IMP320 Precision Pressure Transmitter with Fast Response Time


designed for applications, in which an extremely fast and exact pressure measuring is required

Datasheet
User Manual

IDMP 320 stands for speed and precision.

With a response time of ≤ 0.5 msec and a sampling rate of 10 kHz, the pressure transmitter was designed for applications, in which an extremely fast and exact pressure measuring is required. Pressure curves, peaks and hits can be monitored and evaluated exactly.

The signal processing of the sensor signal is done by newly developed digital electronics, which detect the signal with a sampling rate of 10 kHz. Sensor-specific deviations such as non-linearity, hysteresis and temperature errors are compensated actively.

Features

  • nominal pressure: 0 … 100 mbar up to 0 … 600 bar
  • accuracy: 0,1 % FSO
  • internal sample rate 10 kHz
  • excellent thermal behavior
  • excellent long term stability
  • extremely short response times ≤ 0.5 ms

Optional Features

customer specific versions

Pressure

1C: gauge , 1D: absolute ( from 0.4 bar)

Input

1000: 0.10 bar (absolute pressure possible from 0.4 bar) , 1600: 0.16 bar (absolute pressure possible from 0.4 bar) , 2500: 0.25 bar (absolute pressure possible from 0.4 bar) , 4000: 0.40 bar , 6000: 0.60 bar , 1010: 1.0 bar , 1610: 1.6 bar , 2510: 2.5 bar , 4010: 4.0 bar , 6010: 6.0 bar , 1020: 10 bar , 1620: 16 bar , 2520: 25 bar , 4020: 40 bar , 6020: 60 bar , 1030: 100 bar , 2030: 160 bar , 3030: 250 bar , 4030: 400 bar , 6030: 600 bar , X102: -1 … 0 bar , 9999: customer 

Output

3A: 0.1 … 10 V / 3 wire , 7: 4 … 20 mA / 3 wire , 9: customer 

Accuracy

1: for pN ≥ 0.25 bar: 0.10 % FSO , 2: for pN < 0.25 bar: 0.25 % FSO , 9: customer 

Electrical connection

100: male and female plug ISO 4400 , 200: male plug Binder series 723 (5-pin) , TA0: cable outlet with PVC cable (IP67) (standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C); others on request), TR0: cable with ventilation tube (IP68) (PVC cable, cable with ventilation tube available in different types and lengths) , M10: male plug M12x1 (4-pin) / metal , 850: compact field housing , 999: customer 

Mechanical connection

100: G1/2" DIN 3852 , 200: G1/2" EN 837 , 300: G1/4" DIN 3852 , 400: G1/4" EN 837 , F00: G1/2" DIN 3852 open pressure port (only for pN ≤ 40 bar), N00: 1/2" NPT , N40: 1/4" NPT , 999: customer 

Seals

1: FKM , 3: EPDM , 9: customer 

Special version

000: standard , 999: customer 





Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    IMP320 Precision Pressure Transmitter with Fast Response Time

    designed for applications, in which an extremely fast and exact pressure measuring is required

    Datasheet
    User Manual

    IDMP 320 stands for speed and precision.

    With a response time of ≤ 0.5 msec and a sampling rate of 10 kHz, the pressure transmitter was designed for applications, in which an extremely fast and exact pressure measuring is required. Pressure curves, peaks and hits can be monitored and evaluated exactly.

    The signal processing of the sensor signal is done by newly developed digital electronics, which detect the signal with a sampling rate of 10 kHz. Sensor-specific deviations such as non-linearity, hysteresis and temperature errors are compensated actively.

    Features

    • nominal pressure: 0 … 100 mbar up to 0 … 600 bar
    • accuracy: 0,1 % FSO
    • internal sample rate 10 kHz
    • excellent thermal behavior
    • excellent long term stability
    • extremely short response times ≤ 0.5 ms

    Optional Features

    customer specific versions

    Pressure

    1C: gauge , 1D: absolute ( from 0.4 bar)

    Input

    1000: 0.10 bar (absolute pressure possible from 0.4 bar) , 1600: 0.16 bar (absolute pressure possible from 0.4 bar) , 2500: 0.25 bar (absolute pressure possible from 0.4 bar) , 4000: 0.40 bar , 6000: 0.60 bar , 1010: 1.0 bar , 1610: 1.6 bar , 2510: 2.5 bar , 4010: 4.0 bar , 6010: 6.0 bar , 1020: 10 bar , 1620: 16 bar , 2520: 25 bar , 4020: 40 bar , 6020: 60 bar , 1030: 100 bar , 2030: 160 bar , 3030: 250 bar , 4030: 400 bar , 6030: 600 bar , X102: -1 … 0 bar , 9999: customer 

    Output

    3A: 0.1 … 10 V / 3 wire , 7: 4 … 20 mA / 3 wire , 9: customer 

    Accuracy

    1: for pN ≥ 0.25 bar: 0.10 % FSO , 2: for pN < 0.25 bar: 0.25 % FSO , 9: customer 

    Electrical connection

    100: male and female plug ISO 4400 , 200: male plug Binder series 723 (5-pin) , TA0: cable outlet with PVC cable (IP67) (standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C); others on request), TR0: cable with ventilation tube (IP68) (PVC cable, cable with ventilation tube available in different types and lengths) , M10: male plug M12x1 (4-pin) / metal , 850: compact field housing , 999: customer 

    Mechanical connection

    100: G1/2" DIN 3852 , 200: G1/2" EN 837 , 300: G1/4" DIN 3852 , 400: G1/4" EN 837 , F00: G1/2" DIN 3852 open pressure port (only for pN ≤ 40 bar), N00: 1/2" NPT , N40: 1/4" NPT , 999: customer 

    Seals

    1: FKM , 3: EPDM , 9: customer 

    Special version

    000: standard , 999: customer 





    Technical advice: 03303 / 50 40 66