SIEMENS Transmitter MAG5000 / MAG6000


The MAG 5000 and 6000 are transmitters engineered for high performance, easy installation, commissioning and maintenance. The transmitters evaluate the signals from the SITRANS F M sensors type MAG 1100, MAG 1100 F, MAG 3100, MAG 3100 P and MAG 5100 W.

Transmitter types:

  • MAG 5000: Max. measuring error ± 0.4 % ± 1 mm/s (incl. sensor)
  • MAG 6000: Max. measuring error ± 0.2 % ± 1 mm/s (incl. sensor, see also sensor specifications) and with additional features such as: “plug & play” add-on bus modules; integrated batch functions.
Datasheet
User Manual

Benefits

  • Superior signal resolution for optimum turn down ratio
  • Digital signal processing with many possibilities
  • Automatic reading of SENSORPROM data for easy commissioning
  • User configurable operation menu with password protection
  • 3 lines, 20 characters display in 11 languages
  • Flow rate in various units
  • Totalizer for forward, reverse and net flow as well as additional information available
  • Multiple functional outputs for process control, minimum configuration with analogue, pulse/frequency and relay output (status, flow direction, limits)
  • Comprehensive self-diagnostic for error indication and error logging (see SITRANS F M diagnostics)
  • Batch control (MAG 6000 only)
  • Custody transfer approval: MI-001 for cold water, PTB K 7.2 and OE12/C 040 for chilled water
  • MAG 6000 with add-on bus modules for HART, FOUNDATION Fieldbus H1, DeviceNet, Modbus RTU/RS485, PROFIBUS PA and DP

Application

The SITRANS F M flowmeters are suitable for measuring the flow of almost all electrically conductive liquids, pastes and slurries. The main applications can be found in:

  • Water and waste water
  • Chemical and pharmaceutical industries
  • Food and beverage industries
  • Power generation and utility

Design

The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19″ version as a 19″ insert as a base to be used in:

  • 19″ rack systems
  • Front panel mounting IP65/NEMA 2
  • Panel mounting IP20/NEMA 1
  • Wall mounting IP66/NEMA 4X

Several options on 19″ versions are available such as:

  • Transmitters mounted in safe area for Ex ATEX approved flow sensors (incl. barriers)
  • Transmitters with electrode cleaning unit on request

Function

The MAG 5000/6000 are transmitters with a built-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current.

Further information on connection, mode of operation and installation can be found in the data sheets for the sensors.

Displays and controls

Operation of the transmitter can be carried out using:

  • Control and display unit
  • HART communicator
  • PC/laptop and SIMATIC PDM software via HART communication
  • PC/laptop and SIMATIC PDM software using PROFIBUS or Modbus communication

Technical specifications

Mode of operation and design

Measuring principle

Electromagnetic with pulsed constant field

Empty pipe

Detection of empty pipe (special cable required in remote mounted installation)

Excitation frequency

Depend on sensor size

Electrode input impedance

> 1 x 1014 Ω

Input

Digital input

11 … 30 V DC, Ri = 4. 4 KΩ

  • Activation time

50 ms

  • Current

I11 V DC = 2.5 mA, I30 V DC = 7 mA

Output

Current output

  • Signal range

0 … 20 mA or 4 … 20 mA

  • Load

< 800 Ω

  • Time constant

0.1 … 30 s, adjustable

Digital output

  • Frequency

0 … 10 kHz, 50 % duty cycle (uni/bidirectional)

  • Pulse (active)

24 V DC, 30 mA, 1 kΩ ≤ Ri ≤ 10 kΩ, short-circuit-protected (power supplied from flowmeter)

  • Pulse (passive)

3 … 30 V DC, max. 110 mA, 200 Ω ≤ Ri ≤ 10 kΩ powered from connected equipment)

  • Time constant

0.1 … 30 s, adjustable

Relay output

  • Time constant

Changeover relay, same as current output

  • Load

42 V AC/2 A, 24 V DC/1 A

Low flow cut off

0 … 9.9 % of maximum flow

Galvanic isolation

All inputs and outputs are galvanically isolated

Max. measuring error (incl. sensor and zero point) (for detailed accuracy specifications see “System information”)

  • MAG 5000

± 0.4 % ± 1 mm/s

  • MAG 6000

± 0.2 % ± 1 mm/s

Rated operation conditions

Ambient temperature

  • Operation
  • Display version:
    -20 … +60  C (-4 … +140  F)
  • Blind version:
    -20 … +60  C (-4 … +140  F)
  • Custody transfer (CT) version
    -20 … +50 ºC (-4 … +122 ºF)
  • Storage

-40 … +70  C (-40 … +158 F°)

Mechanical load (vibration)

Compact version

18 … 1000 Hz, 3.17 g RMS, sinusoidal in all directions to IEC 68-2-36

19“ insert

1 … 800 Hz, 1 G, sinusoidal in all directions to

IEC 68-2-36

Degree of protection

Compact version

IP67/NEMA 4X/6 to IEC 529 and DIN 40050 (1 mH2O 30 min.)

19“ insert

IP20/NEMA 1 to IEC 529 and DIN 40050

EMC performance

IEC/EN 61326-1 (all environments)

IEC/EN 61326-2-5

Display and keypad

Totalizer

Two eight-digit counters for forward, net or reverse flow

Display

Background illumination with alphanumeric text, 3 x 20 characters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by negative sign

Time constant

Time constant as current output time constant

Design

Enclosure material

  • Compact version

Fiber glass reinforced polyamide; stainless steel AISI 316/1.4436 (IP65)

  • 19“-insert

Standard 19“ insert of aluminium/steel (DIN 41494), width: 21 TE, height: 3 HE

  • Back of panel

IP20/NEMA 1; Aluminium

  • Panel mounting

IP20/NEMA 1 (prepared for IP65/NEMA 2 display side); ABS plastic

  • Wall mounting

IP66/NEMA 4X; ABS plastic

Dimensions

  • Compact version

See dimensional drawings

  • 19“ insert

See dimensional drawings

Weight

  • Compact version

0.75 kg (2 lbs)

  • 19“ insert

See dimensional drawings

Power supply

  • 115 … 230 V AC  +10 % -15 %, 50 … 60 Hz
  • 11 … 30 V DC or 11 … 24 V AC

Power consumption

  • 230 V AC: 17 VA
  • 24 V AC: 9 VA, IN = 380 mA,
    IST = 8 A (30 ms)
  • 12 V DC: 11 W, IN = 920 mA,
    IST = 4 A (250 ms)
  • 24 V DC: 8.4 VA, IN = 350 mA,
    IST = 4 A (10 ms)

IST= 4 A (250 ms):
For solar panel please securestable current supply

Certificates and approvals

General purpose

  • CE (LVD, EMC, PED, RoHS)
  • UL (c-UL-us)

Hazardous area

  • FM, CSA
  • NI Class I Div. 2 Groups A, B, C, D

Custody transfer

  • Cold water: MI-001
  • Chilled water
    • PTB K 7.2 (Germany)
    • OE 12/C 040 (Austria)

Marine
(only for remote version with MAG 5100 W, DN 50 … DN 300)

  • ABS
  • Bureau Veritas
  • DNV-GL
  • Lloyd’s Register

Others

  • CPA (China)
  • EAC (Russia, Belarus, Kazakhstan)
  • KCs (South Korea)

Communication

Standard

  • MAG 5000

HART 5.2 optional

  • MAG 6000

Optional as add-on modules

  • HART 5.2
  • Modbus RTU/RS 485
  • FOUNDATION Fieldbus H1
  • DeviceNet
  • PROFIBUS PA
  • PROFIBUS DP




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    SIEMENS Transmitter MAG5000 / MAG6000

    The MAG 5000 and 6000 are transmitters engineered for high performance, easy installation, commissioning and maintenance. The transmitters evaluate the signals from the SITRANS F M sensors type MAG 1100, MAG 1100 F, MAG 3100, MAG 3100 P and MAG 5100 W.

    Transmitter types:

    • MAG 5000: Max. measuring error ± 0.4 % ± 1 mm/s (incl. sensor)
    • MAG 6000: Max. measuring error ± 0.2 % ± 1 mm/s (incl. sensor, see also sensor specifications) and with additional features such as: “plug & play” add-on bus modules; integrated batch functions.
    Datasheet
    User Manual

    Benefits

    • Superior signal resolution for optimum turn down ratio
    • Digital signal processing with many possibilities
    • Automatic reading of SENSORPROM data for easy commissioning
    • User configurable operation menu with password protection
    • 3 lines, 20 characters display in 11 languages
    • Flow rate in various units
    • Totalizer for forward, reverse and net flow as well as additional information available
    • Multiple functional outputs for process control, minimum configuration with analogue, pulse/frequency and relay output (status, flow direction, limits)
    • Comprehensive self-diagnostic for error indication and error logging (see SITRANS F M diagnostics)
    • Batch control (MAG 6000 only)
    • Custody transfer approval: MI-001 for cold water, PTB K 7.2 and OE12/C 040 for chilled water
    • MAG 6000 with add-on bus modules for HART, FOUNDATION Fieldbus H1, DeviceNet, Modbus RTU/RS485, PROFIBUS PA and DP

    Application

    The SITRANS F M flowmeters are suitable for measuring the flow of almost all electrically conductive liquids, pastes and slurries. The main applications can be found in:

    • Water and waste water
    • Chemical and pharmaceutical industries
    • Food and beverage industries
    • Power generation and utility

    Design

    The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19″ version as a 19″ insert as a base to be used in:

    • 19″ rack systems
    • Front panel mounting IP65/NEMA 2
    • Panel mounting IP20/NEMA 1
    • Wall mounting IP66/NEMA 4X

    Several options on 19″ versions are available such as:

    • Transmitters mounted in safe area for Ex ATEX approved flow sensors (incl. barriers)
    • Transmitters with electrode cleaning unit on request

    Function

    The MAG 5000/6000 are transmitters with a built-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current.

    Further information on connection, mode of operation and installation can be found in the data sheets for the sensors.

    Displays and controls

    Operation of the transmitter can be carried out using:

    • Control and display unit
    • HART communicator
    • PC/laptop and SIMATIC PDM software via HART communication
    • PC/laptop and SIMATIC PDM software using PROFIBUS or Modbus communication

    Technical specifications

    Mode of operation and design

    Measuring principle

    Electromagnetic with pulsed constant field

    Empty pipe

    Detection of empty pipe (special cable required in remote mounted installation)

    Excitation frequency

    Depend on sensor size

    Electrode input impedance

    > 1 x 1014 Ω

    Input

    Digital input

    11 … 30 V DC, Ri = 4. 4 KΩ

    • Activation time

    50 ms

    • Current

    I11 V DC = 2.5 mA, I30 V DC = 7 mA

    Output

    Current output

    • Signal range

    0 … 20 mA or 4 … 20 mA

    • Load

    < 800 Ω

    • Time constant

    0.1 … 30 s, adjustable

    Digital output

    • Frequency

    0 … 10 kHz, 50 % duty cycle (uni/bidirectional)

    • Pulse (active)

    24 V DC, 30 mA, 1 kΩ ≤ Ri ≤ 10 kΩ, short-circuit-protected (power supplied from flowmeter)

    • Pulse (passive)

    3 … 30 V DC, max. 110 mA, 200 Ω ≤ Ri ≤ 10 kΩ powered from connected equipment)

    • Time constant

    0.1 … 30 s, adjustable

    Relay output

    • Time constant

    Changeover relay, same as current output

    • Load

    42 V AC/2 A, 24 V DC/1 A

    Low flow cut off

    0 … 9.9 % of maximum flow

    Galvanic isolation

    All inputs and outputs are galvanically isolated

    Max. measuring error (incl. sensor and zero point) (for detailed accuracy specifications see “System information”)

    • MAG 5000

    ± 0.4 % ± 1 mm/s

    • MAG 6000

    ± 0.2 % ± 1 mm/s

    Rated operation conditions

    Ambient temperature

    • Operation
    • Display version:
      -20 … +60  C (-4 … +140  F)
    • Blind version:
      -20 … +60  C (-4 … +140  F)
    • Custody transfer (CT) version
      -20 … +50 ºC (-4 … +122 ºF)
    • Storage

    -40 … +70  C (-40 … +158 F°)

    Mechanical load (vibration)

    Compact version

    18 … 1000 Hz, 3.17 g RMS, sinusoidal in all directions to IEC 68-2-36

    19“ insert

    1 … 800 Hz, 1 G, sinusoidal in all directions to

    IEC 68-2-36

    Degree of protection

    Compact version

    IP67/NEMA 4X/6 to IEC 529 and DIN 40050 (1 mH2O 30 min.)

    19“ insert

    IP20/NEMA 1 to IEC 529 and DIN 40050

    EMC performance

    IEC/EN 61326-1 (all environments)

    IEC/EN 61326-2-5

    Display and keypad

    Totalizer

    Two eight-digit counters for forward, net or reverse flow

    Display

    Background illumination with alphanumeric text, 3 x 20 characters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by negative sign

    Time constant

    Time constant as current output time constant

    Design

    Enclosure material

    • Compact version

    Fiber glass reinforced polyamide; stainless steel AISI 316/1.4436 (IP65)

    • 19“-insert

    Standard 19“ insert of aluminium/steel (DIN 41494), width: 21 TE, height: 3 HE

    • Back of panel

    IP20/NEMA 1; Aluminium

    • Panel mounting

    IP20/NEMA 1 (prepared for IP65/NEMA 2 display side); ABS plastic

    • Wall mounting

    IP66/NEMA 4X; ABS plastic

    Dimensions

    • Compact version

    See dimensional drawings

    • 19“ insert

    See dimensional drawings

    Weight

    • Compact version

    0.75 kg (2 lbs)

    • 19“ insert

    See dimensional drawings

    Power supply

    • 115 … 230 V AC  +10 % -15 %, 50 … 60 Hz
    • 11 … 30 V DC or 11 … 24 V AC

    Power consumption

    • 230 V AC: 17 VA
    • 24 V AC: 9 VA, IN = 380 mA,
      IST = 8 A (30 ms)
    • 12 V DC: 11 W, IN = 920 mA,
      IST = 4 A (250 ms)
    • 24 V DC: 8.4 VA, IN = 350 mA,
      IST = 4 A (10 ms)

    IST= 4 A (250 ms):
    For solar panel please securestable current supply

    Certificates and approvals

    General purpose

    • CE (LVD, EMC, PED, RoHS)
    • UL (c-UL-us)

    Hazardous area

    • FM, CSA
    • NI Class I Div. 2 Groups A, B, C, D

    Custody transfer

    • Cold water: MI-001
    • Chilled water
      • PTB K 7.2 (Germany)
      • OE 12/C 040 (Austria)

    Marine
    (only for remote version with MAG 5100 W, DN 50 … DN 300)

    • ABS
    • Bureau Veritas
    • DNV-GL
    • Lloyd’s Register

    Others

    • CPA (China)
    • EAC (Russia, Belarus, Kazakhstan)
    • KCs (South Korea)

    Communication

    Standard

    • MAG 5000

    HART 5.2 optional

    • MAG 6000

    Optional as add-on modules

    • HART 5.2
    • Modbus RTU/RS 485
    • FOUNDATION Fieldbus H1
    • DeviceNet
    • PROFIBUS PA
    • PROFIBUS DP




    Technical advice: 03303 / 50 40 66

    Technical advice for this product