Differential Pressure Transmitter IPD41


  • Measuring sensor with stainless steel membranes made of 1.4404
  • Smallest measuring range: 0…50 mbar
  • Largest measuring range: 0…25 bar
  • Negative pressure measuring range: up to -25 bar
  • Accuracy ≤ 0,2%
  • One-sided overload capability up to 40 bar
  • Rugged industrial design
  • Analog output: 4…20 mA, 2-wires
                              0…10 V, 3-wires
Datasheet
User Manual

The  IPD40/41  differential pressure transmitters are characterized by a robust design and a significantly high overload capability. The stainless steel membrane and process connection are laser-welded, resulting in high media resistance and long-term stability. Each measuring range is temperature compensated,  which  in  combination with the piezoresistive measuring principle results in a very accurate measurement even at lowest pressures. Various electrical connection options allow easy integration and are protected against dust and water with IP 67.

 

  • Gaseous media
  • Liquid media
  • Hygiene applications
  • Viscous and pasty media
  • Aggressive media
  • Pressure superimposed level measurement

 

Measuring ranges Smallest measuring range: 0…50 mbar
Largest measuring range: 0…25 bar
Negative pressure measuring range: up to -25 bar
Analog output 4…20 mA, 2-wires
0…10 V, 3-wires
Power supply 20 mA output: 9…30 V DC
10 V output: 15…30 V DC
Accuracy ≤ ± 0,2 % FS @ 25 °C
Long term stability ≤ ± 0,1 % FS / Year
Static pressure influence ≤ ± 0,1 % FS/ 10 bar
Hysteresis ≤ ± 0,05 % FS
Response time 200 ms – others on request
Swich-on time < 1 s
Temperature coefficient Zero: ≤ ± 0,02 % FS / Kelvin
Span: ≤ ± 0,02 % FS / Kelvin
Medium temperature -25…120 °C
Surrounding temperature -25…85 °C
Storage temperature -40…85 °C
Short-circuit resistance Permanent
Reverse polarity protection Protection against reverse polarity, but no function
Electromagnetic compatibility Interference emissions and immunity acc. to EN 61326
Wetted materials Process connection: Stainless steel 1.4404
Sensor: Stainless steel 1.4404 with silicone oil filling
Protection type IP 67
Weight Approx. 650 g
Output signal

1: 0…10 V / 3-wire, 4: 4…20 mA / 2-wire

Measuring range

PB0: 0…50 mbar / 0…5 kPa, PA9: 0…60 mbar / 0…6 kPa, PY1: 0…75 mbar / 0…7,5 kPa, P00: 0…100 mbar / 0…10 kPa, P01: 0…160 mbar / 0…16 kPa, PB1: 0…200 mbar / 0…20 kPa, P02: 0…250 mbar / 0…25 kPa, PX5: 0…300 mbar / 0…30 kPa, PY2: 0…370 mbar / 0…37 kPa, P03: 0…400 mbar / 0…40 kPa, PB7: 0…500 mbar / 0…50 kPa, P04: 0…600 mbar / 0…60 kPa, P05: 0…1 bar / 0…100 kPa, P06: 0…1,6 bar / 0…160 kPa, PB3: 0…2 bar / 0…200 kPa, P07: 0…2,5 bar / 0…250 kPa, PX3: 0…3 bar / 0…300 kPa, P08: 0…4 bar / 0…400 kPa, PF1: 0…5 bar / 0…500 kPa, P09: 0…6 bar / 0…600 kPa, P10: 0…10 bar / 0…1 MPa, P11: 0…16 bar / 0…1,6 MPa, PB5: 0…20 bar / 0…2 MPa, P12: 0…25 bar / 0…2,5 MPa, BE6: -25…25 mbar / -2,5…2,5 kPa, BB0: -50…50 mbar / -5…5 kPa, BA9: -60…60 mbar / -6…6 kPa, BY1: -75…75 mbar / -7,5…7,5 kPa, B00: -100…100 mbar / -10…10 kPa, B01: -160…160 mbar / -16…16 kPa, BB1: -200…200 mbar / -20…20 kPa, B02: -250…250 mbar / -25…25 kPa, BX5: -300…300 mbar / -30…30 kPa, BY2: -370…370 mbar / -37…37 kPa, B03: -400…400 mbar / -40…40 kPa, BB7: -500…500 mbar / -50…50 kPa, B04: -600…600 mbar / -60…60 kPa, B05: -1…1 bar / -100…100 kPa, B06: -1,6…1,6 bar / -160…160 kPa, BB3: -2…2 bar / -200…200 kPa, B07: -2,5…2,5 bar / -250…250 kPa, BX3: -3…3 bar / -300…300 kPa, B08: -4…4 bar / -400…400 kPa, BF1: -5…5 bar / -500…500 kPa, B09: -6…6 bar / -600…600 kPa, B10: -10…10 bar / -1…1 MPa, B11: -16…16 bar / -1,6…1,6 MPa, BB5: -20…20 bar / -2…2 MPa, B12: -25…25 bar / -2,5…2,5 MPa, B99: special measuring range

Process connection and material

0: light end flanges Pmax. 100 bar – G 1/4 female, ISO 228-1, 1.4404
R: light end flanges Pmax. 100 bar – 1/4-18 NPT, 1.4404
S: heavy end flanges Pmax. 250 bar – 1/4-18 NPT, 1.4404
M: heavy end flanges Pmax. 160 bar – M10, 1.4404

Process seal

0: None, 1: FPM (Viton), standard, 3: EPDM

Connection

1: Connector EN 175301-803A
A: Connector M12x1
F: Quickon connector
H: 10 m cable
0: 5 m cable
6: 2 m cable
9: Special version

Installation position

S: Pressure ports lateral, L: Low port on top, H: High port on top

Options

0: none









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Differential Pressure Transmitter IPD41

    • Measuring sensor with stainless steel membranes made of 1.4404
    • Smallest measuring range: 0…50 mbar
    • Largest measuring range: 0…25 bar
    • Negative pressure measuring range: up to -25 bar
    • Accuracy ≤ 0,2%
    • One-sided overload capability up to 40 bar
    • Rugged industrial design
    • Analog output: 4…20 mA, 2-wires
                                0…10 V, 3-wires
    Datasheet
    User Manual

    The  IPD40/41  differential pressure transmitters are characterized by a robust design and a significantly high overload capability. The stainless steel membrane and process connection are laser-welded, resulting in high media resistance and long-term stability. Each measuring range is temperature compensated,  which  in  combination with the piezoresistive measuring principle results in a very accurate measurement even at lowest pressures. Various electrical connection options allow easy integration and are protected against dust and water with IP 67.

     

    • Gaseous media
    • Liquid media
    • Hygiene applications
    • Viscous and pasty media
    • Aggressive media
    • Pressure superimposed level measurement

     

    Measuring ranges Smallest measuring range: 0…50 mbar
    Largest measuring range: 0…25 bar
    Negative pressure measuring range: up to -25 bar
    Analog output 4…20 mA, 2-wires
    0…10 V, 3-wires
    Power supply 20 mA output: 9…30 V DC
    10 V output: 15…30 V DC
    Accuracy ≤ ± 0,2 % FS @ 25 °C
    Long term stability ≤ ± 0,1 % FS / Year
    Static pressure influence ≤ ± 0,1 % FS/ 10 bar
    Hysteresis ≤ ± 0,05 % FS
    Response time 200 ms – others on request
    Swich-on time < 1 s
    Temperature coefficient Zero: ≤ ± 0,02 % FS / Kelvin
    Span: ≤ ± 0,02 % FS / Kelvin
    Medium temperature -25…120 °C
    Surrounding temperature -25…85 °C
    Storage temperature -40…85 °C
    Short-circuit resistance Permanent
    Reverse polarity protection Protection against reverse polarity, but no function
    Electromagnetic compatibility Interference emissions and immunity acc. to EN 61326
    Wetted materials Process connection: Stainless steel 1.4404
    Sensor: Stainless steel 1.4404 with silicone oil filling
    Protection type IP 67
    Weight Approx. 650 g
    Output signal

    1: 0…10 V / 3-wire, 4: 4…20 mA / 2-wire

    Measuring range

    PB0: 0…50 mbar / 0…5 kPa, PA9: 0…60 mbar / 0…6 kPa, PY1: 0…75 mbar / 0…7,5 kPa, P00: 0…100 mbar / 0…10 kPa, P01: 0…160 mbar / 0…16 kPa, PB1: 0…200 mbar / 0…20 kPa, P02: 0…250 mbar / 0…25 kPa, PX5: 0…300 mbar / 0…30 kPa, PY2: 0…370 mbar / 0…37 kPa, P03: 0…400 mbar / 0…40 kPa, PB7: 0…500 mbar / 0…50 kPa, P04: 0…600 mbar / 0…60 kPa, P05: 0…1 bar / 0…100 kPa, P06: 0…1,6 bar / 0…160 kPa, PB3: 0…2 bar / 0…200 kPa, P07: 0…2,5 bar / 0…250 kPa, PX3: 0…3 bar / 0…300 kPa, P08: 0…4 bar / 0…400 kPa, PF1: 0…5 bar / 0…500 kPa, P09: 0…6 bar / 0…600 kPa, P10: 0…10 bar / 0…1 MPa, P11: 0…16 bar / 0…1,6 MPa, PB5: 0…20 bar / 0…2 MPa, P12: 0…25 bar / 0…2,5 MPa, BE6: -25…25 mbar / -2,5…2,5 kPa, BB0: -50…50 mbar / -5…5 kPa, BA9: -60…60 mbar / -6…6 kPa, BY1: -75…75 mbar / -7,5…7,5 kPa, B00: -100…100 mbar / -10…10 kPa, B01: -160…160 mbar / -16…16 kPa, BB1: -200…200 mbar / -20…20 kPa, B02: -250…250 mbar / -25…25 kPa, BX5: -300…300 mbar / -30…30 kPa, BY2: -370…370 mbar / -37…37 kPa, B03: -400…400 mbar / -40…40 kPa, BB7: -500…500 mbar / -50…50 kPa, B04: -600…600 mbar / -60…60 kPa, B05: -1…1 bar / -100…100 kPa, B06: -1,6…1,6 bar / -160…160 kPa, BB3: -2…2 bar / -200…200 kPa, B07: -2,5…2,5 bar / -250…250 kPa, BX3: -3…3 bar / -300…300 kPa, B08: -4…4 bar / -400…400 kPa, BF1: -5…5 bar / -500…500 kPa, B09: -6…6 bar / -600…600 kPa, B10: -10…10 bar / -1…1 MPa, B11: -16…16 bar / -1,6…1,6 MPa, BB5: -20…20 bar / -2…2 MPa, B12: -25…25 bar / -2,5…2,5 MPa, B99: special measuring range

    Process connection and material

    0: light end flanges Pmax. 100 bar – G 1/4 female, ISO 228-1, 1.4404
    R: light end flanges Pmax. 100 bar – 1/4-18 NPT, 1.4404
    S: heavy end flanges Pmax. 250 bar – 1/4-18 NPT, 1.4404
    M: heavy end flanges Pmax. 160 bar – M10, 1.4404

    Process seal

    0: None, 1: FPM (Viton), standard, 3: EPDM

    Connection

    1: Connector EN 175301-803A
    A: Connector M12x1
    F: Quickon connector
    H: 10 m cable
    0: 5 m cable
    6: 2 m cable
    9: Special version

    Installation position

    S: Pressure ports lateral, L: Low port on top, H: High port on top

    Options

    0: none









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.