP switches
      complete programmable via USB interface or selectable per DIP switch
    • Switchable Service Functions
      Simulation and Teach-In Function for an easy commissioning
    • 3-port isolation
      Protection against erroneous measurements due to parasitic voltages or ground loops
    • Extremely slim design
      6.2 mm slim housing for a simple and space saving DIN rail mounting
    • Optional In-Rail-Bus mounting rail connector
      allows for fast and economical installation
    • Protective Separation acc. to EN 61140
      Protects service personnel and downstream devices against impermissibly high voltage
    • 5 Years Warranty
      Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

    Datasheet
    Ex and UL instructions
    User Manual

    Due to the easy configu­ration via USB inter­face and the cali­brated range selection per DIP switch the Trans­mitter is suitable for flexible use.

    The Commissioning Function, switchable on front panel, generates an output refe­rence signal for testing and adjusting of the down­stream signal path. With der Teach-In Function the measuring range limits can be set during operation.

    With the USB Programming-Kit DRAGOset the Trans­mitter can be confi­gured and all data can be stored by a PC. In mode of programming no additio­nally auxiliary power is required.

    The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. The status of power supply and sensor connection will be displayed by a LED on front.

    Product line

    Device Type Order No.
    Temperature Transmitter, programmable via USB and DIP switch DT 45000 S
    Temperature Transmitter, programmable via USB and DIP switch,
    In-Rail-Bus for power supply
    DT 45000 B

     

    Technical Data

    Input

    Sensor Type Span min. Measuring error
    Pt Pt100, Pt200, Pt500, Pt1000 10 K <0.1K+0.05% meas.val.
    Ni Ni100, Ni200, Ni500, Ni1000 10 K <0.1K+0.05% meas.val.
    KTY KTY, 29 types 25 K <0.3K+0.05% meas.val.
    Resistor 0 to 5000 Ohm 20 Ohm <0.1Ω+0.02% meas.val.
       Sensor current / conn. 0.2 mA / 4-wire, 3-wire, 2-wire
       Cable resistance < 100 Ohm per wire, manual compensation for 2-wire connection programmable
    Thermocouples E, J, K, L, N, R, S, T, U
    B, C, D
    50K
    100K
    <0.3K+0.08% meas.val.
    <0.3K+0.08% meas.val.
       Cold junction comp. internal, external, uncompensated, manual setting Error of Cold junction internal < 1.5 K
    mV Input ±100 mV, ±1000 mV 5mV/50mV <50µV+0.05% meas.val.
    Potentiometer 100 Ohm to 50 kOhm 10 %

    Output

    Current Voltage
    Output signal 0 to 20mA, 4 to 20mA, 0 to 10mA, 2 to 10mA 0 to 5V, 0 to 10V, 1 to 5V, 2 to 10V
    Load ≤ 12 V   (600 Ohm @ 20 mA) ≤ 5 mA   (2 kOhm @ 10 V)
    Residual ripple < 10 mVrms
    transfer range 0 to 102.5 %  (3.8 to 20.5 mA at output 4 to 20 mA) Transfer characteristic rising/falling
    Error signal Sensor/wire break, error signal programmable

    General Data

    Transmission error < 0.1 % full scale
    Temperature coefficient1) < 100 ppm/K
    Sampling rate 4/s
    Response time T99 250 ms
    Test voltage 3 kV AC, 50 Hz, 1 min Input against output against power supply
    Working voltage 2)
    (basic insulation)
    600 V AC/DC for overvoltage category II and pollution
    degree 2 acc. to EN 61010-1
    Protection against
    electric shock 2)
    Protective Separation by reinforced insulation acc. to EN 61010-1
    up to 300 V AC/DC for overvoltage category II and contamination
    class 2 between input and output and power supply.
    Ambient temperature Operation
    Transport and storage
    -25 °C to +70 °C
    -40 °C to +85 °C
    (-13 to +158 °F)
    (-40 to +185 °F)
    Power supply 24 V DC, voltage range 9.6 V to 31.2 V DC, approx. 0.8 W
    EMC 3) EN 61326-1
    Approvals UL (USA/Canada): UL 61010, Class I, Div. 2
    ATEX / IECEx: Zone 2 (nA)
    Construction 6.2 mm (0.244″) housing, protection type: IP 20
    mounting on 35 mm DIN rail acc. to EN 60715
    Connection Captive plus-minus clamp screws
    Wire cross-section max. 2.5 mm² / AWG 14
    Stripped length 6 to 8 mm / 0.28 in
    Screw terminal torque 0.8 Nm / 7 lbf in
    Weight Approx. 70 g
    1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
    2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
    3. Minor deviations possible during interference

    Block diagram

    Dimensions

    Terminal assignments

    • 1Input
    • 2Input
    • 3Input
    • 4Input
    • 5 +Output
    • 6 −Output
    • 7 +Power supply 24 V DC
      (connected to In-Rail-Bus)
    • 8 −Power supply 24 V DC
      (connected to In-Rail-Bus)

    Optional power connection via In-Rail-Bus (see accessories)









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.