HySense QL110 – Turbine volume flow sensor with load valve
- Measuring principle volume flow
- Viscosity range 1 … 100 mm²/s (cSt)
- Medium temperature max. +120 °C
- Environmental temperature -20 … +85 °C (short-term up to +100 °C)
- Storage temperature -20 … +85 °C
- Output signal frequency (rectangular signal) / 4 … 20 mA
- Supply voltage Ub 12 … 24 VDC
- Error limit ± 2.5 % of current value
- Electrical measuring connector 5 pole device connector, M16 x 0.75
- Protection type (EN 60529 / IEC 529) IP 40
- Tightening torque (sensor) 10 Nm (± 2 Nm)
- Calibration viscosity 30 mm²/s (cSt)
- Material turbine casing Aluminium (AlZnMgCu 1,5)
- Material turbine wheel 1.0718
- Material sealings FKM
- Material sensor casing 3.1645 (QL 100) / 1.4301 (QL 110)
- Suitable measuring cable MK 01
Not available anymore.