Additel 762 Automated Hydraulic Pressure Calibrator


  • Automated pressure generation and control to 10,000 psi (700 Bar)
  • Accuracy to 0.01%FS
  • Dual-range manual or auto select
  • Control stability 0.005%FS
  • Portable – designed for use in the field and in the lab
  • Control by optional external pressure modules
  • Supports two external pressure modules
  • Wi-Fi, LAN, Bluetooth, USB and Ethernet communication
  • Full HART field communicator
  • HART and PROFIBUS communication
  • Data logging and task management
  • Patented electric pump technology
Datasheet
Videos

The Additel 762 Automated Pressure Calibrator is unlike any other pressure calibrator on the market.  This revolutionary product is a complete turnkey solution for automation of pressure calibration work up to 10,000 PSI.

Designed for use in both the field and the laboratory, the portability and accuracy of this state-of-the-art product will quickly become the favorite go-to calibrator for lab personnel and field technicians alike.

With fully automated support for calibration of pressure transmitters, switches, dial and digital gauges and sensors, including HART/PROFIBUS devices in conjunction with a fully integrated task feature, data collection and Wi-Fi connectivity, we had our customer’s needs in mind when designing our most capable pressure calibrator to date.

Description
Dual-Range Accuracy to 0.01% FS
The ADT762 includes the unique ability to automatically switch between different internal calibrations depending on the current control pressure of the ADT762. Additel provides calibrations unique to each ADT762 for ranges of 0-3,000 PSI (200 Bar) and 0-10,000 PSI (700 Bar). As the calibrator is pressurized, it will automatically select the best calibration data for any specific control pressure. This means the accuracy option of 0.01% or 0.02% FS would apply to both the 10,000 psi and the 3,000 psi ranges. Pressure calibration range selection can be set to “auto” mode so the calibration range is automatically selected by the ADT762 based on the set point pressure, or the calibration range can be manually selected.
Built-in Auto-Purge Application
Purging hydraulic calibration systems can be challenging and time consuming. The ADT762 has been designed with an integrated auto-purge system that saves time, money and frustration by completely automating the removal of air from the system. With the push of a button, the ADT762 quickly manages the system purging. This helps to free up time for technicians to attend to other needs.
Documented Task Feature
The powerful documented calibration task application allows users to quickly create and execute tasks without the need for a PC or tablet. The ADT762 automatically analyzes errors, generates test reports, while storing results locally. The Additel 762 can support up to 1000 documented tasks which can be stored and recalled at any time to help save time and money.
Dual-Mode Hart Communication
HART pressure transmitters can be directly maintained and calibrated without any other equipment or tools. The ADT762 provides an automatic HART calibration mode as well as a manual mode. This dual-mode HART communication function not only provides an efficient and convenient interoperability mode for DUT, but also supports access to a fully HART capable calibrator.

 

Pressure Specifications
Pressure Range 0-10,000 psi (0-700 Bar)
Range Selection Manual 3K psi, Manual 10K psi or Auto-range
Accuracy 0-10,000 psi, 0.01%FS 0-10,000 psi, 0.02%FS
0-3,000 psi, 0.01%FS 0-3,000 psi, 0.02%FS
Maximum External Load Capacity Max: 80 ml @ 700 Bar, 50 ml reccomended
Reservoir Max: 350 ml, push-on reservoir cap, built-in filter
Control Stability [1] ≤ 0.005% FS
Stability Duration > 5 min
Pressure Modules Built-in one module with dual range
External Control Pressure Module See the following “External Control Pressure Module Specification and Compatibility” table
External Measurement Pressure Module All ADT161 pressure modules
[1] Control Stability is based on the range of pressure control module

 

Electrical Specifications
Specification Range Resolution Accuracy Note
Current Measure Auto-ranging ±25 or ±50 mA 0.1 μA 0.008 %RD + 1.0 μA Impedance < 10 Ω
0.008 %RD + 2.0 μA
Voltage Measure ±300 mV 1 μV 0.008 %RD + 6 μV Impedance > 1 GΩ
Auto-ranging ±5, ±12 or ±30 V ±5 V: 20 μV 0.008 %RD + 100 μV Impedance > 1 MΩ
±12 V: 0.1 mV 0.008 %RD + 240 μV
±30 V: 0.1 mV 0.008 %RD + 600 μV
Loop Power Source 24 V N/A ±1 V 50 mA (Max Loading)
mA Source 0 to 2.5 mA or 2.5 to 25 mA 0-2.5 mA: 0.05μA, 0-25 mA: 0.5μA 0-2.5 mA: 0.008 %RD + 0.1 μA, 0-25 mA: 0.008 %RD + 1.0 μA 20 mA @ 1 kΩ
Power Source 16 to 30 V 1 V ±1 V 70 mA (Max Loading)
V Source 0 to 16 V 250 μV 0.008 %RD + 0.002 %FS
Pressure Switch Mechanical Switch, Live Mechanical Switch, NPN Switch, PNP Switch N/A N/A Response time < 10 ms if the switch is powered. Voltage range: (3-30) V
Temperature Compensation 18°C to 28°C
Temperature Coefficient Outside of 18°C to 28°C: <±0.0005%RD+0.00005%FS/°C
Misuse Protection Up to 30 V on any two sockets
Pressure Switch Test Supported
HART / Profibus PA Supported

 

External Control Pressure Module Specification and Compatibility
Specification Pressure Range Accuracy Pressure Type Media
(psi) (bar)
ADT161-01RD-GPXM for 0.01% rdg





1000 70 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
1500 100 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
2000 140 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
3000 200 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
5000 350 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
10000 700 0.01% rdg or 0.03% FS whichever is greater Gauge G,L



ADT161-02-GPXX for 0.02% FS


1000 70 0.02 Gauge G,L
1500 100 0.02 Gauge G,L
2000 140 0.02 Gauge G,L
3000 200 0.02 Gauge G,L
5000 350 0.02 Gauge G,L
10000 700 0.02 Gauge G,L
[1] For 0.01% FS pressure modules, single or multiple measurement range calibration certificate per request.  For other specifications, please contact Additel for more details.

 

General Specifications
Specification Description
User Interface Color touch screen and keypad operation
Display 7” TFT touch screen 800 x 480 color
Enclosure IP Rating IP31
Power Dedicated lithium battery or power adapter
Battery Rechargeable Li-Ion battery, typically 12 hours of operation, less than 5 hours recharge.
Weight 28 lbs (12.8 kg) without media
Size 11.81 x 8.66 x 7.56 in (300 x 220 x 192 mm)
Communications Wi-Fi, LAN, Bluetooth, USB, Ethernet
HART Communication Read, configure and calibrate HART devices – DD files updated periodically
Data Storage > 8 GB
Data Logging Up to 1,000,000 readings (data and time stamped)
Task documentation Up to 1,000 tasks can be stored with data
Automation Functions Switch test, auto step, leak test
User Interface Localization English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
Pump life > 1,000,000 cycles
Environmental Specifications Operating temperature: 32°F to 122°F( 0°C to 50°C)
Storage temperature: -20°C to 60°C ( -4°F to 120°F)
Humidity: <90%, non-condensing
Certification ISO 17025 accredited certificate of calibration with NIST-traceable data
Compliance CE
Software Compatibility ACal, Additel Land and Additel Link for access via mobile application
Warranty 1 year








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Additel 762 Automated Hydraulic Pressure Calibrator

    • Automated pressure generation and control to 10,000 psi (700 Bar)
    • Accuracy to 0.01%FS
    • Dual-range manual or auto select
    • Control stability 0.005%FS
    • Portable – designed for use in the field and in the lab
    • Control by optional external pressure modules
    • Supports two external pressure modules
    • Wi-Fi, LAN, Bluetooth, USB and Ethernet communication
    • Full HART field communicator
    • HART and PROFIBUS communication
    • Data logging and task management
    • Patented electric pump technology
    Datasheet
    Videos

    The Additel 762 Automated Pressure Calibrator is unlike any other pressure calibrator on the market.  This revolutionary product is a complete turnkey solution for automation of pressure calibration work up to 10,000 PSI.

    Designed for use in both the field and the laboratory, the portability and accuracy of this state-of-the-art product will quickly become the favorite go-to calibrator for lab personnel and field technicians alike.

    With fully automated support for calibration of pressure transmitters, switches, dial and digital gauges and sensors, including HART/PROFIBUS devices in conjunction with a fully integrated task feature, data collection and Wi-Fi connectivity, we had our customer’s needs in mind when designing our most capable pressure calibrator to date.

    Description
    Dual-Range Accuracy to 0.01% FS
    The ADT762 includes the unique ability to automatically switch between different internal calibrations depending on the current control pressure of the ADT762. Additel provides calibrations unique to each ADT762 for ranges of 0-3,000 PSI (200 Bar) and 0-10,000 PSI (700 Bar). As the calibrator is pressurized, it will automatically select the best calibration data for any specific control pressure. This means the accuracy option of 0.01% or 0.02% FS would apply to both the 10,000 psi and the 3,000 psi ranges. Pressure calibration range selection can be set to “auto” mode so the calibration range is automatically selected by the ADT762 based on the set point pressure, or the calibration range can be manually selected.
    Built-in Auto-Purge Application
    Purging hydraulic calibration systems can be challenging and time consuming. The ADT762 has been designed with an integrated auto-purge system that saves time, money and frustration by completely automating the removal of air from the system. With the push of a button, the ADT762 quickly manages the system purging. This helps to free up time for technicians to attend to other needs.
    Documented Task Feature
    The powerful documented calibration task application allows users to quickly create and execute tasks without the need for a PC or tablet. The ADT762 automatically analyzes errors, generates test reports, while storing results locally. The Additel 762 can support up to 1000 documented tasks which can be stored and recalled at any time to help save time and money.
    Dual-Mode Hart Communication
    HART pressure transmitters can be directly maintained and calibrated without any other equipment or tools. The ADT762 provides an automatic HART calibration mode as well as a manual mode. This dual-mode HART communication function not only provides an efficient and convenient interoperability mode for DUT, but also supports access to a fully HART capable calibrator.

     

    Pressure Specifications
    Pressure Range 0-10,000 psi (0-700 Bar)
    Range Selection Manual 3K psi, Manual 10K psi or Auto-range
    Accuracy 0-10,000 psi, 0.01%FS 0-10,000 psi, 0.02%FS
    0-3,000 psi, 0.01%FS 0-3,000 psi, 0.02%FS
    Maximum External Load Capacity Max: 80 ml @ 700 Bar, 50 ml reccomended
    Reservoir Max: 350 ml, push-on reservoir cap, built-in filter
    Control Stability [1] ≤ 0.005% FS
    Stability Duration > 5 min
    Pressure Modules Built-in one module with dual range
    External Control Pressure Module See the following “External Control Pressure Module Specification and Compatibility” table
    External Measurement Pressure Module All ADT161 pressure modules
    [1] Control Stability is based on the range of pressure control module

     

    Electrical Specifications
    Specification Range Resolution Accuracy Note
    Current Measure Auto-ranging ±25 or ±50 mA 0.1 μA 0.008 %RD + 1.0 μA Impedance < 10 Ω
    0.008 %RD + 2.0 μA
    Voltage Measure ±300 mV 1 μV 0.008 %RD + 6 μV Impedance > 1 GΩ
    Auto-ranging ±5, ±12 or ±30 V ±5 V: 20 μV 0.008 %RD + 100 μV Impedance > 1 MΩ
    ±12 V: 0.1 mV 0.008 %RD + 240 μV
    ±30 V: 0.1 mV 0.008 %RD + 600 μV
    Loop Power Source 24 V N/A ±1 V 50 mA (Max Loading)
    mA Source 0 to 2.5 mA or 2.5 to 25 mA 0-2.5 mA: 0.05μA, 0-25 mA: 0.5μA 0-2.5 mA: 0.008 %RD + 0.1 μA, 0-25 mA: 0.008 %RD + 1.0 μA 20 mA @ 1 kΩ
    Power Source 16 to 30 V 1 V ±1 V 70 mA (Max Loading)
    V Source 0 to 16 V 250 μV 0.008 %RD + 0.002 %FS
    Pressure Switch Mechanical Switch, Live Mechanical Switch, NPN Switch, PNP Switch N/A N/A Response time < 10 ms if the switch is powered. Voltage range: (3-30) V
    Temperature Compensation 18°C to 28°C
    Temperature Coefficient Outside of 18°C to 28°C: <±0.0005%RD+0.00005%FS/°C
    Misuse Protection Up to 30 V on any two sockets
    Pressure Switch Test Supported
    HART / Profibus PA Supported

     

    External Control Pressure Module Specification and Compatibility
    Specification Pressure Range Accuracy Pressure Type Media
    (psi) (bar)
    ADT161-01RD-GPXM for 0.01% rdg





    1000 70 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
    1500 100 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
    2000 140 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
    3000 200 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
    5000 350 0.01% rdg or 0.03% FS whichever is greater Gauge G,L
    10000 700 0.01% rdg or 0.03% FS whichever is greater Gauge G,L



    ADT161-02-GPXX for 0.02% FS


    1000 70 0.02 Gauge G,L
    1500 100 0.02 Gauge G,L
    2000 140 0.02 Gauge G,L
    3000 200 0.02 Gauge G,L
    5000 350 0.02 Gauge G,L
    10000 700 0.02 Gauge G,L
    [1] For 0.01% FS pressure modules, single or multiple measurement range calibration certificate per request.  For other specifications, please contact Additel for more details.

     

    General Specifications
    Specification Description
    User Interface Color touch screen and keypad operation
    Display 7” TFT touch screen 800 x 480 color
    Enclosure IP Rating IP31
    Power Dedicated lithium battery or power adapter
    Battery Rechargeable Li-Ion battery, typically 12 hours of operation, less than 5 hours recharge.
    Weight 28 lbs (12.8 kg) without media
    Size 11.81 x 8.66 x 7.56 in (300 x 220 x 192 mm)
    Communications Wi-Fi, LAN, Bluetooth, USB, Ethernet
    HART Communication Read, configure and calibrate HART devices – DD files updated periodically
    Data Storage > 8 GB
    Data Logging Up to 1,000,000 readings (data and time stamped)
    Task documentation Up to 1,000 tasks can be stored with data
    Automation Functions Switch test, auto step, leak test
    User Interface Localization English, German, French, Italian, Spanish, Portuguese, Chinese, Japanese, and Russian
    Pump life > 1,000,000 cycles
    Environmental Specifications Operating temperature: 32°F to 122°F( 0°C to 50°C)
    Storage temperature: -20°C to 60°C ( -4°F to 120°F)
    Humidity: <90%, non-condensing
    Certification ISO 17025 accredited certificate of calibration with NIST-traceable data
    Compliance CE
    Software Compatibility ACal, Additel Land and Additel Link for access via mobile application
    Warranty 1 year








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.