HySense QT206 – CAN turbine volume flow sensor


  • Measuring principle volume flow
  • Viscosity range 1 … 10 mm²/s (cSt)
  • Medium temperature max. +120 °C
  • Environmental temperature -20 … +85 °C
  • Storage temperature -20 … +85 °C
  • Output signal CANopen
  • Supply voltage Ub 8.5 … 30 VDC
  • Electrical measuring connector 5 pole device connector, M12 x 1
  • Protection type (EN 60529 / IEC 529) IP 67 (screwed)
  • Tightening torque 10 Nm (± 2 Nm)
  • Calibration viscosity 30 mm²/s (cSt)
  • Material turbine casing high-grade steel, passivated (X12CrNiS18 8)
  • Material turbine wheel 1.4122 (for measuring range 1.0 … 10 l/min) 1.0718 (for all other measuring ranges)
  • Material sealings FKM
  • Material sensor casing 3.1645
  • Current consumption max. 50 mA @ 24 VDC
  • Interface CANopen (CIA-DS-301)
  • CAN standard 2.0A (opt. 2.0B)
  • Transmission rate 20 … 1,000 kBit/s
  • Measured frequency (Hz) bytes 0 … 3
  • Measured volume flow (l/min) bytes 4 … 7
  • Resolution three decimal places
  • Suitable measuring cable CAN cable

Not available anymore.

Datasheet
Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    HySense QT206 – CAN turbine volume flow sensor

    • Measuring principle volume flow
    • Viscosity range 1 … 10 mm²/s (cSt)
    • Medium temperature max. +120 °C
    • Environmental temperature -20 … +85 °C
    • Storage temperature -20 … +85 °C
    • Output signal CANopen
    • Supply voltage Ub 8.5 … 30 VDC
    • Electrical measuring connector 5 pole device connector, M12 x 1
    • Protection type (EN 60529 / IEC 529) IP 67 (screwed)
    • Tightening torque 10 Nm (± 2 Nm)
    • Calibration viscosity 30 mm²/s (cSt)
    • Material turbine casing high-grade steel, passivated (X12CrNiS18 8)
    • Material turbine wheel 1.4122 (for measuring range 1.0 … 10 l/min) 1.0718 (for all other measuring ranges)
    • Material sealings FKM
    • Material sensor casing 3.1645
    • Current consumption max. 50 mA @ 24 VDC
    • Interface CANopen (CIA-DS-301)
    • CAN standard 2.0A (opt. 2.0B)
    • Transmission rate 20 … 1,000 kBit/s
    • Measured frequency (Hz) bytes 0 … 3
    • Measured volume flow (l/min) bytes 4 … 7
    • Resolution three decimal places
    • Suitable measuring cable CAN cable