Potentiometer Transmitter DR 4310 – Isolation and Conversion of Potentiometer Position Signals


The Potentiometer Transmitter DR 4310 is used for isolation and conversion of potentiometer position signals.

  • Easy configuration
    Conversion of potentiometric position signals without range selection
  • Universal power supply for 20 to 253 V AC/DC
    Applicable world-wide for all common supply voltages
  • 3-port isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Ultra small sized housing
    12.5 mm housing with plug-in screw terminal blocks
  • High bandwidth; high accuracy
    No distortion; no falsification of measured signal
  • Protective Separation
    Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability
    No maintenance costs
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet

Due to the easy configuration, the new universal power pack and the ultra-small housing the Isolation Amplifier is suitable for flexible use.

The ratiometric measuring method allows the acquisition of potentiometer signals without range selection. Unipolar and bipolar output signals can be selected with a DIP switch. Subsequent readjustment or measured range compensation can then be performed at the zero/scan potentiometers on the front panel.

The small housing with 12.5 mm width saves space in your switch cabinet and facilitates by the practical plug-in screw terminal blocks the assembly. For range setting a simple housing unblocking is installed which makes it possible to reach easily all control elements on the mounting rail.

The new universal power pack for 20 … 253 V AC/DC means the DR 4310 can be used anywhere in the world, with all mains power supplies. The unit’s high efficiency contributes significantly to reducing the unit’s own heat generation. This is reflected in extremely high reliability and long-term stability. A green LED on the front of the unit has been provided to monitor the power supply.

Product line

Devices Order No.
Potentiometer Transmitter, configurable DR 4310 AG

 

Technical Data

Input

Input Signal Potentiometer 100 Ohm to 100 kOhm
Sensor supply 1.2 V (limited to max. 5 mA)
Potentiometer connection 3 wire connection
Input resistance > 10 MOhm

Output

Voltage Current
Output signals
(switch selectable)
± 10 V, 0 to 10 V, 2 to 10 V
± 5 V, 0 to 5 V, 1 to 5 V
± 20 mA, 0 to 20 mA, 4 to 20 mA
± 10 mA, 0 to 10 mA, 2 to 10 mA
Load ≤ 10 mA (1 kOhm at 10 V) ≤ 12 V (600 Ohm at 20 mA)
Linear transmission range unipolar: –2 to +110 %, bipolar: –110 to +110 %
Residual ripple < 10 mV rms

General Data

Transmission error < 0.1 % full scale
Temperature coefficient 1) < 100 ppm/K
Zero/Span compensation Start value 0 to 20 %; End value: 80 to 100 %
Minimum span: 80 %
Cut-off frequency -3 dB 1 kHz, switchable to 30 Hz
Response time T99 0.8 ms,      20 ms
Test voltage 4 kV AC, 50 Hz, 1 min., Input against output against
power supply
Working voltage 2)
(Basic Insulation)
600 V AC/DC for overvoltage category II and pollution
degree 2 acc. to EN 61010-1
Protection against
electrical shock 2)
Protective separation according to EN 61140 by reinforced
insulation in accordance with EN 61010-1 up to 600 V AC/DC
for overvoltage category II and pollution degree 2 between
all circuits.
Ambient temperature Operation
Transport and storage
–20 to +70 °C  (-4 to 158 °F)
–35 to +85 °C  (-31 to 185 °F)
Power supply 20 to 253 V AC/DC, AC 48 to 62 Hz, approx. 2 VA
DC approx. 1.0 W
EMC 3) EN 61326-1
Construction 12.5 mm (0.49″) housing, protection type: IP 20
mounting on 35 mm DIN rail acc. to EN 60715
Weight Approx. 100 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • 1Input, Wiper +
  • 2 −Input, Poti +
  • 3 +Input, Poti –
  • 4
  • 5 +Output
  • 6 −Output
  • 7Power supply AC/DC
  • 8Power supply AC/DC

Pluggable screw clamp terminals
Wire cross-section max. 2.5 mm², Multi-wire connection max. 1 mm² (two wires with same cross-section)









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Potentiometer Transmitter DR 4310 – Isolation and Conversion of Potentiometer Position Signals

    The Potentiometer Transmitter DR 4310 is used for isolation and conversion of potentiometer position signals.

    • Easy configuration
      Conversion of potentiometric position signals without range selection
    • Universal power supply for 20 to 253 V AC/DC
      Applicable world-wide for all common supply voltages
    • 3-port isolation
      Protection against erroneous measurements due to parasitic voltages or ground loops
    • Ultra small sized housing
      12.5 mm housing with plug-in screw terminal blocks
    • High bandwidth; high accuracy
      No distortion; no falsification of measured signal
    • Protective Separation
      Protects service personnel and downstream devices against impermissibly high voltage
    • Maximum reliability
      No maintenance costs
    • 5 Years Warranty
      Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
    Datasheet

    Due to the easy configuration, the new universal power pack and the ultra-small housing the Isolation Amplifier is suitable for flexible use.

    The ratiometric measuring method allows the acquisition of potentiometer signals without range selection. Unipolar and bipolar output signals can be selected with a DIP switch. Subsequent readjustment or measured range compensation can then be performed at the zero/scan potentiometers on the front panel.

    The small housing with 12.5 mm width saves space in your switch cabinet and facilitates by the practical plug-in screw terminal blocks the assembly. For range setting a simple housing unblocking is installed which makes it possible to reach easily all control elements on the mounting rail.

    The new universal power pack for 20 … 253 V AC/DC means the DR 4310 can be used anywhere in the world, with all mains power supplies. The unit’s high efficiency contributes significantly to reducing the unit’s own heat generation. This is reflected in extremely high reliability and long-term stability. A green LED on the front of the unit has been provided to monitor the power supply.

    Product line

    Devices Order No.
    Potentiometer Transmitter, configurable DR 4310 AG

     

    Technical Data

    Input

    Input Signal Potentiometer 100 Ohm to 100 kOhm
    Sensor supply 1.2 V (limited to max. 5 mA)
    Potentiometer connection 3 wire connection
    Input resistance > 10 MOhm

    Output

    Voltage Current
    Output signals
    (switch selectable)
    ± 10 V, 0 to 10 V, 2 to 10 V
    ± 5 V, 0 to 5 V, 1 to 5 V
    ± 20 mA, 0 to 20 mA, 4 to 20 mA
    ± 10 mA, 0 to 10 mA, 2 to 10 mA
    Load ≤ 10 mA (1 kOhm at 10 V) ≤ 12 V (600 Ohm at 20 mA)
    Linear transmission range unipolar: –2 to +110 %, bipolar: –110 to +110 %
    Residual ripple < 10 mV rms

    General Data

    Transmission error < 0.1 % full scale
    Temperature coefficient 1) < 100 ppm/K
    Zero/Span compensation Start value 0 to 20 %; End value: 80 to 100 %
    Minimum span: 80 %
    Cut-off frequency -3 dB 1 kHz, switchable to 30 Hz
    Response time T99 0.8 ms,      20 ms
    Test voltage 4 kV AC, 50 Hz, 1 min., Input against output against
    power supply
    Working voltage 2)
    (Basic Insulation)
    600 V AC/DC for overvoltage category II and pollution
    degree 2 acc. to EN 61010-1
    Protection against
    electrical shock 2)
    Protective separation according to EN 61140 by reinforced
    insulation in accordance with EN 61010-1 up to 600 V AC/DC
    for overvoltage category II and pollution degree 2 between
    all circuits.
    Ambient temperature Operation
    Transport and storage
    –20 to +70 °C  (-4 to 158 °F)
    –35 to +85 °C  (-31 to 185 °F)
    Power supply 20 to 253 V AC/DC, AC 48 to 62 Hz, approx. 2 VA
    DC approx. 1.0 W
    EMC 3) EN 61326-1
    Construction 12.5 mm (0.49″) housing, protection type: IP 20
    mounting on 35 mm DIN rail acc. to EN 60715
    Weight Approx. 100 g
    1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
    2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
    3. Minor deviations possible during interference

    Block diagram

    Dimensions

    Terminal assignments

    • 1Input, Wiper +
    • 2 −Input, Poti +
    • 3 +Input, Poti –
    • 4
    • 5 +Output
    • 6 −Output
    • 7Power supply AC/DC
    • 8Power supply AC/DC

    Pluggable screw clamp terminals
    Wire cross-section max. 2.5 mm², Multi-wire connection max. 1 mm² (two wires with same cross-section)









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.