ICS 02S Simulator for Pt-100 | RTD | TC | mV/V


  • Measurement and simulation of RTD, TC and V signals
  • Up to 0.05% accuracy
  • Data memory
  • Automatic zero
  • Ambient temperature display
  • HD digital display, 5½ digits with backlight
  • Integrated flashlight
Datasheet
User Manual

ICS-02S – Compact Temperature Calibrator & Simulator for Field & Lab

The ICS-02S combines measurement and simulation of RTD, thermocouple, and mV/V signals in a handy instrument.
With a basic accuracy of ±0.05%, a backlit 5½-digit display, and an integrated reference junction, it is ideal for
commissioning, maintenance, and on-site calibration work. Four safety sockets (one channel) plus practical accessories
(4 mm safety leads, crocodile clips, TC reference junction plug) come as standard. Power is supplied by 4 × AAA cells,
providing up to 25 h of operation with auto power-off. Housing and scope of delivery are geared towards mobile use.

At a glance:

  • RTD (Pt100/200/500/1000, Cu50): Source & measure −200…+800 °C (0.1 °C resolution), 2/3/4-wire measurement, resistance up to 5.5 kΩ with up to 0.01 Ω resolution.
  • Thermocouples R, S, K, E, J, T, N, B, A, C, D: source/measure in °C/°F or as mV (source −100…1100 mV, measure 50…550 mV). Internal reference junction ±0.5 °C.
  • Voltage: source/measure −10 mV…1.1 V or −35…+35 V DC (±0.05%). Audible continuity test incl. “open” threshold 0.5 kΩ.
  • Ergonomics: large, high-contrast display and simple keypad navigation in a robust ABS housing (210 × 100 × 40 mm, approx. 550 g).

Typical applications:

  • Calibration and service of transmitters
  • Controllers and indicators, field troubleshooting
  • Temperature simulation during commissioning
  • Training and QA test benches

Technical Data – ICS-02S
Type ICS-02S
Resistance Thermometer (RTD)
Generate & measure RTD signals Pt100, Pt200, Pt500, Pt1000, Cu50 (−200…0…+800 °C); 0.1 °C
Resistance / Source / Measure 0…4000 Ω or 0…5500 Ω; 0.1 Ω or 0.01 Ω
Accuracy (rdg + const.) ±0.05%
Selectable temperature unit °C / °F
Multi-wire measurement 2 / 3 / 4
Thermocouples (TC)
Generate & measure TC signals R, S, K, E, J, T, N, B, A, C, D
mV source / mV measure −100…1100 mV / 50…550 mV
Also source/measure in °C Yes
Accuracy (rdg + const.) ±0.05%
Selectable temperature unit °C / °F
Internal reference junction ±0.5 °C
Voltage (V)
Generate & measure voltage −10 mV…1.1 V or −35…+35 V DC
Accuracy (rdg + const.) ±0.05%
Continuity (O/C) O / C
Audible continuity O / C
“Open” threshold 0.5 kΩ
Features
Sensor connector 4 safety sockets (1 channel) incl. 2 sets of 4 mm safety test leads and crocodile clips; TC reference junction plug
Power supply 4 × 1.5 V AAA batteries; operating time approx. 25 h; with auto power-off
User interface Keypad
Display Multi-function LCD, 5½-digit, backlit
Housing
Design / scope of delivery ABS housing with protective padding; set of safety leads; crocodile clips; TC reference junction; manual; test certificate
Dimensions (H × W × D) 210 × 100 × 40 mm
Weight approx. 550 g








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    ICS 02S Simulator for Pt-100 | RTD | TC | mV/V

    • Measurement and simulation of RTD, TC and V signals
    • Up to 0.05% accuracy
    • Data memory
    • Automatic zero
    • Ambient temperature display
    • HD digital display, 5½ digits with backlight
    • Integrated flashlight
    Datasheet
    User Manual

    ICS-02S – Compact Temperature Calibrator & Simulator for Field & Lab

    The ICS-02S combines measurement and simulation of RTD, thermocouple, and mV/V signals in a handy instrument.
    With a basic accuracy of ±0.05%, a backlit 5½-digit display, and an integrated reference junction, it is ideal for
    commissioning, maintenance, and on-site calibration work. Four safety sockets (one channel) plus practical accessories
    (4 mm safety leads, crocodile clips, TC reference junction plug) come as standard. Power is supplied by 4 × AAA cells,
    providing up to 25 h of operation with auto power-off. Housing and scope of delivery are geared towards mobile use.

    At a glance:

    • RTD (Pt100/200/500/1000, Cu50): Source & measure −200…+800 °C (0.1 °C resolution), 2/3/4-wire measurement, resistance up to 5.5 kΩ with up to 0.01 Ω resolution.
    • Thermocouples R, S, K, E, J, T, N, B, A, C, D: source/measure in °C/°F or as mV (source −100…1100 mV, measure 50…550 mV). Internal reference junction ±0.5 °C.
    • Voltage: source/measure −10 mV…1.1 V or −35…+35 V DC (±0.05%). Audible continuity test incl. “open” threshold 0.5 kΩ.
    • Ergonomics: large, high-contrast display and simple keypad navigation in a robust ABS housing (210 × 100 × 40 mm, approx. 550 g).

    Typical applications:

    • Calibration and service of transmitters
    • Controllers and indicators, field troubleshooting
    • Temperature simulation during commissioning
    • Training and QA test benches

    Technical Data – ICS-02S
    Type ICS-02S
    Resistance Thermometer (RTD)
    Generate & measure RTD signals Pt100, Pt200, Pt500, Pt1000, Cu50 (−200…0…+800 °C); 0.1 °C
    Resistance / Source / Measure 0…4000 Ω or 0…5500 Ω; 0.1 Ω or 0.01 Ω
    Accuracy (rdg + const.) ±0.05%
    Selectable temperature unit °C / °F
    Multi-wire measurement 2 / 3 / 4
    Thermocouples (TC)
    Generate & measure TC signals R, S, K, E, J, T, N, B, A, C, D
    mV source / mV measure −100…1100 mV / 50…550 mV
    Also source/measure in °C Yes
    Accuracy (rdg + const.) ±0.05%
    Selectable temperature unit °C / °F
    Internal reference junction ±0.5 °C
    Voltage (V)
    Generate & measure voltage −10 mV…1.1 V or −35…+35 V DC
    Accuracy (rdg + const.) ±0.05%
    Continuity (O/C) O / C
    Audible continuity O / C
    “Open” threshold 0.5 kΩ
    Features
    Sensor connector 4 safety sockets (1 channel) incl. 2 sets of 4 mm safety test leads and crocodile clips; TC reference junction plug
    Power supply 4 × 1.5 V AAA batteries; operating time approx. 25 h; with auto power-off
    User interface Keypad
    Display Multi-function LCD, 5½-digit, backlit
    Housing
    Design / scope of delivery ABS housing with protective padding; set of safety leads; crocodile clips; TC reference junction; manual; test certificate
    Dimensions (H × W × D) 210 × 100 × 40 mm
    Weight approx. 550 g








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.