- Multi sensor system
- Simultaneous measuring of humidity, temperature and pressure
- Integrated 3-channel transmitter
- Graphical trend display of all parameters
- EU-RO Approval
Datasheet |
Datasheet |
User Manual |
- Multi sensor system
- Simultaneous measuring of humidity, temperature and pressure
- Integrated 3-channel transmitter
- Graphical trend display of all parameters
Datasheet |
User Manual |
- Easy & fast: connect, measure, read & record: Pressure, Temperature, Flow, RPM etc
- Flexible & multifunctional: measure most industrial sensor inputs - both analogue and frequency
- Digital & powerful: measure pressure peaks easily stored and recalled
- Precise and sustainable: Made to the highest standards to suit your environment
- Fast & Ready: Fast data transmission for accurate recording & sharing of key events
Datasheet
|
User Manual
|
- Flexible: 2 analog measuring inputs, and 1 frequency measuring input
- Easy to handle: huge keys, illuminated display
- Suited for field application: rugged aluminium housing
- Huge internal memory: For around 1 Million measure values
- Powerful battery supply: Measuring the whole day without charging
- Intuitive operations: with capacitive keypad
Datasheet
|
User Manual
|
- Instrument with 5 measuring channels, digital input and output and 10 special channels (for calculation and CAN) for mobile application
- Signal input for 0/4…20 mA, 0/2…10 V, 1…5 V, 0.5 … 4.5V, ±10V
- Signal input for frequency and impulses (counter) with direction detection, 0.25Hz … 20kHz
- AD-converter: 13 Bit
- Memory (microSD-card) for 100 measurements
- Max. 2 Mio. values per measurement
- USB device, RS232 interface, CAN interface
- Various options for channel extensions
Datasheet
|
User Manual
|
- Simple and intuitive menu navigation despite small dimensions.
- Backlit LCD display makes it easy to read measurement values.
- I ntegrated HYDROlink6 ADVACED software key (makes it possible to show measurement values on external monitors by using a PC or laptop)
- Excellent connectivity: TTL switching contact and trigger inputs and outputs
Datasheet
|
- 5” colored, daylight workable display
- graphical user interface
- 42 measuring channels
- 500 measurements up to 6 million values per measurement
- scanning rate up to 10 kHz
- 2 separate CAN
Datasheet
|
User Manual
|
- Table top instrument with 14 measuring channels, 4 digital input and output, 2 analog output and 6 (option 14) special channel (for calculation and CAN) for mobile application and test bench
- Signal input for 0/4 $ 20 mA,0 $ 10 V, ±10 V
- Signal input for for ±2ADC and±48VDC
- Signal input for frequency and impulses (counter) with direction detection, 0.05 Hz $ 5 kHz (20 kHz without direction)
- 2 High-speed analog inputs (10kHz)
- Memory (CF-card) for 200 measurements
- Up to 6 Mio. values per measurement
- USB, RS232 interface, CAN, LAN (option)
Without Display.
Datasheet
|
User Manual
|
- Up to 8 measurement channels
- Intrinsically safe
- Field Switchable Pressure Module
- Pressure Accuracy to 0.02% FS
- Temperature RTD Accuracy to 0.01% RDG + 0.005 % FS
- Data logging with Real-time Graphical Trending
- Supports Hydrostatic Testing
- Color Touchscreen Display
- Built-in Barometer
- Optional RTD Probes Available
- Bluetooth and USB Communication
- Communicates with Additel's Link Mobile App
- ISO 17025-accredited calibration w/data included
Datasheet |
User Manual |
- graphic LC display
- transducer supply 24 VDC
- communication interface RS-485 (Modbus RTU)
- front panel housing 96 x 96 mm
- 1, 4 oder 8 analog input ports
- input signal: 0/4 ... 20 mA, 0/1 ... 5 V, 0/2 ... 10 V
- communication interface USB 2.0
Datasheet |
User Manual |
- data acquisition of up to 60 channels
- 2 configurable sample rates (max. 10 Hz)
- extensive triggering functions
- internal memory 1.5 GB
- data transfer via USB memory stick or Ethernet
Datasheet |
User Manual |
- Data logger with 5 measuring channels, digital input and output and 10 special channels (for calculation and CAN) for mobile application
- Signal input for 0/4...20 mA, 0/2...10 V, 1...5 V, 0.5 ... 4.5V, ±10V
- Signal input for frequency and impulses (counter) with direction detection, 0.25Hz ... 20kHz
- AD-converter: 13 Bit
- Memory (microSD-card) for 100 measurements
- Max. 2 Mio. values per measurement
- USB device, LAN port, RS232 interface, CAN interface
- Various options for channel extensions
Datasheet |
- Measuring instrument for panel installation: with switchable input for analog and frequency sensors
- 9 High usability: comfortable reading of the large display
- 9 Large fl exibility: by optional outputs
- 9 Easy operation: with four keys and logical menu structure
Datasheet |
User Manual |
- Manual pressure generation of -0.85 … +25 bar [12.3 ... +360 psi]
- Accuracy: 0.025 % FS (incl. calibration certificate)
- Generation/measurement of 0 ... 24 mA and voltage supply DC 24 V
- Data logger with high measuring rate and large memory
- Intrinsically safe version
- Connections for 2 probes – position the data logger discreetly in the base of a display cabinet and monitor the micro-climate in the cabinet with the connectable probes
- Blends in perfectly with the surroundings thanks to an optional, customisable deco-cover
- Perfectly networked: data storage in the Testo Cloud, real-time alarm via email or SMS (optional in conjunction with an Advanced licence)
- Simple to install, integrate and operate
Datasheet |
- Ideal for monitoring indoor air quality (IAQ)
- Blends in perfectly with the surroundings thanks to an optional, customizable deco-cover
- Simple to install, integrate and operate – particularly user-friendly with air quality displayed in the form of a traffic light system
- Perfectly networked: data storage in the Testo Cloud, real-time alarm via email or SMS (optional in conjunction with an Advanced licence)
Datasheet |
- Data logger with integrated temperature and humidity sensor, small dimensions and discreet design
- Blends in perfectly with the surroundings thanks to an optional, customisable deco-cover
- Perfectly networked: data storage in the Testo Cloud, real-time alarm via email or SMS (optional in conjunction with an Advanced licence)
- Simple to install, integrate and operate
Datasheet |
- Ideal for your monitoring situation: integrated temperature and humidity sensor, as well as connection options for 2 additional probes
- Blends in perfectly with the surroundings thanks to an optional, customisable deco-cover
- Perfectly networked: data storage in the Testo Cloud, real-time alarm via email or SMS (optional in conjunction with an Advanced licence)
- Simple to install, integrate and operate
Datasheet |
- With integrated sensors for temperature and humidity, as well as lux and UV radiation
- Blends in perfectly with the surroundings thanks to an optional, customisable deco-cover
- Perfectly networked: data storage in the Testo Cloud, real-time alarm via email or (optionally in conjunction with an Advanced licence) SMS
- Simple to install, integrate and operate
Datasheet |
- Measurement data memory for up to 16,000 readings
- Temperature measuring range from -20 °C to +70 °C
- Automatic measuring data backup when the battery runs out or is changed
- Convenient Excel export functions
- Data analysis: three different software versions available, basic software free to download
- Displays violations of limit values
Datasheet
|
Saving energy, archiving, storing goods, creating a comfortable indoor climate – if you can’t analyze the temperature and humidity, you won’t get optimal results. The testo 175 H1 is designed to carry out reliable long-term measurements and log these crucial values for you.
- Transfer of measuring data via SD card
- Round-the-clock monitoring and logging of temperature, relative humidity and dew point
- Temperature measuring range from -20 °C to +70 °C
- Automatic measuring data backup when the battery runs out or is changed
- Professional software for programming the logger and data analysis
- Convenient Excel export functions
Datasheet |
- Easy programming and reporting without additional software (plug and play)
- Measurement data memory for up to 65,000 readings
- Easy-to-change battery
- Battery life up to 120 days
- Professional software for programming the logger and data analysis
- Convenient Excel export functions
Datasheet |
- Easy programming and reporting without additional software (plug and play)
- Measurement data memory for up to 64,000 readings
- Easy-to-change battery
- Battery life up to 500 days
- Professional software for programming the logger and data analysis
- Convenient Excel export functions
Datenblatt |
Multi-Parameter Data Loggers
Multi-parameter data loggers are devices capable of recording several measurement quantities simultaneously, such as temperature, humidity, pressure, voltage, current or digital signals. They offer a versatile solution for complex measurement tasks in laboratory environments, industrial processes and research applications. Typical features include multiple input channels, flexible sensor interfaces, extensive connectivity and long-term data recording capability.
FAQ
What is a multi-parameter data logger?
A multi-parameter data logger is an instrument that measures and records various physical or electrical quantities either simultaneously or sequentially. It can process both analog and digital signals.
Which measurement quantities can be recorded?
Common measured quantities include temperature, humidity, pressure, voltage, current, vibration, frequency or digital input/output signals. The available functions depend on the device configuration and connected sensors.
What advantages do multi-parameter loggers offer compared to single-parameter loggers?
They allow the simultaneous acquisition of multiple measurement variables with one device, reduce system complexity and provide synchronized datasets. This makes them ideal for system monitoring, diagnostics and research projects.
How flexible are the sensor inputs?
Many devices support modular input configurations and accept various signal types, such as mV/mA signals, thermocouples, RTDs, pulse inputs or digital channels. Connectivity options often include USB, Ethernet and wireless communication.
What should be considered when selecting a multi-parameter logger?
Important criteria include number of channels, measurement range per channel, sampling rate, synchronization accuracy, memory capacity, connectivity, isolation, environmental rating and available software tools.
How is data transferred and analyzed?
Logged data can be transmitted in real time or after recording via interfaces such as USB, Ethernet or wireless links. Export formats like CSV or Excel support trend evaluation, reporting and fault analysis.
How are calibration and maintenance handled?
Regular calibration is important for reliable long-term accuracy. Sensors and inputs should be checked periodically, and calibration intervals should follow the requirements of the application.
Where are multi-parameter loggers typically used?
They are commonly used in research and development, test benches, industrial process monitoring, environmental and building technology, as well as energy and electrical system analysis.












































































































































































Datasheet
Datasheet
Datasheet