IPAQ-R460 4-wire transmitter for resistance thermometers and thermocouples configurable via software or DIP switches


  • Easy configuration via DIP switch or via INOR-Set
  • Switchable service functions for easy commissioning
  • 3-port isolation
    Protection against measurement errors due to earthing problems and interference voltage carry-over
  • Extremely slim design 6.2 mm narrow bayed housing for simple and space-saving top-hat rail mounting
  • Optional in-rail bus mounting rail connector allows fast and cost-effective installation
  • Safe isolation according to EN 61140 Protection of maintenance personnel and downstream equipment from impermissibly high voltage
Datasheet
Flyer
User Manual

IPAQ R460 is a programmable 4-wire (separately powered) transmitter. It converts Pt, Ni, KTY and TC sensor signals as well as potentiometer, resistor and mV signals to isolated standard signals.

It is possible to configure IPAQ R460 with DIP switches or with the software INOR-Set. With INOR-Set, IPAQ R460 can be configured via PC and the data records can be stored and documented. An additional power supply is not necessary during PC configuration.

The commissioning function, which can be switched on at the front, generates a reference signal at the output with which the subsequent signal path can be tested and adjusted.

The Power supply can be supplied via the connection terminals or via the In-Rail-Bus connector. The supply voltage and error status are indicated by LEDs on the front of the unit.

 

 

Technical Specification

Type Rail-mounted
Input RTD, Thermocouple, mV, ohm and KTY
Input RTD Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni500, Ni1000
Input Thermocouple Typ B, E, J, K, L, N, R, S, T, U, W5Re_W26Re, W3Re_W25Re;
Measuring range RTD Pt 100, Pt 200, Pt 500, Pt 1000: -200… +850 °C

Ni 100: -60… +250 °C

Ni 200, Ni 500, Ni 1000: -50… 180 °C

Measuring range Thermocouple Type B: +250… +1820 °C

Type C (W5Re_W26Re): 0… +2315 °C

Type D (W3Re_W25Re): 0… +2315 °C

Type E: +270… +1000 °C

Type J: +210… +1200 °C

Type K: +200… +900 °C

Type L: +200… +900 °C

Type N: +270… +1300 °C

Type R: -50… +1768 °C

Type S: -50… +1768 °C

Type T: -270… +400 °C

Type U: +200… +600 °C

Type of Transmitter Digital
Output  0…20 mA, 4…20 mA, 0…10 mA, 2…10 mA,
0…5 V, 0…10 V, 1…5 V, 2…10 V
Galvanic isolation 3 kV AC, 50 Hz, 1 min
Measuring channels 1 channel
Sensor connection 2-, 3-, 4-wire
Power supply 24 V DC
Voltage range 9.6…31.2 VDC, approx. 0.8 W
Typical accuracy Max. ±0.05 K or ±0.05 % of measuring range
Configuration DIP switch or INOR-Set
EMC EN 61326-1
Ambient temperature Operation: -25…+70 °C (-13…+158 °F)
Transport and storage: -40…+85 °C (-40…+185 °F)
Design  6.2 mm:n (0.244″) bayed case, protection class IP 20, mounting on 35 mm top-hat rail acc. to EN 60715
Weight approx. 70 g








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    IPAQ-R460 4-wire transmitter for resistance thermometers and thermocouples configurable via software or DIP switches

    • Easy configuration via DIP switch or via INOR-Set
    • Switchable service functions for easy commissioning
    • 3-port isolation
      Protection against measurement errors due to earthing problems and interference voltage carry-over
    • Extremely slim design 6.2 mm narrow bayed housing for simple and space-saving top-hat rail mounting
    • Optional in-rail bus mounting rail connector allows fast and cost-effective installation
    • Safe isolation according to EN 61140 Protection of maintenance personnel and downstream equipment from impermissibly high voltage
    Datasheet
    Flyer
    User Manual

    IPAQ R460 is a programmable 4-wire (separately powered) transmitter. It converts Pt, Ni, KTY and TC sensor signals as well as potentiometer, resistor and mV signals to isolated standard signals.

    It is possible to configure IPAQ R460 with DIP switches or with the software INOR-Set. With INOR-Set, IPAQ R460 can be configured via PC and the data records can be stored and documented. An additional power supply is not necessary during PC configuration.

    The commissioning function, which can be switched on at the front, generates a reference signal at the output with which the subsequent signal path can be tested and adjusted.

    The Power supply can be supplied via the connection terminals or via the In-Rail-Bus connector. The supply voltage and error status are indicated by LEDs on the front of the unit.

     

     

    Technical Specification

    Type Rail-mounted
    Input RTD, Thermocouple, mV, ohm and KTY
    Input RTD Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni500, Ni1000
    Input Thermocouple Typ B, E, J, K, L, N, R, S, T, U, W5Re_W26Re, W3Re_W25Re;
    Measuring range RTD Pt 100, Pt 200, Pt 500, Pt 1000: -200… +850 °C

    Ni 100: -60… +250 °C

    Ni 200, Ni 500, Ni 1000: -50… 180 °C

    Measuring range Thermocouple Type B: +250… +1820 °C

    Type C (W5Re_W26Re): 0… +2315 °C

    Type D (W3Re_W25Re): 0… +2315 °C

    Type E: +270… +1000 °C

    Type J: +210… +1200 °C

    Type K: +200… +900 °C

    Type L: +200… +900 °C

    Type N: +270… +1300 °C

    Type R: -50… +1768 °C

    Type S: -50… +1768 °C

    Type T: -270… +400 °C

    Type U: +200… +600 °C

    Type of Transmitter Digital
    Output  0…20 mA, 4…20 mA, 0…10 mA, 2…10 mA,
    0…5 V, 0…10 V, 1…5 V, 2…10 V
    Galvanic isolation 3 kV AC, 50 Hz, 1 min
    Measuring channels 1 channel
    Sensor connection 2-, 3-, 4-wire
    Power supply 24 V DC
    Voltage range 9.6…31.2 VDC, approx. 0.8 W
    Typical accuracy Max. ±0.05 K or ±0.05 % of measuring range
    Configuration DIP switch or INOR-Set
    EMC EN 61326-1
    Ambient temperature Operation: -25…+70 °C (-13…+158 °F)
    Transport and storage: -40…+85 °C (-40…+185 °F)
    Design  6.2 mm:n (0.244″) bayed case, protection class IP 20, mounting on 35 mm top-hat rail acc. to EN 60715
    Weight approx. 70 g








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.