EMT422-2 / EMT462-2 – measuring pressure transmitter

No longer available. This product is no longer offered.
Recommended alternative: SPX 4222

  • Intrinsically safe EMT4XX 2 melt pressure transmitter for pressure and temperature measurement
  • ATEX-certified for hazardous area applications
  • Integrated Type J thermocouple for simultaneous temperature measurement
  • PTB-approved 4–20 mA two-wire output
  • Pressure ranges from 0–17 bar to 0–2,000 bar
  • Media temperatures up to 400 °C
  • Flexible capillary connection between sensing stem and electronics housing

Datasheet
Videos

Dynisco EMT4XX 2 Intrinsically Safe Melt Pressure Transmitter with Integrated Thermocouple

The EMT4XX 2 series is based on Dynisco’s proven TDT technology and has been specifically developed for pressure measurement in hazardous areas. The PTB-approved two-wire amplifier converts process pressure into a proportional 4–20 mA output signal, ensuring reliable and noise-free signal transmission even over long cable distances.

An integrated Type J thermocouple allows simultaneous pressure and temperature measurement directly at the process medium. The flexible connection between the sensing stem and electronics housing improves thermal isolation and protects the electronics from excessive process heat. The series also features a flush diaphragm, integrated electronic calibration functionality and ATEX certification for use in Zone 1 and Zone 2 hazardous environments.

Technical Specifications
Pressure Ranges 0–17 bar to 0–2,000 bar
Temperature Measurement Integrated Type J thermocouple
Accuracy EMT432 2 ±0.5% FSO (up to 50 bar ±1% FSO)
Accuracy EMT463 2 ±1% FSO
Repeatability EMT432 2 ±0.1% FSO (up to 50 bar ±0.2% FSO)
Repeatability EMT463 2 ±0.2% FSO
Resolution Infinite
Maximum Overpressure 2× pressure range; for 1,000 and 1,400 bar ranges max. 1,750 bar; for 2,000 bar range max. 2,450 bar
Burst Pressure 6× pressure range, max. 3,000 bar
Wetted Material 15-5 PH stainless steel (1.4545), DyMax™ coated
Sensing Element Four-arm strain gauge bridge
Output Signal 4–20 mA
Supply Voltage 15–28 VDC
Current Consumption < 20 mA
Zero Adjustment -2% to +10% of full scale
Internal Calibration Point 80% of full scale ±10%
Load Resistance 750 Ω at 28 VDC, 145 Ω at 15 VDC
Insulation Resistance 1,000 MΩ at 50 VDC
Maximum Diaphragm Temperature 400 °C
Maximum Housing Temperature 80 °C (T1–T4), 75 °C (T5)
Diaphragm Zero Shift EMT432 2: ±0.2 bar / 10 °C
EMT463 2: ±0.4 bar / 10 °C
Sensitivity Shift EMT432 2: ±0.1% FS/10 °C (up to 50 bar ±0.2% FS/10 °C)
EMT463 2: ±0.4% FS/10 °C
ATEX Approval II2G EEx ia IIC T5 up to 75 °C and II2G EEx ia IIC T1-T4 up to 80 °C





More documents




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    EMT422-2 / EMT462-2 – measuring pressure transmitter

    No longer available. This product is no longer offered.
    Recommended alternative: SPX 4222
    • Intrinsically safe EMT4XX 2 melt pressure transmitter for pressure and temperature measurement
    • ATEX-certified for hazardous area applications
    • Integrated Type J thermocouple for simultaneous temperature measurement
    • PTB-approved 4–20 mA two-wire output
    • Pressure ranges from 0–17 bar to 0–2,000 bar
    • Media temperatures up to 400 °C
    • Flexible capillary connection between sensing stem and electronics housing

    Datasheet
    Videos

    Dynisco EMT4XX 2 Intrinsically Safe Melt Pressure Transmitter with Integrated Thermocouple

    The EMT4XX 2 series is based on Dynisco’s proven TDT technology and has been specifically developed for pressure measurement in hazardous areas. The PTB-approved two-wire amplifier converts process pressure into a proportional 4–20 mA output signal, ensuring reliable and noise-free signal transmission even over long cable distances.

    An integrated Type J thermocouple allows simultaneous pressure and temperature measurement directly at the process medium. The flexible connection between the sensing stem and electronics housing improves thermal isolation and protects the electronics from excessive process heat. The series also features a flush diaphragm, integrated electronic calibration functionality and ATEX certification for use in Zone 1 and Zone 2 hazardous environments.

    Technical Specifications
    Pressure Ranges 0–17 bar to 0–2,000 bar
    Temperature Measurement Integrated Type J thermocouple
    Accuracy EMT432 2 ±0.5% FSO (up to 50 bar ±1% FSO)
    Accuracy EMT463 2 ±1% FSO
    Repeatability EMT432 2 ±0.1% FSO (up to 50 bar ±0.2% FSO)
    Repeatability EMT463 2 ±0.2% FSO
    Resolution Infinite
    Maximum Overpressure 2× pressure range; for 1,000 and 1,400 bar ranges max. 1,750 bar; for 2,000 bar range max. 2,450 bar
    Burst Pressure 6× pressure range, max. 3,000 bar
    Wetted Material 15-5 PH stainless steel (1.4545), DyMax™ coated
    Sensing Element Four-arm strain gauge bridge
    Output Signal 4–20 mA
    Supply Voltage 15–28 VDC
    Current Consumption < 20 mA
    Zero Adjustment -2% to +10% of full scale
    Internal Calibration Point 80% of full scale ±10%
    Load Resistance 750 Ω at 28 VDC, 145 Ω at 15 VDC
    Insulation Resistance 1,000 MΩ at 50 VDC
    Maximum Diaphragm Temperature 400 °C
    Maximum Housing Temperature 80 °C (T1–T4), 75 °C (T5)
    Diaphragm Zero Shift EMT432 2: ±0.2 bar / 10 °C
    EMT463 2: ±0.4 bar / 10 °C
    Sensitivity Shift EMT432 2: ±0.1% FS/10 °C (up to 50 bar ±0.2% FS/10 °C)
    EMT463 2: ±0.4% FS/10 °C
    ATEX Approval II2G EEx ia IIC T5 up to 75 °C and II2G EEx ia IIC T1-T4 up to 80 °C





    More documents




    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.