Series 6 – Ultramat/Oxymat 6


  • Corrosion-resistant materials in the gas channel (optional): Measurement possible in highly corrosive measuring gases
  • Cleanable measuring chambers: Cost savings thanks to further use in case of contamination
  • Open interface architecture (RS 485, RS 232, PROFIBUS)
  • SIPROM GA network for maintenance and service information (optional)
Datasheet

Best combination for IR-active components and oxygen

The ULTRAMAT/OXYMAT 6 combines the features of the ULTRAMAT 6 and the OXYMAT 6 in one 19″ analyzer.  Most frequently used for demanding applications, the ULTRAMAT/OXYMAT 6 must meet high standards with regard to reliability and measurement quality. This is guaranteed by state-of-the-art electronics, ease of operation, and a physical element that is adapted to the measurement task.

Are you interested in multi-component measurements in one device? Take a look at our modular device system SIPROCESS GA700.

Increasing Selectivity

Up to two infrared-active components and oxygen can be measured in one device. The use of optical couplers and optical filters in the IR physics leads to an increase in selectivity and in many cases also enables the measurement in complex gas mixtures. This ensures measurements of low concentrations as well as low detection limits. The OXYMAT physics is based on measuring oxygen using the paramagnetic alternating pressure method. This ensures absolute linearity and allows parameterization of smallest measuring ranges from 0 to 0.5% (detection limit 50 ppm) up to 0 to 100% in one device.

Technical specifications

Max. number of components
2 IR + O2
Components
O2 & IR-active comp.
Minimal measuring range

0-0.5% O2 and IR component-specific:
0–5/0–100 ppm

Housing
19″ rack








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Series 6 – Ultramat/Oxymat 6

    • Corrosion-resistant materials in the gas channel (optional): Measurement possible in highly corrosive measuring gases
    • Cleanable measuring chambers: Cost savings thanks to further use in case of contamination
    • Open interface architecture (RS 485, RS 232, PROFIBUS)
    • SIPROM GA network for maintenance and service information (optional)
    Datasheet

    Best combination for IR-active components and oxygen

    The ULTRAMAT/OXYMAT 6 combines the features of the ULTRAMAT 6 and the OXYMAT 6 in one 19″ analyzer.  Most frequently used for demanding applications, the ULTRAMAT/OXYMAT 6 must meet high standards with regard to reliability and measurement quality. This is guaranteed by state-of-the-art electronics, ease of operation, and a physical element that is adapted to the measurement task.

    Are you interested in multi-component measurements in one device? Take a look at our modular device system SIPROCESS GA700.

    Increasing Selectivity

    Up to two infrared-active components and oxygen can be measured in one device. The use of optical couplers and optical filters in the IR physics leads to an increase in selectivity and in many cases also enables the measurement in complex gas mixtures. This ensures measurements of low concentrations as well as low detection limits. The OXYMAT physics is based on measuring oxygen using the paramagnetic alternating pressure method. This ensures absolute linearity and allows parameterization of smallest measuring ranges from 0 to 0.5% (detection limit 50 ppm) up to 0 to 100% in one device.

    Technical specifications

    Max. number of components
    2 IR + O2
    Components
    O2 & IR-active comp.
    Minimal measuring range

    0-0.5% O2 and IR component-specific:
    0–5/0–100 ppm

    Housing
    19″ rack








    Technical advice: 03303 / 50 40 66

    Technical advice for this product