Additel 221A Multifunction Temperature Calibrator

No longer available. This product is no longer offered.
Recommended alternative: Additel ADT209 / ADT210 Series Loop Calibrator

  • Sourcing, simulating and measuring, temperature and electrical signals
  • Smartphone-like menu and interface make the operation simpler and easier
  • The internal cold junction compensation sensor can be re-calibrated  at ice point by users
  • Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)
  • ISO 17025-accredited calibration w/data included
Datasheet

A highly integrated Multifunction Temperature Calibrator featuring several patented technologies, the 221A is an ultra-compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring temperature, and electrical signals. Its smartphone-like menu and interface make the operation simpler and easier. The 221A is ideal for calibrating, maintaining, and troubleshooting process instrumentations. Automation and documentation capabilities make the 221A a turnkey solution.

Sourcing, simulating and measuring temperature and electrical
signals
Sources and measures mV, mA, ohms, RTDs,
thermocouples, frequency, and pulses
Simulates and measures 13 thermocouples and 11
RTDs to calibrate transmitters
Measures and sources pressure using Additel 160A
series Intelligent Digital Pressure Modules from -15 psi
to 10,000 psi (-1 bar to 700 bar)
24V loop power supply
Simultaneous dual reading capability
Automatic switch test
Supports square root transmitter
Pulse frequency output for the calibration of flow totalizer

Easy to use
Smartphone-like menu and interface make the operation
simpler and easier
Ultra-compact, size 3.9″ x 7.6″ x 2.0″ (100mm x 192mm
x 52mm), and weight 1.6 lb (0.7 kg)
One handed operation

 

Calibrated cold junction compensation (Patented)
Cold junction equalizing block in the calibrator
A calibrated PRT element with flexible leads is
installed
in the equalizing block for thermocouple cold junction
compensation
This PRT element can be pulled out from the calibrator
and re-calibrated and corrected at the ice point

Documenting and automated procedure capability
Manage the information of the device under test.
Set up automated calibration procedures, and 223A
performs the test, calculates the errors, displays and/
or stores the results in the memory, and highlights the
out-of-tolerance points.
As-found and As-left functions allow recording and
documenting results for quality control.
Download tasks and upload the results.
Snapshots allow you to capture and save data.

ISO 17025 accredited calibration with data

 

Built-in temperature readout
CVD coefficients of a calibrated PRT can be input into
the calibrator for accurate temperature measurement.

Multi lingual interface
English, German, French, Italian, Spanish,
Portuguese, Simplified Chinese
(Traditional Chinese, Japanese and Russian are
available per request)

Build-in unit conversion tool
Build-in converters for pressure units, temperature
units, temperature vs. resistance (RTDs), and
temperature vs millivolt (thermocouples)

Warranty: 3 years

 

HART Communication capability (223A)
Support HART®
 instrumentation

Display
3.5 inch TFT color screen

Misuse protection
Up to 30V voltage on any two sockets and up to
1A current on current sockets will not damage the
calibrator. The calibrator will return to normal condition
as soon as the voltage or current is removed.

Rechargeable battery
Rechargeable Li-ion battery for 15 hours uninterrupted
use.
Battery life will be reduced when 24 V is applied.
The rechargeable battery is replaceable.

 

Measurement Accuracy
  Range Resolution Accuracy
Voltage DC ±75.0000 mV 0.1μV 0.01%RD + 3.75 μV
±30.0000 V 0.1 mV 0.01%RD + 1.5 mV
Current DC ± 30.0000 mA 0.1μA 0.01%RD + 1.5 μA
Resistance Two-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω
Three-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω
Four-wire 0 to 400.000 Ω 1mΩ 0.01%RD + 0.02 Ω
Two-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω
Three-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω
Four-wire 0 to 4000.00 Ω 10mΩ 0.01%RD + 0.2 Ω
Frequency 1 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz
Pulse 0 to 999999 1 N/A
Limit Switch For the contact with potential, the voltage within the range 3V to 24V.

 

Source Accuracy
Voltage DC -10.000 to 75.000mV 1μV 0.02%RD + 4.25 μV
  0 to 12.0000 V 0.1mV 0.02%RD + 0.6 mV
Current DC 0 to 22.000 mA 1μA 0.02%RD + 1.1 μA
Resistance 1 to 400.00 Ω 10mΩ 0.02%RD + 0.02 Ω
  1 to 4000.0 Ω 100mΩ 0.03%RD + 0.4 Ω
Frequency 0 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz
Pulse 0 to 999999 1 N/A
DC24V N/A N/A 0.5V

 

Thermocouple Measurement and Source Accuracy
Measure and Simulate Standard Temperature Range (oC) Accuracy (oC)
Measure Source
S IEC 584 -50 to 1768 -50 to400 1 1.1
400 to 1000 0.6 0.6
1000 to1768 0.7 0.8
R IEC 584 -50 to 1768 -50 to 200 1.4 1.4
200 to 500 0.6 0.6
500 to 1768 0.6 0.7
B IEC 584 0 to 1820 50 to 450 3.8 3.8
450 to 800 0.9 0.9
800 to 1820 0.6 0.7
K IEC 584 -270 to 1372 -250 to -200 1 1.1
-200 to -100 0.4 0.5
-100 to 600 0.3 0.3
600 to 1372 0.4 0.5
N IEC 584 -270 to 1300 -250 to -200 1.5 1.6
-200 to -100 0.5 0.6
-100 to 1300 0.4 0.5
E IEC 584 -270 to 1000 -250 to -200 0.6 0.7
-200 to -100 0.3 0.3
-100 to 0 0.2 0.2
0 to 700 0.2 0.3
700 to 1000 0.2 0.4
J IEC 584 -270 to 1200 -210 to -100 0.3 0.3
-100 to 1200 0.3 0.4
T IEC 584 -270 to 400 -250 to -200 0.8 0.9
-200 to 0 0.4 0.4
0 to 400 0.2 0.2
C ASTM E988 0 to 2315 0 to 1000 0.5 0.5
1000 to 1800 0.7 0.9
1800 to 2315 1 1.4
D ASTM E988 0 to 2320 0 to 100 0.5 0.5
100 to 1100 0.4 0.5
1100 to 2000 0.6 0.9
2000 to 2320 0.9 1.3
G ASTM E1751 0 to 2315 0 to 200 2.4 2.4
200 to 400 0.5 0.5
400 to 1400 0.4 0.5
1400 to 2315 0.7 1
L DIN43710 -200 to 900 -200 to -100 0.2 0.3
-100 to 400 0.2 0.2
400 to 900 0.2 0.3
U DIN43710 -200 to 600 -200 to 0 0.4 0.4
0 to 600 0.2 0.3
*Accuracy with external cold junction; for internal cold junction add 0.1°C (k=2)

 

Measurement Accuracy
Measure and Simulate Standard Temperature Range (°C) Accuracy (°C)
Measure (2W/3W) Measure (4W) Source
Pt10(385) IEC 751 -200 to 850 -100 to 200 0.65 0.6 0.65
200 to 600 0.82 0.72 0.82
600 to 850 0.96 0.82 0.96
Pt100(385) IEC 751 -200 to 850 -100 to 200 0.15 0.1 0.15
200 to 600 0.26 0.16 0.26
600 to 850 0.34 0.2 0.34
Pt100(3916) JIS 1604 -200 to 850 -100 to 200 0.15 0.1 0.15
200 to 600 0.26 0.16 0.26
600 to 850 0.33 0.2 0.33
Pt100(3926) Minco Application Aid #18 -200 to 850 -100 to 200 0.15 0.1 0.15
200 to 600 0.26 0.16 0.26
600 to 850 0.33 0.2 0.33
Pt500(385) IEC 751 -200 to 850 -100 to 200 0.2 0.16 0.36
200 to 600 0.32 0.22 0.54
600 to 850 0.4 0.27 0.67
Pt1000(385) IEC 751 -200 to 850 -100 to 200 0.1 0.05 0.25
200 to 600 0.2 0.1 0.42
600 to 850 0.27 0.14 0.54
Cu10(427) Minco Application Aid #18 -100 to 260 -100 to 260 0.61 0.56 0.61
Cu50(428) GOST 6651-94 -50 to 150 -50 to 150 0.17 0.13 0.17
Cu100(428) GOST 6651-94 -50 to 150 -50 to 150 0.12 0.09 0.12
Ni120(672) Edison curve #7 -100 to 260 -100 to 260 0.07 0.05 0.07
Ni100(618) DIN 43760 -100 to 260 -100 to 260 0.08 0.06 0.08

 

General Specifications
Operating Temperature -10°C to 50°C
Storage Temperature -20°C to 60°C
Humidity <90%, non-condensing
European Compliance CE Mark
Protection Level IP30
Display 3.5 inch TFT color screen
Electrical Connection Ø4mm sockets and flat mini-jack thermocouple socket
RS232 Interface Standard RS232-DB9 socket
Size 3.9″ x 7.6″ x 2.0″ (100mm x 192mm x 52mm)
Weight 1.6 lb (0.7 kg)
Power Supply Polymer Li-ion rechargeable battery,or 10V DC adaptor
Battery Rechargeable Li-ion battery (included)
Battery Life 15 hours uninterrupted use
Battery life will be reduced when 24V is applied
Battery Charge 110V/220V external power adapter (included)








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Additel 221A Multifunction Temperature Calibrator

    No longer available. This product is no longer offered.
    Recommended alternative: Additel ADT209 / ADT210 Series Loop Calibrator
    • Sourcing, simulating and measuring, temperature and electrical signals
    • Smartphone-like menu and interface make the operation simpler and easier
    • The internal cold junction compensation sensor can be re-calibrated  at ice point by users
    • Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)
    • ISO 17025-accredited calibration w/data included
    Datasheet

    A highly integrated Multifunction Temperature Calibrator featuring several patented technologies, the 221A is an ultra-compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring temperature, and electrical signals. Its smartphone-like menu and interface make the operation simpler and easier. The 221A is ideal for calibrating, maintaining, and troubleshooting process instrumentations. Automation and documentation capabilities make the 221A a turnkey solution.

    Sourcing, simulating and measuring temperature and electrical
    signals
    Sources and measures mV, mA, ohms, RTDs,
    thermocouples, frequency, and pulses
    Simulates and measures 13 thermocouples and 11
    RTDs to calibrate transmitters
    Measures and sources pressure using Additel 160A
    series Intelligent Digital Pressure Modules from -15 psi
    to 10,000 psi (-1 bar to 700 bar)
    24V loop power supply
    Simultaneous dual reading capability
    Automatic switch test
    Supports square root transmitter
    Pulse frequency output for the calibration of flow totalizer

    Easy to use
    Smartphone-like menu and interface make the operation
    simpler and easier
    Ultra-compact, size 3.9″ x 7.6″ x 2.0″ (100mm x 192mm
    x 52mm), and weight 1.6 lb (0.7 kg)
    One handed operation

     

    Calibrated cold junction compensation (Patented)
    Cold junction equalizing block in the calibrator
    A calibrated PRT element with flexible leads is
    installed
    in the equalizing block for thermocouple cold junction
    compensation
    This PRT element can be pulled out from the calibrator
    and re-calibrated and corrected at the ice point

    Documenting and automated procedure capability
    Manage the information of the device under test.
    Set up automated calibration procedures, and 223A
    performs the test, calculates the errors, displays and/
    or stores the results in the memory, and highlights the
    out-of-tolerance points.
    As-found and As-left functions allow recording and
    documenting results for quality control.
    Download tasks and upload the results.
    Snapshots allow you to capture and save data.

    ISO 17025 accredited calibration with data

     

    Built-in temperature readout
    CVD coefficients of a calibrated PRT can be input into
    the calibrator for accurate temperature measurement.

    Multi lingual interface
    English, German, French, Italian, Spanish,
    Portuguese, Simplified Chinese
    (Traditional Chinese, Japanese and Russian are
    available per request)

    Build-in unit conversion tool
    Build-in converters for pressure units, temperature
    units, temperature vs. resistance (RTDs), and
    temperature vs millivolt (thermocouples)

    Warranty: 3 years

     

    HART Communication capability (223A)
    Support HART®
     instrumentation

    Display
    3.5 inch TFT color screen

    Misuse protection
    Up to 30V voltage on any two sockets and up to
    1A current on current sockets will not damage the
    calibrator. The calibrator will return to normal condition
    as soon as the voltage or current is removed.

    Rechargeable battery
    Rechargeable Li-ion battery for 15 hours uninterrupted
    use.
    Battery life will be reduced when 24 V is applied.
    The rechargeable battery is replaceable.

     

    Measurement Accuracy
      Range Resolution Accuracy
    Voltage DC ±75.0000 mV 0.1μV 0.01%RD + 3.75 μV
    ±30.0000 V 0.1 mV 0.01%RD + 1.5 mV
    Current DC ± 30.0000 mA 0.1μA 0.01%RD + 1.5 μA
    Resistance Two-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω
    Three-wire 0 to 400.000 Ω 1mΩ 0.02%RD + 0.02 Ω
    Four-wire 0 to 400.000 Ω 1mΩ 0.01%RD + 0.02 Ω
    Two-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω
    Three-wire 0 to 4000.00 Ω 10mΩ 0.02%RD + 0.2 Ω
    Four-wire 0 to 4000.00 Ω 10mΩ 0.01%RD + 0.2 Ω
    Frequency 1 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz
    Pulse 0 to 999999 1 N/A
    Limit Switch For the contact with potential, the voltage within the range 3V to 24V.

     

    Source Accuracy
    Voltage DC -10.000 to 75.000mV 1μV 0.02%RD + 4.25 μV
      0 to 12.0000 V 0.1mV 0.02%RD + 0.6 mV
    Current DC 0 to 22.000 mA 1μA 0.02%RD + 1.1 μA
    Resistance 1 to 400.00 Ω 10mΩ 0.02%RD + 0.02 Ω
      1 to 4000.0 Ω 100mΩ 0.03%RD + 0.4 Ω
    Frequency 0 to 50000.0 Hz 0.1Hz 0.005%RD + 1 Hz
    Pulse 0 to 999999 1 N/A
    DC24V N/A N/A 0.5V

     

    Thermocouple Measurement and Source Accuracy
    Measure and Simulate Standard Temperature Range (oC) Accuracy (oC)
    Measure Source
    S IEC 584 -50 to 1768 -50 to400 1 1.1
    400 to 1000 0.6 0.6
    1000 to1768 0.7 0.8
    R IEC 584 -50 to 1768 -50 to 200 1.4 1.4
    200 to 500 0.6 0.6
    500 to 1768 0.6 0.7
    B IEC 584 0 to 1820 50 to 450 3.8 3.8
    450 to 800 0.9 0.9
    800 to 1820 0.6 0.7
    K IEC 584 -270 to 1372 -250 to -200 1 1.1
    -200 to -100 0.4 0.5
    -100 to 600 0.3 0.3
    600 to 1372 0.4 0.5
    N IEC 584 -270 to 1300 -250 to -200 1.5 1.6
    -200 to -100 0.5 0.6
    -100 to 1300 0.4 0.5
    E IEC 584 -270 to 1000 -250 to -200 0.6 0.7
    -200 to -100 0.3 0.3
    -100 to 0 0.2 0.2
    0 to 700 0.2 0.3
    700 to 1000 0.2 0.4
    J IEC 584 -270 to 1200 -210 to -100 0.3 0.3
    -100 to 1200 0.3 0.4
    T IEC 584 -270 to 400 -250 to -200 0.8 0.9
    -200 to 0 0.4 0.4
    0 to 400 0.2 0.2
    C ASTM E988 0 to 2315 0 to 1000 0.5 0.5
    1000 to 1800 0.7 0.9
    1800 to 2315 1 1.4
    D ASTM E988 0 to 2320 0 to 100 0.5 0.5
    100 to 1100 0.4 0.5
    1100 to 2000 0.6 0.9
    2000 to 2320 0.9 1.3
    G ASTM E1751 0 to 2315 0 to 200 2.4 2.4
    200 to 400 0.5 0.5
    400 to 1400 0.4 0.5
    1400 to 2315 0.7 1
    L DIN43710 -200 to 900 -200 to -100 0.2 0.3
    -100 to 400 0.2 0.2
    400 to 900 0.2 0.3
    U DIN43710 -200 to 600 -200 to 0 0.4 0.4
    0 to 600 0.2 0.3
    *Accuracy with external cold junction; for internal cold junction add 0.1°C (k=2)

     

    Measurement Accuracy
    Measure and Simulate Standard Temperature Range (°C) Accuracy (°C)
    Measure (2W/3W) Measure (4W) Source
    Pt10(385) IEC 751 -200 to 850 -100 to 200 0.65 0.6 0.65
    200 to 600 0.82 0.72 0.82
    600 to 850 0.96 0.82 0.96
    Pt100(385) IEC 751 -200 to 850 -100 to 200 0.15 0.1 0.15
    200 to 600 0.26 0.16 0.26
    600 to 850 0.34 0.2 0.34
    Pt100(3916) JIS 1604 -200 to 850 -100 to 200 0.15 0.1 0.15
    200 to 600 0.26 0.16 0.26
    600 to 850 0.33 0.2 0.33
    Pt100(3926) Minco Application Aid #18 -200 to 850 -100 to 200 0.15 0.1 0.15
    200 to 600 0.26 0.16 0.26
    600 to 850 0.33 0.2 0.33
    Pt500(385) IEC 751 -200 to 850 -100 to 200 0.2 0.16 0.36
    200 to 600 0.32 0.22 0.54
    600 to 850 0.4 0.27 0.67
    Pt1000(385) IEC 751 -200 to 850 -100 to 200 0.1 0.05 0.25
    200 to 600 0.2 0.1 0.42
    600 to 850 0.27 0.14 0.54
    Cu10(427) Minco Application Aid #18 -100 to 260 -100 to 260 0.61 0.56 0.61
    Cu50(428) GOST 6651-94 -50 to 150 -50 to 150 0.17 0.13 0.17
    Cu100(428) GOST 6651-94 -50 to 150 -50 to 150 0.12 0.09 0.12
    Ni120(672) Edison curve #7 -100 to 260 -100 to 260 0.07 0.05 0.07
    Ni100(618) DIN 43760 -100 to 260 -100 to 260 0.08 0.06 0.08

     

    General Specifications
    Operating Temperature -10°C to 50°C
    Storage Temperature -20°C to 60°C
    Humidity <90%, non-condensing
    European Compliance CE Mark
    Protection Level IP30
    Display 3.5 inch TFT color screen
    Electrical Connection Ø4mm sockets and flat mini-jack thermocouple socket
    RS232 Interface Standard RS232-DB9 socket
    Size 3.9″ x 7.6″ x 2.0″ (100mm x 192mm x 52mm)
    Weight 1.6 lb (0.7 kg)
    Power Supply Polymer Li-ion rechargeable battery,or 10V DC adaptor
    Battery Rechargeable Li-ion battery (included)
    Battery Life 15 hours uninterrupted use
    Battery life will be reduced when 24V is applied
    Battery Charge 110V/220V external power adapter (included)








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.