- Simple mounting
- Compact and heavy-duty version
- High reproducibility
- Integrated switching output
- With automatic resetting
![]() |
![]() |
- 3 digit LED display
- Recording min./max. temerature
- Measuring ranges from -20…200°C
- Contact output DC PNP, max. 200 mA
- Analog output: 4…20 mA, 3-wires 0…10 V, 3-wires 0...20 mA, 3-wires
![]() |
- Case aluminium, epoxy resin coated
- Ingress protection IP 65, NEMA 4
- Ambient temperature -40 ... +85 °C
- 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A / AC 220 V
- Capillary up to 10 m
![]() |
![]() |
- Case aluminium, epoxy resin coated
- Ingress protection IP 65, NEMA 4
- Ambient temperature -40 ... +85 °C
- 1 switch point, SPDT or DPDT with a high contact rating of up to 15 A/AC 220 V
- Capillary up to 10 m
![]() |
![]() |
- Easily-readable, robust display
- Intuitive and fast setup
- Easy and flexible mounting configurations
![]() |
- No power supply needed for switching of electrical loads
- Setting ranges from -30 ... +70°C up to 0 ... 600 °C
- Robust switch enclosure from aluminium alloy, IP 66, NEMA 4X
- 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
- Remote mounting with capillary ≤ 10 m
![]() |
![]() |
- Electropolished case
- Ingress protection IP 65, NEMA 4
- Ambient temperature -40 ... +85 °C
- 1 or 2 independent switch points, high contact rating up to 15 A / AC 220 V
- Directly connected or via capillary (up to 10 m capillary)
![]() |
![]() |
- Case from AISI 316 (1.4401)
- Ingress protection IP 66, NEMA 4
- Ambient temperature -40 ... +85 °C
- 1 switch point, SPDT, up to 5 A/AC 220 V
- Directly connected or via capillary (up to 10 m capillary
![]() |
![]() |
- No power supply needed for switching of electrical loads
- Setting ranges from -15 ... +20 °C to 180 ... 250 °C
- Repeatability of the set point ≤ 1% span
- 1 set point, SPDT, high switching power up to AC 250 V, 5 A
- Direct mounting or remote mounting with capillary ≤ 10 m
![]() |
![]() |
Control input signal | 0..10V= |
Temp. setpoint range | 1 ... 10 oC |
Output Signal | 0..10V: Input/Temp. |
Ambient temperature | 15 ... 15 oC |
Switch function/capacity | SPDT 250 Vac Microswitch / 8A |
Reset function | reset inside |
Thermostat application | frost protection thermostat, 2-phases |
Mounting place | air duct |
IP class | IP40 |
Power supply | 24 Vac | 7 VA |
Temperature element | capillary |
Setpoint device | inside |
Additional description | The 0-10V output signal is the maximum of the input signal and the temperature value (10-0 degrees C = 0-10V) |
![]() |
Housing material | Polycarbonate and ABS |
Ambient temperature | -20 ... 55 oC |
Switch function/capacity | SPDT 24..250 Vac, 15(8)A |
Thermostat application | frost protection thermostat |
Mounting place | air duct |
Setpoint device | screw |
Temp. setpoint range | -8 ... 8 oC |
Differential fixed | 2 K |
IP class | IP65 |
![]() |
Electrical connection | M20x1,5 |
IP class | IP54 |
Housing material | PA, ABS, PMMA |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | max: 230 Vac, 12 (2,5) A min: 24 Vac/dc, 100 mA |
Capillary tube length | 2 m |
Certificates | CE, UL, PED, DIN EN 14597 |
Thermostat application | strap-on thermostat |
Reset function | automatic reset |
Setpoint device | screw |
Mounting place | strap on pipe |
Differential fixed | 10 K |
![]() |
Housing material | glass fibre reinforced ABS |
Ambient temperature | -20 ... 70 oC |
Thermostat application | room thermostat, industrial |
Mounting place | internal wall |
Setpoint device | knob |
![]() |
IP class | IP54 |
Housing material | Aluminium diecasting with plastic cover |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | SPST 230 Vac, 10 A |
Immersion depth | 150 mm |
Certificates | TUEV-approval STB895 |
Thermostat application | immersion tube thermostat |
Reset function | reset button |
Setpoint device | inside |
Temp. setpoint range | 60 ... 130 oC |
Mounting place | in pipe |
Immersion well material | red brass, nickel plated |
Immersion well thread | R1/2" |
Max. perm. temp. at sensor | 150 oC |
![]() |
IP class | IP54 |
Housing material | Aluminium diecasting with plastic cover |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A |
Immersion depth | 150 mm |
Certificates | TUEV-approval TR/STB 900 |
Thermostat application | immersion tube therm. + controller |
Reset function | reset button |
Setpoint device | inside+outside |
Temp. setpoint range | 30/30 ... 110/110 oC |
Mounting place | in pipe |
Immersion well material | red brass, nickel plated |
Immersion well thread | R1/2" |
Max. perm. temp. at sensor | 130 oC |
Additional description | Safety control switching differential approx. 4% of setpoint value. Shut-off temperature: 30..110 oC adjustable. |
![]() |
IP class | IP54 |
Housing material | Aluminium diecasting with plastic cover |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | SPDT 230 Vac, 10 A |
Certificates | TUEV-approval STW(STB)894 S |
Thermostat application | immersion tube thermostat |
Reset function | automatic reset |
Setpoint device | inside |
Temp. setpoint range | 20 ... 150 oC |
Mounting place | in pipe |
Immersion depth | 150 mm |
Immersion well material | red brass, nickel plated |
Immersion well thread | R1/2" |
Max. perm. temp. at sensor | 175 oC |
Additional description | Fixed switching differential approx. 4% of setpoint value. |
![]() |
IP class | IP54 |
Housing material | Aluminium diecasting with plastic cover |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A |
Immersion depth | 150 mm |
Certificates | TUEV-approval TW/STB 904 |
Thermostat application | immersion tube therm. + monitor |
Reset function | reset button |
Setpoint device | 2x inside |
Temp. setpoint range | 30/30 ... 110/110 oC |
Mounting place | in pipe |
Immersion well material | red brass, nickel plated |
Immersion well thread | R1/2" |
Max. perm. temp. at sensor | 130 oC |
Additional description | Safety control switching differential approx. 3..4% of setpoint value. Shut-off temperature: 30..110 oC adjustable. |
![]() |
IP class | IP54 |
Housing material | Aluminium diecasting with plastic cover |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | SPDT 230 Vac, 10 A |
Immersion depth | 150 mm |
Certificates | TUEV-approval TW 89 207 |
Thermostat application | immersion tube thermostat |
Reset function | automatic reset |
Setpoint device | inside |
Temp. setpoint range | 20 ... 150 oC |
Mounting place | in pipe |
Immersion well material | red brass, nickel plated |
Immersion well thread | R1/2" |
Max. perm. temp. at sensor | 175 oC |
![]() |
IP class | IP54 |
Housing material | Aluminium diecasting with plastic cover |
Ambient temperature | 0 ... 80 oC |
Switch function/capacity | safety control switch SPDT 230 Vac, 10 A; shut-off temperature switch SPST 230 Vac, 10 A |
Immersion depth | 150 mm |
Certificates | TUEV-approval TR/STB 900 |
Thermostat application | immersion tube therm. + controller |
Reset function | reset button |
Setpoint device | inside+outside |
Temp. setpoint range | 30/30 ... 110/110 oC |
Mounting place | in pipe |
Immersion well material | red brass, nickel plated |
Immersion well thread | R1/2" |
Max. perm. temp. at sensor | 130 oC |
Additional description | Safety control switching differential approx. 4% of setpoint value. Shut-off temperature: 30..110 oC adjustable. |
![]() |

Temperature Switches & Thermostats – safe switching, reliable control
Temperature switches and thermostats monitor thresholds and switch loads or signals—from building/HVAC and machine & plant engineering to process & food applications. Available as mechanical bimetal/capillary thermostats or electronic temperature switches with relay, solid-state or transistor outputs, optionally with analog output, IO-Link, or Modbus.
Features: adjustable setpoint(s), defined hysteresis, IP protection up to IP69K, media-contacting sensors (immersion sleeves/thermowells) or surface/pipe mounting. ICS Schneider Messtechnik supports selection, design, parameterization, calibration and integration into PLC/SCADA/IIoT.
FAQ on Temperature Switches & Thermostats
Answers on types, hysteresis, accuracy, mounting, IP/Ex, outputs, loads and digitalization.
What are temperature switches & thermostats particularly suitable for?
For safe on/off control when limits are exceeded or undershot (e.g., fan, heating, cooling, alarm) without complex control loops.
What’s the difference between a thermostat and an electronic temperature switch?
Thermostat: mechanical/capillary, mains-independent, direct switching. Electronic switch: sensor + electronics, more precise setpoints, display/diagnostics, digital interfaces.
What types are available?
Type | Characteristics | Use |
---|---|---|
Bimetal | simple, robust, fixed hysteresis | HVAC, machinery |
Capillary | remote sensor, high switching capacity | ovens, refrigeration |
Electronic | accurate, one/two setpoints, display | process, IIoT |
Which outputs are available?
Output | Advantages | Notes |
---|---|---|
Relay (NO/NC/changeover) | galvanic isolation, AC/DC load | contact wear |
SSR/solid-state | fast, wear-free | leakage current, cooling |
PNP/NPN | direct to PLC | current/voltage limits |
Analog (4–20 mA/0–10 V) | process value + limit | scaling/EMC |
IO-Link/Modbus | data, parameterization, diagnostics | master/addressing |
What is hysteresis and why is it important?
Hysteresis is the difference between switch-on and switch-off points. It prevents chattering and protects actuators. Often fixed in mechanical devices; freely adjustable in electronic ones.
How accurate is the switching?
Mechanical typically ±1…3 K, electronic typically ±0.2…0.5 K (depends on sensor, installation and ambient conditions).
What about repeatability/drift?
Mechanics: higher drift over lifetime. Electronics: very good repeatability, drift can be compensated via calibration.
What switching loads are possible?
Relays depending on type e.g. 250 VAC up to several amperes; solid-state for frequent switching. Protect inductive loads with snubbers.
How do I select the temperature range?
Choose a range so that setpoint + hysteresis stay within permitted sensor/enclosure temperatures; include safety margin for ambient influences.
What IP ratings are available?
Depending on design IP54–IP69K. For wash-down use hygienic sealing and cable glands with strain relief.
How is mounting done (pipe/medium/air)?
- Pipe/surface: pipe clamp + thermal paste
- Immersion sleeve: for pressurized media (316L, etc.)
- Air/duct: ensure airflow, use shielding
Which immersion sleeve/thermowell is suitable?
Consider material (e.g., 316L), pressure/temperature, flow, and length (short time constant); enables replacement without draining the medium.
How do I set the switching point?
Mechanical: via scale/screw. Electronic: via keys/display, PC/IO-Link. Document parameters for QA/traceability.
Which sensing principles do electronic switches use?
Typically RTD (Pt100/Pt1000) or thermocouple—internally linearized; choose based on range, accuracy, response time.
How fast do thermostats/switches respond?
Mechanical: depends on installation/thermowell (seconds). Electronic: short response times, configurable filters/averaging.
How do I ensure EMC-compliant installation?
Shielded, twisted cables, proper grounding, separation of power/signal lines, optionally line filters/ferrites. Ensure equipotential bonding.
Use in hazardous (Ex) areas (ATEX/IECEx)?
Possible with Ex i or Ex d versions. Observe zone, temperature class, marking and suitable barriers/connectors.
SIL/functional safety—possible?
Some electronic devices are available with SIL data. Consider proof-test intervals, diagnostic coverage and NE43/NE107.
How do I test/calibrate switching points?
Using a temperature calibrator/bath and reference sensor. Verify setpoint on rising/falling temperature, document hysteresis; intervals typically annually.
How do I integrate the devices into PLC/IIoT?
Binary inputs (relay/PNP/NPN) for alarms; analog value + limit via 4–20 mA/0–10 V; IO-Link/Modbus for parameters/diagnostics → edge/gateway → MQTT/HTTPS.
Typical failure modes and remedies?
- Contact wear → size relay correctly, RC/varistor protection
- Chattering → increase hysteresis, decouple the control path
- Offset/drift → calibrate, check installation
- Interference → EMC measures, optimize cable routing
Do you support selection & commissioning?
Yes. We size sensor/thermowell, define setpoints/hysteresis, select outputs, handle parameterization and supply calibration certificates.