HT9023 TRMS AC/DC clamp-on power quality analyzer with wi-fi connection


HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems. It is also possible to carry out the phase sequence test with 1-terminal. The instrument also detects the events linked to motor starting currents (Dynamic INRUSH) and allows recording each measured electric parameter over time, with the possibility of transferring data via WiFi to Android/iOS devices through the HTAnalysis App (available from late 2020) or onto PC through the TOPVIEW software. The clamp is provided with a wide graphic dot-matrix screen (128x128pxl) with backlight, in order to allow reading data even in poorly lit environments, and it is provided with an auto power off function to preserve its internal battery.

Datasheet
User Manual
Functions
TRMS
Current measuring range 1000A
AC/DC current AC + DC
AC/DC voltage 1000VAC/1500VDC
Frequency
Resistance and continuity test with buzzer
Phase sequence and phase concordance
AC/DC voltage, current measurement/recording
Measurement/recording of Active, Reactive, Apparent AC/DC Energy
Measurement/recording of Cosphi, Power Factor
Measurement/recording of Active, Reactive, Apparent AC/DC Energy
Measurement/recording of V-I harmonics up to the 25th with THD%
Inrush current measurement (INRUSH) Dynamic INRUSH
Maximum diameter for clamp 45mm
Measuring counts 9999
Backlight
Autorange
Auto power off
Detection of AC voltage without contact
Data HOLD function
MIN/MAX function
PEAK function
Relative measurement
Datalogger and Graph
Memory for data saving
PC / Smartphone or Tablet interface WiFi
AC/DC voltage in single-phase/three-phase systems Single phase
AC/DC current in single-phase/three-phase systems Single phase
Electric motor starting current (INRUSH)
Neutral-Ground Voltage
Neutral current
Max number of simultaneously selectable parameters 60
Recording with selectable integration period 1s-15min
Indicative memory duration (in days @ PI= 30sec @ max number of parameters) 63 hours
Indication of recording duration
Internal memory storage 2MB
Saving instant sampled values
Summary table of main electric parameters
Voltage/current waveforms
Summary table of main electric parameters
Voltage/current waveforms
Tables or histograms of Harmonics and THD%
Voltage/current vector diagram
Power supply 2x 1.5V AAA
Measurement category CAT IV 600V CAT III 1000V
Weight in grams (batteries included) 420
Size (LxWx H) (mm) 252x88x44
Guidelines
  •  CE MARK
  •  IEC/EN61010-1








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    HT9023 TRMS AC/DC clamp-on power quality analyzer with wi-fi connection

    HT9023 has been designed to measure AC, DC AC+DC current up to 1000A in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp also measures DC voltage up to 1500V, AC, AC+DC voltage up to 1000V, Active, Reactive and Apparent Power, Power Factor, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems. It is also possible to carry out the phase sequence test with 1-terminal. The instrument also detects the events linked to motor starting currents (Dynamic INRUSH) and allows recording each measured electric parameter over time, with the possibility of transferring data via WiFi to Android/iOS devices through the HTAnalysis App (available from late 2020) or onto PC through the TOPVIEW software. The clamp is provided with a wide graphic dot-matrix screen (128x128pxl) with backlight, in order to allow reading data even in poorly lit environments, and it is provided with an auto power off function to preserve its internal battery.

    Datasheet
    User Manual
    Functions
    TRMS
    Current measuring range 1000A
    AC/DC current AC + DC
    AC/DC voltage 1000VAC/1500VDC
    Frequency
    Resistance and continuity test with buzzer
    Phase sequence and phase concordance
    AC/DC voltage, current measurement/recording
    Measurement/recording of Active, Reactive, Apparent AC/DC Energy
    Measurement/recording of Cosphi, Power Factor
    Measurement/recording of Active, Reactive, Apparent AC/DC Energy
    Measurement/recording of V-I harmonics up to the 25th with THD%
    Inrush current measurement (INRUSH) Dynamic INRUSH
    Maximum diameter for clamp 45mm
    Measuring counts 9999
    Backlight
    Autorange
    Auto power off
    Detection of AC voltage without contact
    Data HOLD function
    MIN/MAX function
    PEAK function
    Relative measurement
    Datalogger and Graph
    Memory for data saving
    PC / Smartphone or Tablet interface WiFi
    AC/DC voltage in single-phase/three-phase systems Single phase
    AC/DC current in single-phase/three-phase systems Single phase
    Electric motor starting current (INRUSH)
    Neutral-Ground Voltage
    Neutral current
    Max number of simultaneously selectable parameters 60
    Recording with selectable integration period 1s-15min
    Indicative memory duration (in days @ PI= 30sec @ max number of parameters) 63 hours
    Indication of recording duration
    Internal memory storage 2MB
    Saving instant sampled values
    Summary table of main electric parameters
    Voltage/current waveforms
    Summary table of main electric parameters
    Voltage/current waveforms
    Tables or histograms of Harmonics and THD%
    Voltage/current vector diagram
    Power supply 2x 1.5V AAA
    Measurement category CAT IV 600V CAT III 1000V
    Weight in grams (batteries included) 420
    Size (LxWx H) (mm) 252x88x44
    Guidelines
    •  CE MARK
    •  IEC/EN61010-1








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.