WIKA Model GLTC10 combination valve Gas Leak Tight Connection 3-way combination valve


  • Optional customer adaptions
  • Designed for repeated opening and closing
  • Helium leak tested to a level of 1 · 10-8 mbar · l / sec to ensure a leak-tight system
Datasheet

Applications

  • 3-way self-sealing valve allowing for isolation of gas density monitor

 

Description

Keeping SF6 gas inside circuit-breaker tanks during the filling process is nearly impossible without using a self-sealing coupling. This special 3-way valve features a DN 20 tank fillport and a special regulation valve to allow leak-free checking of the gas density monitor, and a self-sealing valve for the gas density monitor.

The valve is normally in the “open” position so that SF6 gas flows to the gas density monitor. However, it can be moved to the “close” position using a special key to turn the valve. The exact position of the valve can easily be seen because the red arrow of the screw points toward the visual band where “open” or “close” is indicated. Once the screw reaches the first part of the “close” band, it is 100 % closed. However, further tightening deeper into the “close” band is also possible.

The DN 20 valve and gas density monitor connection threads are greased with graphite in order to make it easier to attach or remove the GLTC20 protective cap.

Tank thread size
DN 20 (nominal size 20 mm)

Permissible temperature
Ambient: -40 °C … +60 °C

Permissible pressure
Max. 10 bar









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Model GLTC10 combination valve Gas Leak Tight Connection 3-way combination valve

    • Optional customer adaptions
    • Designed for repeated opening and closing
    • Helium leak tested to a level of 1 · 10-8 mbar · l / sec to ensure a leak-tight system
    Datasheet

    Applications

    • 3-way self-sealing valve allowing for isolation of gas density monitor

     

    Description

    Keeping SF6 gas inside circuit-breaker tanks during the filling process is nearly impossible without using a self-sealing coupling. This special 3-way valve features a DN 20 tank fillport and a special regulation valve to allow leak-free checking of the gas density monitor, and a self-sealing valve for the gas density monitor.

    The valve is normally in the “open” position so that SF6 gas flows to the gas density monitor. However, it can be moved to the “close” position using a special key to turn the valve. The exact position of the valve can easily be seen because the red arrow of the screw points toward the visual band where “open” or “close” is indicated. Once the screw reaches the first part of the “close” band, it is 100 % closed. However, further tightening deeper into the “close” band is also possible.

    The DN 20 valve and gas density monitor connection threads are greased with graphite in order to make it easier to attach or remove the GLTC20 protective cap.

    Tank thread size
    DN 20 (nominal size 20 mm)

    Permissible temperature
    Ambient: -40 °C … +60 °C

    Permissible pressure
    Max. 10 bar









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.