RTD Temperature Monitor DG 3602 / DG 3632 – Limit Monitoring with Pt, Ni, KTY and NTC Sensors


The Tempera­ture Monitors DG 3602 and DG 3632 are used for tempera­ture control with RTD sensors in 2-wire connec­tion.

  • Easy configuration on front panel
    Measuring range and operating mode switchable, switch point and hysteresis adjustable with potentiometer
  • Status indication by LED
    Easy monitoring and switching point adjustment
  • Relay contacts with high power handling
    2 fully isolated changeover contacts
  • True 4-port separation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Protective Separation acc. to EN 61010
    Protects service personnel and downstream devices against impermissibly high voltage
  • High reliability and noise immunity
    No microprocessor, no integrated software
  • Extremely slim design
    12.5 mm slim housing for a simple and space saving DIN rail mounting
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant
Datasheett
User Manual

The sensor signal will be com­pared with the set limit values. In case of over­shoo­ting or under­shoo­ting, the output relays react according to the set confi­guration.

Two relay outputs (synchro­nous switching) can be confi­gured as MIN or MAX alarm in open-circuit or close­dcircuit opera­tion with the analog control electronics.

All setting elements are located behind the open­able front cover and can also be opera­ted when the unit is mounted. The switching points and the switching hyste­resis can be
adjusted with poten­tio­meters. The monitoring states are indicated by yellow LEDs.

The relay change­over contacts switch high power loads up to 6 A. Input, power supply and the outputs are safely galvani­cally isolated from each other.

The Pro­tective Sepa­ration and the 24 V DC power supply make the DG 3602 and DG 3632 uni­ver­sally appli­cable for all measure­ment and industrial appli­cations, as well as for building auto­mation.

Product line

Device Order No.
Temperature Monitor for low impedance sensors DG 3602
Temperature Monitor for high impedance sensors DG 3632

 

Technical Data

Input

DG 3602 DG 3632
Input ranges (switchable) 0 … 300 Ω / 0 … 3 kΩ 0 … 30 kΩ / 0 … 300 kΩ
Monitoring sensors Pt100, Pt200, Pt500, Pt1000,
Ni100, Ni120, Ni500, Ni1000,
KTY and further RTD
NTC
Further high impedance RTD
Sensor current ≤ 1.5 mA / 0.15 mA ≤ 0.2 mA / 0.02 mA
Sensor connection 2-wire sensor connection, manual compensation of line resistances required
Switch point setting 0 to 110 % with 12-turn potentiometer
Hysteresis setting 0 to 6 % or 0 to 60 % of measuring range switchable, adjustable with potentiometer

Output

Contact type 2 isolated changeover relays (SPDT), synchronous switching
Switching capability AC max. 250 V / 6 A,     1500 VA
Switching capability DC max. 250 V / 0.2 A,    115 V / 0.3 A,     30 V / 6 A
Recommended minimum load 300 mW / 5 V / 5 mA
Status indication yellow LED
Response time < 50 ms

General Data

Switch error < 0.2 % full scale
Temperature coefficient 1) < 150 ppm/K
Test voltage 4 kV AC, 50 Hz, 1 min. input against power supply against both switching outputs
3 kV AC, 50 Hz, 1 min.  switching output 1 against switching output 2
Working voltage
(Basic Insulation) 2)
1000 V AC/DC for overvoltage category II and 600 V AC/DC for overvoltage category III according to DIN EN 61010 with pollution degree 2 between input, power supply and both switching outputs. Furthermore 300 V AC/DC between output 1 and output 2.
Protection against electrical shock 2) Protective separation according to DIN EN 61140 by reinforced insulation according to DIN EN 61010 up to 600 V AC/DC at overvoltage category II and 300 V AC/DC at overvoltage category III at pollution degree 2 between input, power supply and both switching outputs.
Furthermore 300 V AC/DC between output 1 and output 2.
Power supply 24 V DC,   15 %, approx. 0.7 W
Ambient temperature Operation
Transport and storage
–20 °C to +60 °C    (-4 to +140 °F)
–35 °C to +85 °C    (-31 to +185 °F)
EMC 3) EN 61326 -1
MTBF (acc. to EN 61709 / SN 29500) 297.1 years (Tamb. 40 °C, FIT 383.9)
Construction 12.5 mm (0.5″) housing, protection class IP 20, mounting on 35 mm DIN rail acc. to EN 60715
Connection Captive plus-minus clamp screws, Wire cross-section max. 2.5 mm² / AWG 14
Stripped length 6 … 8 mm / 0.28 in, Screw terminal torque 0.8 Nm / 7 lbf in
Weight 70 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • 1.1 +Power supply +
  • 1.2 −Power supply −
  • 3.1Input RTD
  • 3.2Input RTD
  • Output 1
  • 4.1COM
  • 4.2NO
  • 5.1NC
  • Output 2
  • 6.1COM
  • 6.2NO
  • 5.2NC

Do not connect terminal 2.1 and 2.2









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    RTD Temperature Monitor DG 3602 / DG 3632 – Limit Monitoring with Pt, Ni, KTY and NTC Sensors

    The Tempera­ture Monitors DG 3602 and DG 3632 are used for tempera­ture control with RTD sensors in 2-wire connec­tion.

    • Easy configuration on front panel
      Measuring range and operating mode switchable, switch point and hysteresis adjustable with potentiometer
    • Status indication by LED
      Easy monitoring and switching point adjustment
    • Relay contacts with high power handling
      2 fully isolated changeover contacts
    • True 4-port separation
      Protection against erroneous measurements due to parasitic voltages or ground loops
    • Protective Separation acc. to EN 61010
      Protects service personnel and downstream devices against impermissibly high voltage
    • High reliability and noise immunity
      No microprocessor, no integrated software
    • Extremely slim design
      12.5 mm slim housing for a simple and space saving DIN rail mounting
    • 5 Years Warranty
      Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant
    Datasheett
    User Manual

    The sensor signal will be com­pared with the set limit values. In case of over­shoo­ting or under­shoo­ting, the output relays react according to the set confi­guration.

    Two relay outputs (synchro­nous switching) can be confi­gured as MIN or MAX alarm in open-circuit or close­dcircuit opera­tion with the analog control electronics.

    All setting elements are located behind the open­able front cover and can also be opera­ted when the unit is mounted. The switching points and the switching hyste­resis can be
    adjusted with poten­tio­meters. The monitoring states are indicated by yellow LEDs.

    The relay change­over contacts switch high power loads up to 6 A. Input, power supply and the outputs are safely galvani­cally isolated from each other.

    The Pro­tective Sepa­ration and the 24 V DC power supply make the DG 3602 and DG 3632 uni­ver­sally appli­cable for all measure­ment and industrial appli­cations, as well as for building auto­mation.

    Product line

    Device Order No.
    Temperature Monitor for low impedance sensors DG 3602
    Temperature Monitor for high impedance sensors DG 3632

     

    Technical Data

    Input

    DG 3602 DG 3632
    Input ranges (switchable) 0 … 300 Ω / 0 … 3 kΩ 0 … 30 kΩ / 0 … 300 kΩ
    Monitoring sensors Pt100, Pt200, Pt500, Pt1000,
    Ni100, Ni120, Ni500, Ni1000,
    KTY and further RTD
    NTC
    Further high impedance RTD
    Sensor current ≤ 1.5 mA / 0.15 mA ≤ 0.2 mA / 0.02 mA
    Sensor connection 2-wire sensor connection, manual compensation of line resistances required
    Switch point setting 0 to 110 % with 12-turn potentiometer
    Hysteresis setting 0 to 6 % or 0 to 60 % of measuring range switchable, adjustable with potentiometer

    Output

    Contact type 2 isolated changeover relays (SPDT), synchronous switching
    Switching capability AC max. 250 V / 6 A,     1500 VA
    Switching capability DC max. 250 V / 0.2 A,    115 V / 0.3 A,     30 V / 6 A
    Recommended minimum load 300 mW / 5 V / 5 mA
    Status indication yellow LED
    Response time < 50 ms

    General Data

    Switch error < 0.2 % full scale
    Temperature coefficient 1) < 150 ppm/K
    Test voltage 4 kV AC, 50 Hz, 1 min. input against power supply against both switching outputs
    3 kV AC, 50 Hz, 1 min.  switching output 1 against switching output 2
    Working voltage
    (Basic Insulation) 2)
    1000 V AC/DC for overvoltage category II and 600 V AC/DC for overvoltage category III according to DIN EN 61010 with pollution degree 2 between input, power supply and both switching outputs. Furthermore 300 V AC/DC between output 1 and output 2.
    Protection against electrical shock 2) Protective separation according to DIN EN 61140 by reinforced insulation according to DIN EN 61010 up to 600 V AC/DC at overvoltage category II and 300 V AC/DC at overvoltage category III at pollution degree 2 between input, power supply and both switching outputs.
    Furthermore 300 V AC/DC between output 1 and output 2.
    Power supply 24 V DC,   15 %, approx. 0.7 W
    Ambient temperature Operation
    Transport and storage
    –20 °C to +60 °C    (-4 to +140 °F)
    –35 °C to +85 °C    (-31 to +185 °F)
    EMC 3) EN 61326 -1
    MTBF (acc. to EN 61709 / SN 29500) 297.1 years (Tamb. 40 °C, FIT 383.9)
    Construction 12.5 mm (0.5″) housing, protection class IP 20, mounting on 35 mm DIN rail acc. to EN 60715
    Connection Captive plus-minus clamp screws, Wire cross-section max. 2.5 mm² / AWG 14
    Stripped length 6 … 8 mm / 0.28 in, Screw terminal torque 0.8 Nm / 7 lbf in
    Weight 70 g
    1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
    2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks
    3. Minor deviations possible during interference

    Block diagram

    Dimensions

    Terminal assignments

    • 1.1 +Power supply +
    • 1.2 −Power supply −
    • 3.1Input RTD
    • 3.2Input RTD
    • Output 1
    • 4.1COM
    • 4.2NO
    • 5.1NC
    • Output 2
    • 6.1COM
    • 6.2NO
    • 5.2NC

    Do not connect terminal 2.1 and 2.2









    Technical advice: 03303 / 50 40 66