Thermocouple Transmitter DT 45800 – Temperature Measuring with Thermocouple Sensors, configurable via DIP Switch or USB


The TC Temperature Transmitter DT 45800 is used for measure industrial process signals. It converts Thermocouple sensor signals to isolated standard signals.

  • Measuring input for all TC temperature sensors
    more than 1800 standard ranges ready to use
  • Easy configurable via DIP switches
    or via USB interface without auxiliary power supply
  • Switchable Service Functions
    for an easy commissioning
  • 3-port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design
    6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Optional In-Rail-Bus mounting rail connector
    allows for fast and economical installation
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

Datasheet
Ex and UL instructions
User Manual

Due to the easy setting of the calibrated measuring ranges via DIP switch the Transmitter is suitable for flexible use.

With the USB Programming-Kit DRAGOset the Transmitter can be configured and all data can be stored by a PC. In mode of programming no additionally auxiliary power is required.

The Commissioning Function, switchable on front panel, generates an output reference signal for testing and adjusting of the downstream signal path.

The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. The status of power supply and sensor connection will be displayed by a LED on front.

Product line

Device Type Order No.
TC Temperature Transmitter,
programmable via USB and DIP switch
DT 45800 S
TC Temperature Transmitter,
programmable via USB and DIP switch, In-Rail-Bus for power supply
DT 45800 B

 

Technical Data

Input

Sensor
Thermocouple Sensor Standard Measuring range Span min.
Type K NiCr-Ni IEC 584 -200 to 1350 °C 50 K
Type J Fe-CuNi IEC 584 -200 to 1200 °C 50 K
Type A W5Re-W20Re GOST 8.585 0 to 2500 °C 100 K
Type B Pt30Rh-Pt6Rh IEC 584 +250 to 1800 °C 100 K
Type C W5Re-W26Re ASTM E988 0 to 2300 °C 100 K
Type D W3Re-W25Re ASTM E988 0 to 2300 °C 100 K
Type E NiCr-CuNi IEC 584 -200 to 1000 °C 50 K
Type L Fe-CuNi DIN 43710 -200 to 900 °C 50 K
Type N NiCrSi-NiSi IEC 584 -200 to 1300 °C 50 K
Type R Pt13Rh-Pt IEC 584 -50 to 1700 °C 50 K
Type S Pt10Rh-Pt IEC 584 -50 to 1700 °C 50 K
Type T Cu-CuNi IEC 584 -200 to 400 °C 50 K
Type U Cu-CuNi DIN 43710 -200 to 600 °C 50 K
Measuring error < 0.3 K + 0.08 % meas. val.
Cold junction
compensation
Internal / OFF, Error of Cold junction < 1.5 K

Output

Current Voltage
Output signal 0 to 20mA, 4 to 20mA 0 to 5V, 0 to 10V
Load ≤ 12 V   (600 Ohm @ 20 mA) ≤ 5 mA   (2 kOhm @ 10 V)
Residual ripple < 10 mVrms
transfer range 0 to 102.5 %  (3.8 to 20.5 mA at output 4 to 20 mA) Transfer characteristic rising/falling
Error signal Sensor/wire break, error signal programmable

General Data

Transmission error < 0.1 % full scale
Temperature coefficient1) < 100 ppm/K
Sampling rate 4/s
Response time T99 250 ms
Test voltage 3 kV AC, 50 Hz, 1 min Input against output against power supply
Working voltage 2)
(basic insulation)
600 V AC/DC for overvoltage category II and pollution
degree 2 acc. to EN 61010-1
Protection against
electric shock 2)
Protective Separation by reinforced insulation acc. to EN 61010-1
up to 300 V AC/DC for overvoltage category II and contamination
class 2 between input and output and power supply.
Ambient temperature Operation
Transport and storage
-25 °C to +70 °C
-40 °C to +85 °C
(-13 to +158 °F)
(-40 to +185 °F)
Power supply 24 V DC, voltage range 9.6 V to 31.2 V DC, approx. 0.8 W
EMC 3) EN 61326-1
Approvals UL (USA/Canada): UL 61010, Class I, Div. 2
ATEX / IECEx: Zone 2 (nA)
Construction 6.2 mm (0.244″) housing, protection type: IP 20
mounting on 35 mm DIN rail acc. to EN 60715
Connection Captive plus-minus clamp screws
Wire cross-section max. 2.5 mm² / AWG 14
Stripped length 6 to 8 mm / 0.28 in
Screw terminal torque 0.8 Nm / 7 lbf in
Weight Approx. 70 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • 1
  • 2 +Input TC
  • 3 −Input TC
  • 4
  • 5 +Output
  • 6 −Output
  • 7 +Power supply 24 V DC
    (connected to In-Rail-Bus)
  • 8 −Power supply 24 V DC
    (connected to In-Rail-Bus)

Optional power connection via In-Rail-Bus (see accessories)









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Thermocouple Transmitter DT 45800 – Temperature Measuring with Thermocouple Sensors, configurable via DIP Switch or USB

    The TC Temperature Transmitter DT 45800 is used for measure industrial process signals. It converts Thermocouple sensor signals to isolated standard signals.

    • Measuring input for all TC temperature sensors
      more than 1800 standard ranges ready to use
    • Easy configurable via DIP switches
      or via USB interface without auxiliary power supply
    • Switchable Service Functions
      for an easy commissioning
    • 3-port isolation
      Protection against erroneous measurements due to parasitic voltages or ground loops
    • Extremely slim design
      6.2 mm slim housing for a simple and space saving DIN rail mounting
    • Optional In-Rail-Bus mounting rail connector
      allows for fast and economical installation
    • Protective Separation acc. to EN 61140
      Protects service personnel and downstream devices against impermissibly high voltage
    • 5 Years Warranty
      Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)

    Datasheet
    Ex and UL instructions
    User Manual

    Due to the easy setting of the calibrated measuring ranges via DIP switch the Transmitter is suitable for flexible use.

    With the USB Programming-Kit DRAGOset the Transmitter can be configured and all data can be stored by a PC. In mode of programming no additionally auxiliary power is required.

    The Commissioning Function, switchable on front panel, generates an output reference signal for testing and adjusting of the downstream signal path.

    The auxiliary power can be supplied via the connection terminals or via the optional In-Rail-Bus connector. The status of power supply and sensor connection will be displayed by a LED on front.

    Product line

    Device Type Order No.
    TC Temperature Transmitter,
    programmable via USB and DIP switch
    DT 45800 S
    TC Temperature Transmitter,
    programmable via USB and DIP switch, In-Rail-Bus for power supply
    DT 45800 B

     

    Technical Data

    Input

    Sensor
    Thermocouple Sensor Standard Measuring range Span min.
    Type K NiCr-Ni IEC 584 -200 to 1350 °C 50 K
    Type J Fe-CuNi IEC 584 -200 to 1200 °C 50 K
    Type A W5Re-W20Re GOST 8.585 0 to 2500 °C 100 K
    Type B Pt30Rh-Pt6Rh IEC 584 +250 to 1800 °C 100 K
    Type C W5Re-W26Re ASTM E988 0 to 2300 °C 100 K
    Type D W3Re-W25Re ASTM E988 0 to 2300 °C 100 K
    Type E NiCr-CuNi IEC 584 -200 to 1000 °C 50 K
    Type L Fe-CuNi DIN 43710 -200 to 900 °C 50 K
    Type N NiCrSi-NiSi IEC 584 -200 to 1300 °C 50 K
    Type R Pt13Rh-Pt IEC 584 -50 to 1700 °C 50 K
    Type S Pt10Rh-Pt IEC 584 -50 to 1700 °C 50 K
    Type T Cu-CuNi IEC 584 -200 to 400 °C 50 K
    Type U Cu-CuNi DIN 43710 -200 to 600 °C 50 K
    Measuring error < 0.3 K + 0.08 % meas. val.
    Cold junction
    compensation
    Internal / OFF, Error of Cold junction < 1.5 K

    Output

    Current Voltage
    Output signal 0 to 20mA, 4 to 20mA 0 to 5V, 0 to 10V
    Load ≤ 12 V   (600 Ohm @ 20 mA) ≤ 5 mA   (2 kOhm @ 10 V)
    Residual ripple < 10 mVrms
    transfer range 0 to 102.5 %  (3.8 to 20.5 mA at output 4 to 20 mA) Transfer characteristic rising/falling
    Error signal Sensor/wire break, error signal programmable

    General Data

    Transmission error < 0.1 % full scale
    Temperature coefficient1) < 100 ppm/K
    Sampling rate 4/s
    Response time T99 250 ms
    Test voltage 3 kV AC, 50 Hz, 1 min Input against output against power supply
    Working voltage 2)
    (basic insulation)
    600 V AC/DC for overvoltage category II and pollution
    degree 2 acc. to EN 61010-1
    Protection against
    electric shock 2)
    Protective Separation by reinforced insulation acc. to EN 61010-1
    up to 300 V AC/DC for overvoltage category II and contamination
    class 2 between input and output and power supply.
    Ambient temperature Operation
    Transport and storage
    -25 °C to +70 °C
    -40 °C to +85 °C
    (-13 to +158 °F)
    (-40 to +185 °F)
    Power supply 24 V DC, voltage range 9.6 V to 31.2 V DC, approx. 0.8 W
    EMC 3) EN 61326-1
    Approvals UL (USA/Canada): UL 61010, Class I, Div. 2
    ATEX / IECEx: Zone 2 (nA)
    Construction 6.2 mm (0.244″) housing, protection type: IP 20
    mounting on 35 mm DIN rail acc. to EN 60715
    Connection Captive plus-minus clamp screws
    Wire cross-section max. 2.5 mm² / AWG 14
    Stripped length 6 to 8 mm / 0.28 in
    Screw terminal torque 0.8 Nm / 7 lbf in
    Weight Approx. 70 g
    1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
    2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
    3. Minor deviations possible during interference

    Block diagram

    Dimensions

    Terminal assignments

    • 1
    • 2 +Input TC
    • 3 −Input TC
    • 4
    • 5 +Output
    • 6 −Output
    • 7 +Power supply 24 V DC
      (connected to In-Rail-Bus)
    • 8 −Power supply 24 V DC
      (connected to In-Rail-Bus)

    Optional power connection via In-Rail-Bus (see accessories)









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.