• Measure or source 0 to 24 mA
  • Accuracy: 0.01 % of reading +1 digit
  • Dual display of mA and %, linear or flow-based
  • Test modes: Step, Span, Valve test, Ramp
  • 30 V DC measurement and continuity check
  • Stores up to 100,000 readings
  • Integrated 250-ohm resistor for HART protocol support
  • 24 V DC loop supply in both measure and source modes
  • Auto power-off to extend battery life
Datasheet
Flyer

  • Multi-function capabilities: electrical, frequency, temperature, and pressure
  • Optional HART and Foundation Fieldbus communicators
  • ATEX, IECEx, and ETL approved for use in hazardous areas
  • Modular, reconfigurable, and expandable design
  • Individual components can also be used as stand-alone instruments
  • Enables significant reduction in equipment inventory
  • Simplifies training and enhances operator safety
  • Reduces cost of ownership
  • Includes a free license for 4Sight2 Lite calibration software
  • *Bluetooth connectivity for wireless communication
Datasheet
User Manual
ATEX Certifikate

  • Pressure ranges from 25 mbar to 700 bar (10 inH₂O to 10,000 psi)
  • Single or dual-range sensor configuration
  • mA measurement, switch test, and 24 V loop power supply
  • Large backlit display with intuitive, menu-driven interface
  • Integrated HART® resistor for digital communication
  • Robust and weatherproof design
  • Compact, user-friendly, and easily portable
  • Convenient one-handed operation with secure grip and impact-resistant elastomer protection
  • Plug-and-play compatibility with universal pressure modules (IUPM/IUPMP), accuracy up to 0.05% FS (total) or 0.01% FS (precision)
  • Programmable leak test for automatic leak rate detection
  • Advanced functions including hold, min/max/average values, alarm, and tare for efficient troubleshooting
Datasheet
User Manual

  • Pressure ranges from 25 mbar to 700 bar (10 inH₂O to 10,000 psi)
  • Single or dual-range configuration available
  • Simultaneous measurement of pressure and mA for calibration and maintenance of transmitters and control loops
  • 24 V loop power supply for energizing transmitters and control loops
  • Automatic switch test for rapid and accurate detection of switching points
  • Integrated, selectable HART® resistor (250 Ω) for easy communication with HART devices
  • Large backlit display with intuitive, menu-driven operation
  • Robust and weatherproof housing designed for demanding conditions
  • Compact, user-friendly, and easily portable
  • One-handed operation with secure grip and impact-resistant elastomer protection
  • Plug-and-play compatibility with universal pressure modules (IUPM/IUPMP), accuracy up to 0.05% FS total or 0.01% FS precision
  • Programmable leak test for automatic measurement of pressure drop and leak rate
  • Advanced features: hold, min/max/average values, alarm, and tare for efficient troubleshooting
Datasheet
User Manual

  • Sources and measures mA, mV, V, ohms, frequency, and pulses
  • Simulates and measures 8 RTD and 12 thermocouple types
  • 32 available pressure modules from 25 mbar to 700 bar (10 inH₂O to 10,000 psi)
  • Simultaneous dual-reading capability
  • Automatic switch test and pressure leak test
  • Data storage for 1000 measurement points with real-time clock
  • 24 V loop power supply
  • Integrated HART® loop resistor
  • Large backlit display
  • Robust and weatherproof
  • Compact, user-friendly, and easily portable
  • Convenient one-handed operation
  • Plug-and-play connection for universal IDOS pressure modules
Datasheet

Measuring counts  
TRMS  
AC/DC voltage 1000V anche AC+DC
AC/DC current 1A anche AC+DC
Resistance and buzzer continuity  
Diode test  
Frequency  
DC 4-20mA current measurement  
DC 0-10V voltage measurement  
DC 4-20mA current generation  
Measurement of output current of transducers  
Simulation of an external transducer  
Loop supply with minimum voltage 24V  
Generation of selectable ramp  
Load of 250Ω for testing HART transducers  
Backlit LCD display  
Autorange  
Auto Power OFF  
Data HOLD  
MIN/MAX function  
AVG function  
Relative measurement  
Protection category CAT IV
Weight in grams (batteries included)  
Size (LxWxH) (mm)
Datasheet

Measuring counts  
TRMS  
AC/DC voltage MAX 10VDC
AC/DC current MAX 24mADC
DC 4-20mA current measurement  
DC 0-10V voltage measurement  
DC 4-20mA current generation  
DC 0-10V voltage generation  
Measurement of output current of transducers  
Simulation of an external transducer  
Loop supply with minimum voltage 24V  
Generation of selectable ramp  
Backlit LCD display  
Auto power off  
Protection category  
Weight in grams (batteries included)  
Size (LxWxH) (mm)
Datasheet

  • Current Calibrator 0/4 - 22mA, Source/Sink
  • Voltage Calibrator 0-14V
  • mV Ranges 0-28mV and 0-560 mV
  • DIN Thermocouples J, K, N, R, S, T, B, E
  • Multimeter ±2V to ±200V DC and ±100mA
  • Simultaneous Calibration and Measurement
  • Steps, Ramps, direct entry
  • Built-in rechargeable Battery
Datasheet

  • Current Output 0-22mA, Source/Sink
  • Voltage Output 0-25V
  • mV Outputs 0-27mV and 0-540 mV
  • DIN Thermocouples J, K, N, R, S, T, B, E
  • RTD Simulator -200 … 850ºC
  • Resistance Range up to 3kOhm
  • Multimeter ±2V to ±200V DC and ±100mA
  • Measurements of fast Transients
  • Datalogger Function (Option)
  • 8 Tables with each 50 free Output Points
Datasheet

  • Measuring and  Sourcing loop current, mV, and V
  • Measuring and sourcing simultaneously
  • Loop integrity check capability
  • 24V loop supply with simultaneous current measurement
  • Three year warranty
  • ISO 17025-accredited calibration w/data included
No longer available
Datasheet

  • Accuracy to 0.01% of reading
  • Measure, source, or simulate loop current
  • Measure DC volts
  • Simultaneously mA and % span display
  • Switch functionality
  • Selectable ramp and step functions
  • HART 250Ω resistor in series with 24V loop
  • ISO 17025-accredited calibration w/data included
Datasheet
User Manual

  • Sourcing, simulating and measuring, temperature and electrical signals
  • Smartphone-like menu and interface make the operation simpler and easier
  • The internal cold junction compensation sensor can be re-calibrated  at ice point by users
  • Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)
  • ISO 17025-accredited calibration w/data included
No longer available
Datasheet

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Smartphone-like menu and interface make the operation simpler and easier
  • The internal cold junction compensation sensor can be re-calibrated at ice point by users
  • Ultra-compact, 3.9” x 7.6” x 2.0”, and 1.6 lb (0.7 kg)
  • ISO 17025-accredited calibration w/data included
Not available anymore! Successor model: ADT226 and ADT209/210
Datasheet

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Built-in Barometer
  • Intrinsically safe models available (Ex)
  • Large Smartphone like touchscreen user experience
  • USB Type-C and Bluetooth communications
  • IP67 Rated
  • High Voltage Measurement Capability (±300V AC)
  • True RMS Voltage Meter Capability
  • Dual channel pressure module ports
  • High Static Differential Pressure Measurement 0.002% FS
  • ISO 17025-accredited calibration w/data included
Datasheet
External Pressure Modules

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Built-in Barometer
  • Intrinsically safe models available (Ex)
  • Large Smartphone like touchscreen user experience
  • USB Type-C and Bluetooth communications
  • IP67 Rated
  • High Voltage Measurement Capability (±300V AC)
  • True RMS Voltage Meter Capability
  • Dual channel pressure module ports
  • High Static Differential Pressure Measurement 0.002% FS
  • ISO 17025-accredited calibration w/data included
Datasheet
External Pressure Modules
ATEX Certificate

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Built-in Full Hart Communicator (ADT227-HART)
  • Built-in Barometer
  • Intrinsically safe models available (Ex)
  • Large Smartphone Like Touchscreen User Experience
  • USB Type-C and Bluetooth communications
  • IP67 Rated
  • High Voltage Measurement Capability (±300V AC)
  • True RMS Voltage Meter Capability
  • Dual channel pressure module ports
  • High Static Differential Pressure Measurement 0.002% FS
  • ISO 17025-accredited calibration w/data included
Datasheet
External Pressure Modules

  • Sourcing, simulating and measuring pressure, temperature and electrical signals
  • Built-in Full Hart Communicator (ADT227-HART)
  • Built-in Barometer
  • Intrinsically safe models available (Ex)
  • Large Smartphone Like Touchscreen User Experience
  • USB Type-C and Bluetooth communications
  • IP67 Rated
  • High Voltage Measurement Capability (±300V AC)
  • True RMS Voltage Meter Capability
  • Dual channel pressure module ports
  • High Static Differential Pressure Measurement 0.002% FS
  • ISO 17025-accredited calibration w/data included
Datasheet
External Pressure Modules
ATEX Certificate

  • Measurement and simulation of the following parameters: pressure, electrical signals (mA, mV, V, Ω), temperature (TC, RTD), frequency and pulse
  • Large colour touchscreen display with new intuitive and user-friendly interface
  • Internal pressure/vacuum generation
  • Option: intrinsically safe version, II 2G Ex ib IIC T4 Gb - Tamb: -10 ... +50 °C
  • Option: integrated HART® module for communication with HART® instruments



Datasheet
User Manual
User Manual
User Manual

Compact and simple to use, the C.A 1623 calibrator is capable of measuring and simulating up to 7 different probes as well as a resistance. When used as a battery-powered stand-alone instrument, it offers a long battery life in the field. When connected to the mains, it can be used continuously without any time limit!

Datasheet

The compact, simple-to-use C.A 1621 thermocouple temperature calibrator is capable of measuring and simulating up to 8 types of thermocouples, as well as a voltage in mV. When used as a battery-powered stand-alone instrument, it offers a long battery life in the field. When connected to the mains, it can be used continuously without any time limit!

Datasheet

Compact and simple to use, the C.A 1631 calibrator is equipped with a wide screen for comfortable reading.. The C.A 1631 can be used to measure and supply a DC current loop from 0 to 24 mA with 0.015% accuracy and a DC voltage between 0 and 20 V with an accuracy of +/- 0.02 %. When used as a battery-powered stand-alone instrument, it offers a long battery life in the field. When connected to the mains, it can be used continuously without any time limit!

Datasheet


Process Calibrators – loop, temperature, pressure & field comms under control

Process calibrators are multi-function instruments to measure, source and simulate 4–20 mA, mV/V, Ω, RTD/TC, Hz/pulse and—depending on model—pressure (via modules) and field protocols (HART, sometimes Modbus, Profibus PA). They shorten downtime and streamline loop checks, commissioning and periodic verification in maintenance, QA and calibration labs.

Key capabilities (model-dependent): source/measure (SINK/SOURCE), 24 V loop power, ramp/step, automated procedures, documentation (as-found/as-left), communicator (HART DD/DDL), integrated pressure or pressure modules, USB/Bluetooth, IP protection and long battery life.

ICS Schneider Messtechnik advises on instrument selection, workflows, pressure modules, uncertainty budgets and software integration—including factory/DAkkS certificates.



FAQ on Process Calibrators

Answers on functions, accuracy, HART, pressure modules, loop tests, documentation, safety and best practices.

Which signals do process calibrators cover?

CategoryMeasureSource/SimulateTypical use
Current0/4–20 mA0/4–20 mA, step/rampTransmitters, loop checks
VoltagemV/VmV/VIndicators, I/O cards
ResistanceΩΩ (potentiometer)Input cards, sensor sim
RTDPt100/500/1000…RTD simulation (2/3/4-wire)Temp transmitters
ThermocoupleTypes K/J/T/N…TC simulation (CJC)TC chains
FrequencyHz/pulseHz/pulse (K-factor)Flow/RPM inputs
Pressureintegrated/modulePressure TX/switches

What’s the difference between SOURCE, MEASURE and LOOP?

SOURCE = output a signal; MEASURE = read a signal; LOOP = provide 24 V loop power while measuring/controlling current—ideal for loop-powered transmitters.

What accuracy is realistic?

Quality units achieve for 4–20 mA typically ±(0.015…0.05 % of rdg + counts). Temperature/TC simulation specs are range-dependent and include CJC effects.

Why use automatic ramps/steps?

Defined 0–100–0 % sweeps or 25 % steps speed up linearity and limit tests while keeping hands free for adjustments.

Do the instruments support HART?

Many models include a HART communicator (DD/DDL): set tag/range, damping, run diagnostics, loop test, burst, trim—often with a switchable 250 Ω resistor.

How do I calibrate a 4–20 mA transmitter?

  1. Set the calibrator to LOOP (24 V) + mA measurement.
  2. Simulate the input (e.g., RTD/TC/mV).
  3. Adjust zero/span on the transmitter and document as-found/as-left.

What should I consider for RTD simulation?

Wire correctly for 2/3/4-wire; compensate lead resistance; consider the input’s test current (self-heating).

How do I simulate thermocouples correctly?

Select the proper TC type and enable CJC (internal) or specify an external reference; maintain clean, polarity-correct connections.

Can I check pressure transmitters with a process calibrator?

Yes—using pressure modules or built-in sensors (to measure pressure) and simultaneously source mA/Hz for characterization; add pneumatic or hydraulic hand pumps for generation.

What are frequency/pulse outputs useful for?

Simulating flow pick-offs (K-factor) or RPM—handy for counter/PLC input tests.

How do I document in a compliant way?

Use a documenting calibrator and/or calibration software: capture as-found/as-left, test points, tolerance verdict, traceability chain, and export CSV/PDF with optional e-signature/audit trail.

Which interfaces are common?

USB, sometimes Bluetooth or LAN. Drivers/SCPI/protocols vary by model; companion apps/PC software handle job lists and reports.

How do I select the right pressure modules?

By range (mbar…bar), accuracy, medium (gas/liquid), overload, thread and temperature rating. For differential use, consider dual-port manifolds.

What power do I need for loop tests?

Many calibrators supply 24 V with an integrated, switchable 250 Ω HART resistor. Alternatively use an external PSU plus the calibrator in MEASURE mode.

How do I plan an uncertainty budget?

Combine calibrator accuracy, resolution, drift, environment (T/RH), lead/contact errors and any module uncertainty; report expanded with k=2.

What robustness/IP rating makes sense?

For field work choose IP54–IP65, rubberised housing, shock protection, bright display and glove-friendly keys. For labs, prioritize fine resolution and stability.

Common pitfalls—how to avoid them?

  • Wrong mode (mA MEASURE vs. SOURCE).
  • Missing CJC on TC tests.
  • Incorrect wire count on RTD.
  • No 250 Ω in the HART loop.
  • Loose terminals causing lead/contact errors.

How often should a process calibrator be recalibrated?

Typically annually; shorten intervals for critical QA or heavy use. After repair/shock, perform an interim verification.

Do you support selection & integration?

Yes—we recommend devices/modules, define procedures, connect software to CMMS/QMS and supply factory/DAkkS certificates.

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.