PACE5000 E Modular High-Precision Pressure Controller (Single-channel pressure controller)

from 2,539.00 €
plus VAT

Options & pricing

with one control module: from 2.539,00 €

with two controle modules: from 1.801,00 €


  • Single-channel pressure controller housing
  • Compatible with any interchangeable PACE CM module
  • Ideal for end-of-line tests as well as laboratory and workshop environments due to compact design and high control stability
  • Highest precision: Measurement accuracy up to 0.001% of full scale (FS) for the most demanding calibration and testing applications.
  • Pressure range: 25 mbar – 210 bar
  • Industry-leading controller performance (speed, accuracy, and stability) for both small and large volumes
  • Highest measurement accuracy with minimal measurement uncertainty (12-month specification)
  • Completely redesigned user interface with larger display area
  • Simple and intuitive menu structure with context-sensitive help
  • Test bench connectivity with HDMI monitor output, mouse and keyboard
  • “Drop-in” replacement for PACE5000 with backward compatibility of control modules
  • Improved diagnostic tools
  • Windows USB driver with automatic installation
  • Standards-compliant communication: GPIB IEEE-488, RS232, SCPI-99, USBTMC, LXI 1.6 standard (VXI-11 & HiSLIP), NI IVI-C and LabVIEW-certified instrument drivers
Datasheet
User Manual
Videos

Applications and Industries

Laboratory, production, R&D, and calibration applications in the following areas:

  • Aerospace, defense
  • Energy
  • Healthcare and pharmaceutical industry
  • Electronics and semiconductors
  • Transportation
  • Metrology and calibration
  • Environment
  • General industry

Device Concepts

PACE5000E Housing

  • Single-channel pressure controller housing
  • Compatible with any interchangeable PACE CM module
  • Ideal for end-of-line tests as well as laboratory and workshop environments due to compact design and high control stability

PACE6000E Housing

  • Dual-channel pressure controller housing
  • Can operate with two CM modules in single, auto-ranging, or dual mode
  • No restriction on pressure ratio between channels
  • High flexibility – suitable for both industrial and laboratory use

PACE Control Modules

  • Interchangeable control modules (CM) include all valves, sensors, and manifolds
  • Easy to replace without removing the entire housing
  • Optimally adapted for specific pressure ranges
  • Only the CM module needs maintenance or calibration
  • Housing can remain permanently installed

Stability and Accuracy

  • Response time in fast mode: approx. 1.5 seconds*
  • Response time in high accuracy mode: ≤ 3 seconds**
  • PACE controllers stabilize faster than other devices at ≤ 0.001% FS stability

*Optimal conditions, external load < 100 ml
**May take up to 2 seconds longer with larger loads

Long-Term Stability

Druck Ltd. designs and manufactures all sensors in-house, ensuring precise compliance with specifications. This eliminates the need for frequent recalibrations during the calibration cycle.

User Interface

The intuitive touchscreen interface enables easy operation with:

  • Display of measured pressure and pressure range
  • Simple switching between ranges and units
  • Direct setpoint input
  • Single-channel or dual-channel operation (PACE6000 only)

Integration & Calibration Systems

LXI™ LAN Extension

  • Seamless integration into existing networks
  • Troubleshooting, remote maintenance, and updates via LAN

4Sight2 Calibration Software

  • Comprehensive overview of test equipment and calibration status
  • Automated calibration or test routines possible
  • Uncertainty calculation, certificate issuance, paperless process
  • Drift analysis using trend data

4Sight2 enables for example:

  • Calibration of pressure sensors, transmitters, switches
  • End-of-line testing
  • Calibration of third-party equipment
  • Standardization of calibration processes across companies

Optional Test Methods

Leak Test

The leak test determines the leakage of a system based on defined pressure steps. After stabilization, pressure difference and leak rate are displayed.

Burst Pressure Test

The burst pressure test increases the pressure in a device until failure. The exact burst pressure point is recorded.

PACE5000 E Device Specifications

Pressure Measurement
CM0/CM1/CM2 pressure ranges: 25, 70, 200, 350, and 700 mbar gauge, 1.2, 3.5, 7, 10, 20, 35, 70, 100, 135, 172, 210 bar gauge
0.35, 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 1000, 1500, 2000, 2500, 3000 psi gauge
2.5, 7, 20, 35, 70, 100, 200, 350, 700 kPa gauge
1, 2, 3, 5, 7, 10, 13.5, 17, 21 MPa gauge
Note: All ranges also available with negative calibration. For absolute pressure, any range from 1 bar upwards can be selected (with barometric option).
CM3 pressure ranges: 1.25, 7, 10, 20, 35, 70, 100, 135, 172, 210 bar pseudo gauge
2.35, 8.1, 21, 136, 173, 211 bar absolute
15, 36, 101, 148, 280, 507, 1015, 1450, 1958, 2494, 3046 psi pseudo gauge
28, 44, 73, 160, 308, 522, 1030, 1485, 1973, 2509, 3060 psi absolute
0.1, 0.25, 0.7, 1.2, 3.5, 7, 10, 13.5, 17, 21 MPa pseudo gauge
0.2, 0.35, 0.8, 1.1, 2.1, 3.6, 7.1, 10.1, 13.6, 17.3, 21.1 MPa absolute
Overpressure indication: 10% above full scale
Media: Dry, oil-free, non-flammable gases maintained at 10% above the required outlet pressure. Nitrogen recommended.
Display
PACE5000E: LCD color display with touchscreen, 216 mm × 54 mm (8.5″ × 2.1″)
Communication update rate: 20 times per second
Display update rate: 2 times per second
Display range: ±99999999
Pressure units: mbar, bar, Pa, kPa, MPa, psi, atm, torr, mmHg @0°C, inHg @0°C, mmH₂O @4°C, cmH₂O, kg/m² etc.
Performance
PACE CM0 standard accuracy: 0.02% of reading + 0.025% FS
PACE CM0 control stability: 0.005% FS
PACE CM1 high precision: 0.01% of reading + 0.01% FS
PACE CM1 control stability: 0.003% FS
PACE CM2 premium accuracy: 0.005% of reading + 0.005% FS
PACE CM2 control stability: 0.001% FS
PACE CM3 reference accuracy: 0.001% FS for 2, 3.5 bar
0.0015% FS for 8–21 bar
PACE CM3 control stability: 0.001% of absolute range FS
PACE CM3 accuracy: 2, 3.5 bar: 0.0004% of reading + 0.0027% FS
8–11 bar: 0.0025% of reading + 0.0026% FS
136 bar: 0.0025% of reading + 0.0023% FS
173 bar: 0.0026% of reading + 0.0022% FS
211 bar: 0.0027% of reading + 0.0022% FS
Long-term stability: CM0–CM2: 0.01% of reading per year; 0.025% for 1 bar; 0.03% for 25–700 mbar
CM3: 0.0025% FS/year (2–3.5 bar), 0.001% FS in 28 days (8–21 bar)
Negative gauge accuracy: Error equals the error for the equivalent positive pressure
Pseudo accuracy: Pseudo absolute = gauge mode accuracy + barometric accuracy
PACE CM-B barometric accuracy: 0.10 mbar or 0.0015 psi
PACE CM1-B: 0.05 mbar or 0.00073 psi
PACE CM2-B: 0.025 mbar or 0.00036 psi
PACE CM3-B: 0.02 mbar or 0.00029 psi
PACE CM3-B barometric accuracy (2 sigma): 0.06 mbar
Gas consumption: Only during measurement; none in standby mode
Electrical
Power supply: 100–120/200–240 V AC, 50/60 Hz
Communication
Interfaces: USB-A, USB-C, USB TMC, Ethernet (LXI), RS232 (optional), GPIB IEEE-488 (optional), SCP199 compatible (DPI520, DPI500, DPI510, DPI515)
Environment
Operating temperature: 0 °C to 55 °C
Calibration temperature: 15 °C to 45 °C
Storage temperature: -20 °C to 70 °C
Humidity: 5% to 95% RH, non-condensing
Protection rating: IP20 (EN60529), indoor use only
Vibration: Def Stan 66-31, MIL-PRF-28800
Shock: Complies with EN61010-1
Standards: UL 61010-1, EN61326-1, PED, RoHS, WEEE, CE
Physical
Chassis weight: PACE5000E: 5.6 kg
CM module weight: 5 kg
Pressure connection: G 1/8″ female (1/8″ NPT for North America)
PACE 5000E dimensions: 440 mm × 88 mm (2U) × 320 mm

Note: To meet the annual accuracy specification of CM3 modules, it is recommended to perform a zero correction every 28 days using a barometric reference. Long-term stability depends on the specifications of the barometric reference used. The values stated apply to CM3-B.



Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    PACE5000 E Modular High-Precision Pressure Controller (Single-channel pressure controller)

    from 2,539.00 €
    plus VAT

    Options & pricing

    with one control module: from 2.539,00 €

    with two controle modules: from 1.801,00 €

    • Single-channel pressure controller housing
    • Compatible with any interchangeable PACE CM module
    • Ideal for end-of-line tests as well as laboratory and workshop environments due to compact design and high control stability
    • Highest precision: Measurement accuracy up to 0.001% of full scale (FS) for the most demanding calibration and testing applications.
    • Pressure range: 25 mbar – 210 bar
    • Industry-leading controller performance (speed, accuracy, and stability) for both small and large volumes
    • Highest measurement accuracy with minimal measurement uncertainty (12-month specification)
    • Completely redesigned user interface with larger display area
    • Simple and intuitive menu structure with context-sensitive help
    • Test bench connectivity with HDMI monitor output, mouse and keyboard
    • “Drop-in” replacement for PACE5000 with backward compatibility of control modules
    • Improved diagnostic tools
    • Windows USB driver with automatic installation
    • Standards-compliant communication: GPIB IEEE-488, RS232, SCPI-99, USBTMC, LXI 1.6 standard (VXI-11 & HiSLIP), NI IVI-C and LabVIEW-certified instrument drivers
    Datasheet
    User Manual
    Videos

    Applications and Industries

    Laboratory, production, R&D, and calibration applications in the following areas:

    • Aerospace, defense
    • Energy
    • Healthcare and pharmaceutical industry
    • Electronics and semiconductors
    • Transportation
    • Metrology and calibration
    • Environment
    • General industry

    Device Concepts

    PACE5000E Housing

    • Single-channel pressure controller housing
    • Compatible with any interchangeable PACE CM module
    • Ideal for end-of-line tests as well as laboratory and workshop environments due to compact design and high control stability

    PACE6000E Housing

    • Dual-channel pressure controller housing
    • Can operate with two CM modules in single, auto-ranging, or dual mode
    • No restriction on pressure ratio between channels
    • High flexibility – suitable for both industrial and laboratory use

    PACE Control Modules

    • Interchangeable control modules (CM) include all valves, sensors, and manifolds
    • Easy to replace without removing the entire housing
    • Optimally adapted for specific pressure ranges
    • Only the CM module needs maintenance or calibration
    • Housing can remain permanently installed

    Stability and Accuracy

    • Response time in fast mode: approx. 1.5 seconds*
    • Response time in high accuracy mode: ≤ 3 seconds**
    • PACE controllers stabilize faster than other devices at ≤ 0.001% FS stability

    *Optimal conditions, external load < 100 ml
    **May take up to 2 seconds longer with larger loads

    Long-Term Stability

    Druck Ltd. designs and manufactures all sensors in-house, ensuring precise compliance with specifications. This eliminates the need for frequent recalibrations during the calibration cycle.

    User Interface

    The intuitive touchscreen interface enables easy operation with:

    • Display of measured pressure and pressure range
    • Simple switching between ranges and units
    • Direct setpoint input
    • Single-channel or dual-channel operation (PACE6000 only)

    Integration & Calibration Systems

    LXI™ LAN Extension

    • Seamless integration into existing networks
    • Troubleshooting, remote maintenance, and updates via LAN

    4Sight2 Calibration Software

    • Comprehensive overview of test equipment and calibration status
    • Automated calibration or test routines possible
    • Uncertainty calculation, certificate issuance, paperless process
    • Drift analysis using trend data

    4Sight2 enables for example:

    • Calibration of pressure sensors, transmitters, switches
    • End-of-line testing
    • Calibration of third-party equipment
    • Standardization of calibration processes across companies

    Optional Test Methods

    Leak Test

    The leak test determines the leakage of a system based on defined pressure steps. After stabilization, pressure difference and leak rate are displayed.

    Burst Pressure Test

    The burst pressure test increases the pressure in a device until failure. The exact burst pressure point is recorded.

    PACE5000 E Device Specifications

    Pressure Measurement
    CM0/CM1/CM2 pressure ranges: 25, 70, 200, 350, and 700 mbar gauge, 1.2, 3.5, 7, 10, 20, 35, 70, 100, 135, 172, 210 bar gauge
    0.35, 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 1000, 1500, 2000, 2500, 3000 psi gauge
    2.5, 7, 20, 35, 70, 100, 200, 350, 700 kPa gauge
    1, 2, 3, 5, 7, 10, 13.5, 17, 21 MPa gauge
    Note: All ranges also available with negative calibration. For absolute pressure, any range from 1 bar upwards can be selected (with barometric option).
    CM3 pressure ranges: 1.25, 7, 10, 20, 35, 70, 100, 135, 172, 210 bar pseudo gauge
    2.35, 8.1, 21, 136, 173, 211 bar absolute
    15, 36, 101, 148, 280, 507, 1015, 1450, 1958, 2494, 3046 psi pseudo gauge
    28, 44, 73, 160, 308, 522, 1030, 1485, 1973, 2509, 3060 psi absolute
    0.1, 0.25, 0.7, 1.2, 3.5, 7, 10, 13.5, 17, 21 MPa pseudo gauge
    0.2, 0.35, 0.8, 1.1, 2.1, 3.6, 7.1, 10.1, 13.6, 17.3, 21.1 MPa absolute
    Overpressure indication: 10% above full scale
    Media: Dry, oil-free, non-flammable gases maintained at 10% above the required outlet pressure. Nitrogen recommended.
    Display
    PACE5000E: LCD color display with touchscreen, 216 mm × 54 mm (8.5″ × 2.1″)
    Communication update rate: 20 times per second
    Display update rate: 2 times per second
    Display range: ±99999999
    Pressure units: mbar, bar, Pa, kPa, MPa, psi, atm, torr, mmHg @0°C, inHg @0°C, mmH₂O @4°C, cmH₂O, kg/m² etc.
    Performance
    PACE CM0 standard accuracy: 0.02% of reading + 0.025% FS
    PACE CM0 control stability: 0.005% FS
    PACE CM1 high precision: 0.01% of reading + 0.01% FS
    PACE CM1 control stability: 0.003% FS
    PACE CM2 premium accuracy: 0.005% of reading + 0.005% FS
    PACE CM2 control stability: 0.001% FS
    PACE CM3 reference accuracy: 0.001% FS for 2, 3.5 bar
    0.0015% FS for 8–21 bar
    PACE CM3 control stability: 0.001% of absolute range FS
    PACE CM3 accuracy: 2, 3.5 bar: 0.0004% of reading + 0.0027% FS
    8–11 bar: 0.0025% of reading + 0.0026% FS
    136 bar: 0.0025% of reading + 0.0023% FS
    173 bar: 0.0026% of reading + 0.0022% FS
    211 bar: 0.0027% of reading + 0.0022% FS
    Long-term stability: CM0–CM2: 0.01% of reading per year; 0.025% for 1 bar; 0.03% for 25–700 mbar
    CM3: 0.0025% FS/year (2–3.5 bar), 0.001% FS in 28 days (8–21 bar)
    Negative gauge accuracy: Error equals the error for the equivalent positive pressure
    Pseudo accuracy: Pseudo absolute = gauge mode accuracy + barometric accuracy
    PACE CM-B barometric accuracy: 0.10 mbar or 0.0015 psi
    PACE CM1-B: 0.05 mbar or 0.00073 psi
    PACE CM2-B: 0.025 mbar or 0.00036 psi
    PACE CM3-B: 0.02 mbar or 0.00029 psi
    PACE CM3-B barometric accuracy (2 sigma): 0.06 mbar
    Gas consumption: Only during measurement; none in standby mode
    Electrical
    Power supply: 100–120/200–240 V AC, 50/60 Hz
    Communication
    Interfaces: USB-A, USB-C, USB TMC, Ethernet (LXI), RS232 (optional), GPIB IEEE-488 (optional), SCP199 compatible (DPI520, DPI500, DPI510, DPI515)
    Environment
    Operating temperature: 0 °C to 55 °C
    Calibration temperature: 15 °C to 45 °C
    Storage temperature: -20 °C to 70 °C
    Humidity: 5% to 95% RH, non-condensing
    Protection rating: IP20 (EN60529), indoor use only
    Vibration: Def Stan 66-31, MIL-PRF-28800
    Shock: Complies with EN61010-1
    Standards: UL 61010-1, EN61326-1, PED, RoHS, WEEE, CE
    Physical
    Chassis weight: PACE5000E: 5.6 kg
    CM module weight: 5 kg
    Pressure connection: G 1/8″ female (1/8″ NPT for North America)
    PACE 5000E dimensions: 440 mm × 88 mm (2U) × 320 mm

    Note: To meet the annual accuracy specification of CM3 modules, it is recommended to perform a zero correction every 28 days using a barometric reference. Long-term stability depends on the specifications of the barometric reference used. The values stated apply to CM3-B.