DCMV10 pressure switch, setting range 1…10 bar, switching differential 0.5…2.8 bar, max. permissible pressure 25 bar


  • Type: DCMV10
  • Setting range: 1…10 bar
  • Switching differential: 0.5…2.8 bar
  • Max. permissible pressure: 25 bar
  • Materials in contact with medium: sensor housing 1.4104 + pressure bellows 1.4571
  • Switching differential adjustable: Yes

Datasheet

The universal pressure switch DCMV10 is suitable for use in general mechanical engineering, the printing machine industry, as well as in pneumatics and hydraulics. This type covers a setting range of 1…10 bar and is designed for a maximum permissible pressure of 25 bar.

The switching differential can be adjusted externally for this type. The available range is 0.5…2.8 bar.

The DCM/DNM series is designed for overpressure monitoring in industrial applications. The devices have a robust design and can be adjusted externally using a screwdriver. Depending on the version, different materials are used for the pressure-wetted parts.

Technical data

  • Pressure connection: External thread G 1/2 (pressure gauge connection) according to DIN 16 288 and internal thread G 1/4 according to ISO 228 Part 1.
  • Switching device: Robust housing (200) made of seawater-resistant die-cast aluminium GD Al Si 12.
  • Protection class: IP54 in vertical position.
  • Pressure sensor materials: Type-dependent, see product summary in the datasheet.
  • Mounting position: Vertically upright and horizontal. DCM4016 and DCM4025 vertically upright.
  • Ambient temperature at switching device: -25…+70 °C; DCM4016, DCM4025 and DCM1000: -15…+60 °C.
  • Max. medium temperature: The maximum medium temperature at the pressure sensor must not exceed the permitted ambient temperature at the switching device. Short-term temperatures up to 85 °C are possible. Higher medium temperatures are possible if the limit values at the switching device are ensured by suitable measures, for example a siphon.
  • Mounting: Directly on the pressure line (pressure gauge connection) or on a flat surface with two 4 mm diameter screws.
  • Switching pressure: Adjustable externally with a screwdriver.
  • Switching differential: Not adjustable for DCM types. Adjustable externally for DCMV types. See product summary for values.
  • Contact arrangement: Single-pole changeover switch.
  • Switching capacity: See datasheet for the electrical switching capacity values.




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    DCMV10 pressure switch, setting range 1…10 bar, switching differential 0.5…2.8 bar, max. permissible pressure 25 bar

    • Type: DCMV10
    • Setting range: 1…10 bar
    • Switching differential: 0.5…2.8 bar
    • Max. permissible pressure: 25 bar
    • Materials in contact with medium: sensor housing 1.4104 + pressure bellows 1.4571
    • Switching differential adjustable: Yes

    Datasheet

    The universal pressure switch DCMV10 is suitable for use in general mechanical engineering, the printing machine industry, as well as in pneumatics and hydraulics. This type covers a setting range of 1…10 bar and is designed for a maximum permissible pressure of 25 bar.

    The switching differential can be adjusted externally for this type. The available range is 0.5…2.8 bar.

    The DCM/DNM series is designed for overpressure monitoring in industrial applications. The devices have a robust design and can be adjusted externally using a screwdriver. Depending on the version, different materials are used for the pressure-wetted parts.

    Technical data

    • Pressure connection: External thread G 1/2 (pressure gauge connection) according to DIN 16 288 and internal thread G 1/4 according to ISO 228 Part 1.
    • Switching device: Robust housing (200) made of seawater-resistant die-cast aluminium GD Al Si 12.
    • Protection class: IP54 in vertical position.
    • Pressure sensor materials: Type-dependent, see product summary in the datasheet.
    • Mounting position: Vertically upright and horizontal. DCM4016 and DCM4025 vertically upright.
    • Ambient temperature at switching device: -25…+70 °C; DCM4016, DCM4025 and DCM1000: -15…+60 °C.
    • Max. medium temperature: The maximum medium temperature at the pressure sensor must not exceed the permitted ambient temperature at the switching device. Short-term temperatures up to 85 °C are possible. Higher medium temperatures are possible if the limit values at the switching device are ensured by suitable measures, for example a siphon.
    • Mounting: Directly on the pressure line (pressure gauge connection) or on a flat surface with two 4 mm diameter screws.
    • Switching pressure: Adjustable externally with a screwdriver.
    • Switching differential: Not adjustable for DCM types. Adjustable externally for DCMV types. See product summary for values.
    • Contact arrangement: Single-pole changeover switch.
    • Switching capacity: See datasheet for the electrical switching capacity values.