IMK331P Pressure Transmitter, stainless steel diaphragm


The pressure transmitter IMK 331P is suitable for measuring the pressure of viscous and pasty media, where a totally flush pressure port is required.

Datasheet
Mounting instructions
User Manual
Pressure

505: gauge, 506: absolute

Input

060: 0.6, 100: 1.0, 160: 1.6, 250: 2.5, 400: 4.0, 999: customer (consult)

Output

1: 4 … 20 mA / 2-wire, 2: 0 … 20 mA / 3-wire, 3: 0 … 10 V / 3-wire, E: intrinsic safety 4 … 20 mA / 2-wire, 1S: SIL2 4 … 20 mA / 2-wire, ES: SIL2 with intrinsic safety, 9: customer (consult)

Accuracy

5: 0.5% FSO, 9: customer (consult)

Electrical connection

1: male and female plug ISO 4400, 2: male plug Binder series 723 (5-pin), TA: cable outlet with PVC cable (IP67) (standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C); others on request), TR: cable outlet, with ventilation tube (IP68) (only for pₙ ≤ 100 bar possible), M: male plug M12x1 (4-pin) / metal, 850: compact field housing, 999: customer (consult)

Mechanical connection

Z00: G1/2" DIN 3852 with flush diaphragm, Z61: G1/2" DIN 3852 with radial o-ring and flush diaphragm, 999: customer (consult)

Diaphragm

1: stainless steel 1.4435 (316L), 9: customer (consult)

Seal

1: FKM, 7: FFKM (only for pₙ ≤ 100 bar possible), 9: customer (consult)

Filling fluid

1: silicone oil, 2: food compatible oil, 9: customer (consult)

Special version

000: standard, 200: with cooling element up to 300 °C (only for pₙ ≤ 160 bar possible), 999: customer (consult)









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    IMK331P Pressure Transmitter, stainless steel diaphragm

    The pressure transmitter IMK 331P is suitable for measuring the pressure of viscous and pasty media, where a totally flush pressure port is required.

    Datasheet
    Mounting instructions
    User Manual
    Pressure

    505: gauge, 506: absolute

    Input

    060: 0.6, 100: 1.0, 160: 1.6, 250: 2.5, 400: 4.0, 999: customer (consult)

    Output

    1: 4 … 20 mA / 2-wire, 2: 0 … 20 mA / 3-wire, 3: 0 … 10 V / 3-wire, E: intrinsic safety 4 … 20 mA / 2-wire, 1S: SIL2 4 … 20 mA / 2-wire, ES: SIL2 with intrinsic safety, 9: customer (consult)

    Accuracy

    5: 0.5% FSO, 9: customer (consult)

    Electrical connection

    1: male and female plug ISO 4400, 2: male plug Binder series 723 (5-pin), TA: cable outlet with PVC cable (IP67) (standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C); others on request), TR: cable outlet, with ventilation tube (IP68) (only for pₙ ≤ 100 bar possible), M: male plug M12x1 (4-pin) / metal, 850: compact field housing, 999: customer (consult)

    Mechanical connection

    Z00: G1/2" DIN 3852 with flush diaphragm, Z61: G1/2" DIN 3852 with radial o-ring and flush diaphragm, 999: customer (consult)

    Diaphragm

    1: stainless steel 1.4435 (316L), 9: customer (consult)

    Seal

    1: FKM, 7: FFKM (only for pₙ ≤ 100 bar possible), 9: customer (consult)

    Filling fluid

    1: silicone oil, 2: food compatible oil, 9: customer (consult)

    Special version

    000: standard, 200: with cooling element up to 300 °C (only for pₙ ≤ 160 bar possible), 999: customer (consult)









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.