The reliability of IRmax has been proven in hot, cold, wet and saline environments, making it ideal for offshore.
IRmax’s unique optical components are treated with a highly durable coating that completely prevents faults due to condensation. As IRmax contains no components for artificially heating optical surfaces, power consumption is dramatically reduced, requiring only 1W of power.
Simple to install
- Compact size – requires less space, effort and time to install
- Various installation options – can be wall mounted, fitted to a 50mm (2 inch) pipe or connected to an auxiliary junction box using a choice of mounting accessories
- Industry standard 4-20mA output – compatible with virtually any control system
- Options for HART communications and RS-485 Modbus
Easy maintenance
- Remote non-intrusive calibration – the remote display can be mounted up to 30 metres from the IRmax and test gas can be applied without requiring direct access to the detector
- Hand-held Intrinsically Safe (I.S) calibrator – IRmax detectors fitted with an I.S barrier module can be checked and calibrated using an I.S handheld display
- STAY-CLIR optics – prevents condensation on optical components
Low cost of ownership
- Low power – only consumes 1W of power, enabling small power supplies and battery back-up systems to be used
- Automatic optical obscuration monitoring – minimal routine maintenance keeps costs down
- Annual proof-test interval
Specifications
IRmax | IRmax with Fixed IR display | IRmax with IS Barrier Module | Remote IR Display | |
Size | 158 x 75 x 57mm (6.2 x 2.9 x 2.3ins) | 230 x 75 x 57mm (9 x 2.9 x 2.3ins) | 261 x 75 x 57mm (2.3 x 2.9 x 2.3ins) | 60 x 54 x 48mm (2.3 x 2.1 x 1.9ins) |
Weight | 1.58kg (3.5lbs) | 2kg (4.4lbs) | 2.4kg (5.3lbs) | 0.2kg (0.4lbs) |
Ingress protection | IP66 | |||
Enclosure material | 316 stainless steel | |||
Power | 12-30 Vdc. < 1W | |||
Connection | One M20 or 1/2” NPT cable gland entry | |||
Electrical output | 4-20mA current sink or source 2mA dirty optics warning (at 75% obscuration, configurable) 0mA detector fault signal (at 90% obscuration, configurable) RS-485 Modbus (optional), HART 7 (optional) |
|||
Operating temperature | -40°C to +75°C (-40°F to 167°F) | |||
Humidity | 0 to 95% RH non-condensing | |||
Pressure range | Atmospheric +/- 10% | |||
Repeatability | +/- 2% FSD | |||
Zero drift | +/- 2% FSD per year maximum | |||
Response time | T-90 <4 seconds | |||
Functional safety | Validation to IEC61508, EN50402 SIL 2 | |||
Approvals | Ex II 2 GD Exd IIC T6 Gb (Tamb -40to+50°C), T4 (Tamb -40to+75°C) Ex tb IIIC T135°C Db (Tamb -40 to +75°C) |
Ex II 2 G Exd ia IIC T4 Gb (Tamb -40to+75°C) |
Ex II 2 GD Exd ia IIC T4 Gb (Tamb -40to+75°C) Ex tb IIIC T135°C Db (Tamb -40 to +40°C) |
|
EMC compliance | Directive 2014/30 EU: EN50270, FCC CFR47 Part 15B, ICES-003 | |||
Zones | Certified for use in Zone 1 & 2. |