IUPM / IUPMP (IDOS) Universal Pressure Modules

from 1,418.00 €
plus VAT

  • Pressure ranges from 25 mbar to 700 bar (10 in H2O to 10,000 psi)
  • 0.05% FS all-inclusive accuracy
  • Optional 0.01% FS premium accuracy
  • Fully interchangeable, no set-up required
  • Impact resistant, elastomer protected
  • Robust, weatherproof and simple to use
Datasheet

Applications

  • Remote pressure sensor for (IDOS) compatible instruments, e.g. DPI 800 series and PACE
  • Use cases: test, measurement, monitoring and calibration
  • Expands instrument ranges and capabilities of existing equipment

IDOS Universal Pressure Modules (IUPM / IUPMP) are robust and easy to use.
The high-accuracy IDOS modules are housed in tough cases, providing high reliability and
plug-and-play connectivity. They offer a cost-effective solution for range expansion,
for adding a pressure measurement capability, and for addressing additional applications.

Compatible products

  • DPI 800 series (handheld indicators/calibrators) – indication, calibrate (measure/source), mA/loop-power, switch test, HART resistor, memory and more
  • IUPM / IUPMP – IDOS universal pressure modules for range expansion
  • PACE 1000 – precision pressure indicator (secondary standard), bench/panel mounted

IUPM/IUPMP – pressure ranges & accuracy

Pressure range G/D G A Media Accuracy %FS
Standard / Premium
25 mbar (±10 in H2O) G Non-corrosive gases 0.1 / 0.03
70, 200, 350, 700 mbar (±1, ±3, ±5, ±10 psi) G/D Non-corrosive gases 0.075 / 0.03
350 mbar (5 psi) G Non-corrosive gases 0.05 / 0.01
−1 to 1 or 2 bar (−15 to 15/30 psi) G/D Stainless-steel compatible media 0.05 / 0.01
2 bar (30 psi) G Stainless-steel compatible media 0.075 / N/A
−1 to 2, 7, 20 bar (−15 to 50, 100, 150 or 300 psi) G/D Stainless-steel compatible media 0.05 / 0.01
35, 70, 100, 135, 200 bar (500, 1000, 1500, 2000 psi) G Stainless-steel compatible media 0.05 / 0.01
350/700 bar (5000/10,000 psi) sealed gauge G Stainless-steel compatible media 0.05 / N/A

G = gauge, A = absolute, G/D = gauge/differential. Accuracy refers to %FS; premium not available for all ranges.

Specifications

IUPM standard accuracy
  • Total accuracy including calibration uncertainty, operation 0 °C to 50 °C (32 °F to 122 °F) and one-year stability
  • Negative calibration included
IUPMP premium accuracy
  • Precision from 18 °C to 28 °C (65 °F to 82 °F); for 5 °C to 45 °C (41 °F to 113 °F) 0.014% FS
  • 0.075% for ranges 25 to 700 mbar (10 in H2O to 10 psi)
  • Stability 0.01% of reading/year (0.03% for 25–350 mbar / 10 in H2O to 5 psi)
  • Calibration uncertainty 50 ppm of reading
  • Optional negative calibration
Overpressure (maximum transient/intermittent)
  • ≤ 350 mbar (5 psi): 4 × FS
  • 700 mbar to 700 bar (10 psi to 10,000 psi): 2 × FS
  • Maximum working pressure: 1.1 × FS
Pressure connections
  • G 1/8" female
  • M5 reference on G ranges above 2 bar (30 psi)
  • 1/8" NPT female
  • 10-32 UNF reference on G ranges ≤ 2 bar (30 psi)
Electrical connection
  • 1 m (3 ft) cable with locking connector
Operating temperature
  • −10 °C to +50 °C (14 °F to 122 °F)
Storage temperature
  • −20 °C to +70 °C (−4 °F to 158 °F)
Humidity
  • 0 to 90% RH, non-condensing (Def Stan 66-31, 8.6 Cat III)
Shock & vibration
  • BS EN 61010
  • Def Stan 66-31, 8.18 and 8.6 Cat III
EMC
  • EN 61326-1
Electrical safety
  • EN 61010-1
Pressure safety
  • Pressure Equipment Directive – Class: Sound Engineering Practice (SEP)
Approvals
  • CE marked
Size
  • 130 mm × 60 mm × 45 mm (5 in × 2.3 in × 1.7 in)
Weight
  • 240 to 325 g (0.53 to 0.71 lbs)
Options
  • Negative calibration (A) for ranges ≤ 20 bar (300 psi)
  • Refer to the “Pressure ranges” table for available ranges & accuracies









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    IUPM / IUPMP (IDOS) Universal Pressure Modules

    from 1,418.00 €
    plus VAT
    • Pressure ranges from 25 mbar to 700 bar (10 in H2O to 10,000 psi)
    • 0.05% FS all-inclusive accuracy
    • Optional 0.01% FS premium accuracy
    • Fully interchangeable, no set-up required
    • Impact resistant, elastomer protected
    • Robust, weatherproof and simple to use
    Datasheet

    Applications

    • Remote pressure sensor for (IDOS) compatible instruments, e.g. DPI 800 series and PACE
    • Use cases: test, measurement, monitoring and calibration
    • Expands instrument ranges and capabilities of existing equipment

    IDOS Universal Pressure Modules (IUPM / IUPMP) are robust and easy to use.
    The high-accuracy IDOS modules are housed in tough cases, providing high reliability and
    plug-and-play connectivity. They offer a cost-effective solution for range expansion,
    for adding a pressure measurement capability, and for addressing additional applications.

    Compatible products

    • DPI 800 series (handheld indicators/calibrators) – indication, calibrate (measure/source), mA/loop-power, switch test, HART resistor, memory and more
    • IUPM / IUPMP – IDOS universal pressure modules for range expansion
    • PACE 1000 – precision pressure indicator (secondary standard), bench/panel mounted

    IUPM/IUPMP – pressure ranges & accuracy

    Pressure range G/D G A Media Accuracy %FS
    Standard / Premium
    25 mbar (±10 in H2O) G Non-corrosive gases 0.1 / 0.03
    70, 200, 350, 700 mbar (±1, ±3, ±5, ±10 psi) G/D Non-corrosive gases 0.075 / 0.03
    350 mbar (5 psi) G Non-corrosive gases 0.05 / 0.01
    −1 to 1 or 2 bar (−15 to 15/30 psi) G/D Stainless-steel compatible media 0.05 / 0.01
    2 bar (30 psi) G Stainless-steel compatible media 0.075 / N/A
    −1 to 2, 7, 20 bar (−15 to 50, 100, 150 or 300 psi) G/D Stainless-steel compatible media 0.05 / 0.01
    35, 70, 100, 135, 200 bar (500, 1000, 1500, 2000 psi) G Stainless-steel compatible media 0.05 / 0.01
    350/700 bar (5000/10,000 psi) sealed gauge G Stainless-steel compatible media 0.05 / N/A

    G = gauge, A = absolute, G/D = gauge/differential. Accuracy refers to %FS; premium not available for all ranges.

    Specifications

    IUPM standard accuracy
    • Total accuracy including calibration uncertainty, operation 0 °C to 50 °C (32 °F to 122 °F) and one-year stability
    • Negative calibration included
    IUPMP premium accuracy
    • Precision from 18 °C to 28 °C (65 °F to 82 °F); for 5 °C to 45 °C (41 °F to 113 °F) 0.014% FS
    • 0.075% for ranges 25 to 700 mbar (10 in H2O to 10 psi)
    • Stability 0.01% of reading/year (0.03% for 25–350 mbar / 10 in H2O to 5 psi)
    • Calibration uncertainty 50 ppm of reading
    • Optional negative calibration
    Overpressure (maximum transient/intermittent)
    • ≤ 350 mbar (5 psi): 4 × FS
    • 700 mbar to 700 bar (10 psi to 10,000 psi): 2 × FS
    • Maximum working pressure: 1.1 × FS
    Pressure connections
    • G 1/8" female
    • M5 reference on G ranges above 2 bar (30 psi)
    • 1/8" NPT female
    • 10-32 UNF reference on G ranges ≤ 2 bar (30 psi)
    Electrical connection
    • 1 m (3 ft) cable with locking connector
    Operating temperature
    • −10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature
    • −20 °C to +70 °C (−4 °F to 158 °F)
    Humidity
    • 0 to 90% RH, non-condensing (Def Stan 66-31, 8.6 Cat III)
    Shock & vibration
    • BS EN 61010
    • Def Stan 66-31, 8.18 and 8.6 Cat III
    EMC
    • EN 61326-1
    Electrical safety
    • EN 61010-1
    Pressure safety
    • Pressure Equipment Directive – Class: Sound Engineering Practice (SEP)
    Approvals
    • CE marked
    Size
    • 130 mm × 60 mm × 45 mm (5 in × 2.3 in × 1.7 in)
    Weight
    • 240 to 325 g (0.53 to 0.71 lbs)
    Options
    • Negative calibration (A) for ranges ≤ 20 bar (300 psi)
    • Refer to the “Pressure ranges” table for available ranges & accuracies









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.